Development of a Triple-GEM detector with strip readout and GEMINI chip for X rays and neutron imaging

被引:0
|
作者
Caruggi, F. [1 ,2 ]
Celora, A. [1 ]
Cancelli, S. [1 ,2 ]
Gorini, G. [1 ,2 ,3 ]
Grosso, G. [3 ]
Guiotto, F. [4 ]
Muraro, A. [3 ]
Cippo, E. Perelli [3 ]
Petruzzo, M. [1 ]
Putignano, O. [3 ]
Tardocchi, M. [2 ,3 ]
Giarratana, L. S. [5 ]
Croci, G. [1 ,2 ,3 ]
机构
[1] Univ Milano Bicocca, Dipartimento Fis G Occhialini, Piazza Sci 3, Milan, Italy
[2] INFN Sez Milano Bicocca, Piazza Sci 3, Milan, Italy
[3] Ist Sci & Tecnol Plasmi, CNR, Via Cozzi 53, I-20125 Milan, Italy
[4] Univ Padua, Dipartimento Fis, Via F Marzolo 8, I-35131 Padua, Italy
[5] Osped Bambini Vittore Buzzi, ASST Fatebenefratelli Sacco, Via Castelvetro 32, Milao, Italy
关键词
Inspection with neutrons; Inspection with x-rays; Micropattern gaseous detectors (MSGC; GEM; THGEM; RETHGEM; MHSP; MICROPIC; MICROMEGAS; InGrid; etc); CMOS readout of gaseous detectors;
D O I
10.1088/1748-0221/19/02/C02015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thermal neutron imaging can be a useful tool in the study of the internal structure of an object. The different attenuation properties of the materials with respect to X rays give rise to different interactions and the result is a complementary non-destructive analysis, which can provide important additional information. This technique has been successfully employed in different areas of work, especially in material science and cultural heritage studies. This paper describes the development of a new detection system and its characterization performed with X ray emissions. The system features the use of a gaseous detector, based on the Gas Electron Multiplier technology, and a fully digital electronic readout, with a combination of custom-made ASICs (called GEMINI) and FPGA boards, enabling fast single photon counting. The detector can be thus used directly for X ray imaging, while the addition of a suitable converter in its active volume will allow for detection of neutrons and for reconstruction of their tracks. The readout system is based on a x -y strip structure and features the reconstruction of single events through the center of mass methodology, allowing for accurate tomography, with sub-mm spatial resolution, in combination with sub-ms time resolution and high rate capabilities (up to MHz/mm2).
引用
收藏
页数:7
相关论文
共 30 条
  • [21] X-ray imaging demonstration of glass GEM detector with dynamic time-over-threshold-based readout
    Mitsuya, Y.
    Fujiwara, T.
    Takahashi, H.
    Uesakaa, M.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [22] Study of spatial resolution and X-ray imaging of GEM detector based on APV25 readout electronics system
    Jian S.-Y.
    Hu S.-Y.
    Zhou J.
    Li X.-L.
    Liang H.
    Zhou Y.
    Qi H.-R.
    Li X.-M.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2016, 50 (06): : 1132 - 1136
  • [23] Development of optical switching readout X-ray detector for high-speed imaging
    Kim, Ryun Kyung
    Jeon, Sung Chae
    Kim, Jung-Seok
    Lee, Ho-Jun
    Heo, Duchang
    Cha, Bo Kyung
    Seo, Chang-Woo
    Moon, B. J.
    Yoon, J. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 731 : 305 - 308
  • [24] 2D GEM based imaging detector readout capabilities from perspective of intense soft x-ray plasma radiation
    Chernyshova, M.
    Czarski, T.
    Malinowski, K.
    Melikhov, Y.
    Kasprowicz, G.
    Kowalska-Strzeciwilk, E.
    Linczuk, P.
    Wojenski, A.
    Krawczyk, R. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [25] Development of readout electronics for a high-speed event-driven neutron imaging detector based on Timepix4
    Li, Q.
    Liu, H.
    Cai, D.
    Guo, H.
    Jiang, X.
    Teng, H.
    Wang, K.
    Wang, X.
    Wang, S.
    Sun, Z.
    Zhao, Y.
    Zhou, J.
    JOURNAL OF INSTRUMENTATION, 2025, 20 (02):
  • [26] Development of a fully integrated readout system for high count rate position-sensitive measurements of X-rays using silicon strip detectors
    Grybos, P
    Dabrowski, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 466 - 472
  • [27] A compact imaging system with a CdTe double-sided strip detector for non-destructive analysis using negative muonic X-rays
    Katsuragawa, Miho
    Tampo, Motonobu
    Hamada, Koji
    Harayama, Atsushi
    Miyake, Yasuhiro
    Oshita, Sayuri
    Sato, Goro
    Takahashi, Tadayuki
    Takeda, Shin'ichiro
    Watanabe, Shin
    Yabu, Goro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 140 - 143
  • [28] Non-destructive 3D imaging method using muonic X-rays and a CdTe double-sided strip detector
    I-Huan Chiu
    Shin’ichiro Takeda
    Meito Kajino
    Atsushi Shinohara
    Miho Katsuragawa
    Shunsaku Nagasawa
    Ryota Tomaru
    Goro Yabu
    Tadayuki Takahashi
    Shin Watanabe
    Soshi Takeshita
    Yasuhiro Miyake
    Kazuhiko Ninomiya
    Scientific Reports, 12
  • [29] Non-destructive 3D imaging method using muonic X-rays and a CdTe double-sided strip detector
    Chiu, I-Huan
    Takeda, Shin'ichiro
    Kajino, Meito
    Shinohara, Atsushi
    Katsuragawa, Miho
    Nagasawa, Shunsaku
    Tomaru, Ryota
    Yabu, Goro
    Takahashi, Tadayuki
    Watanabe, Shin
    Takeshita, Soshi
    Miyake, Yasuhiro
    Ninomiya, Kazuhiko
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [30] Development of a high-efficiency high-resolution imaging detector for 30-80 keV X-rays
    Olsen, U. L.
    Badel, X.
    Linnros, J.
    Di Michiel, M.
    Martin, T.
    Schmidt, S.
    Poulsen, H. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 52 - 55