Development of a Triple-GEM detector with strip readout and GEMINI chip for X rays and neutron imaging

被引:0
|
作者
Caruggi, F. [1 ,2 ]
Celora, A. [1 ]
Cancelli, S. [1 ,2 ]
Gorini, G. [1 ,2 ,3 ]
Grosso, G. [3 ]
Guiotto, F. [4 ]
Muraro, A. [3 ]
Cippo, E. Perelli [3 ]
Petruzzo, M. [1 ]
Putignano, O. [3 ]
Tardocchi, M. [2 ,3 ]
Giarratana, L. S. [5 ]
Croci, G. [1 ,2 ,3 ]
机构
[1] Univ Milano Bicocca, Dipartimento Fis G Occhialini, Piazza Sci 3, Milan, Italy
[2] INFN Sez Milano Bicocca, Piazza Sci 3, Milan, Italy
[3] Ist Sci & Tecnol Plasmi, CNR, Via Cozzi 53, I-20125 Milan, Italy
[4] Univ Padua, Dipartimento Fis, Via F Marzolo 8, I-35131 Padua, Italy
[5] Osped Bambini Vittore Buzzi, ASST Fatebenefratelli Sacco, Via Castelvetro 32, Milao, Italy
关键词
Inspection with neutrons; Inspection with x-rays; Micropattern gaseous detectors (MSGC; GEM; THGEM; RETHGEM; MHSP; MICROPIC; MICROMEGAS; InGrid; etc); CMOS readout of gaseous detectors;
D O I
10.1088/1748-0221/19/02/C02015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thermal neutron imaging can be a useful tool in the study of the internal structure of an object. The different attenuation properties of the materials with respect to X rays give rise to different interactions and the result is a complementary non-destructive analysis, which can provide important additional information. This technique has been successfully employed in different areas of work, especially in material science and cultural heritage studies. This paper describes the development of a new detection system and its characterization performed with X ray emissions. The system features the use of a gaseous detector, based on the Gas Electron Multiplier technology, and a fully digital electronic readout, with a combination of custom-made ASICs (called GEMINI) and FPGA boards, enabling fast single photon counting. The detector can be thus used directly for X ray imaging, while the addition of a suitable converter in its active volume will allow for detection of neutrons and for reconstruction of their tracks. The readout system is based on a x -y strip structure and features the reconstruction of single events through the center of mass methodology, allowing for accurate tomography, with sub-mm spatial resolution, in combination with sub-ms time resolution and high rate capabilities (up to MHz/mm2).
引用
收藏
页数:7
相关论文
共 30 条
  • [1] Combined readout of a triple-GEM detector
    Antochi, V. C.
    Baracchini, E.
    Cavoto, G.
    Di Marco, E.
    Marafini, M.
    Mazzitelli, G.
    Pinci, D.
    Renga, F.
    Tomassini, S.
    Voena, C.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [2] Two-dimensional imaging triple-GEM detector with resistive anode readout
    Ju, X. D.
    Dong, M. Y.
    Zhao, Y. C.
    Zhou, C. X.
    Dong, J.
    Zhao, Y. B.
    Zhang, H. Y.
    OuYang, Q.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [3] Optical readout of a triple-GEM detector by means of a CMOS sensor
    Marafini, M.
    Patera, V.
    Pinci, D.
    Sarti, A.
    Sciubba, A.
    Spiriti, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 562 - 564
  • [4] Performance of a triple-GEM detector with capacitive-sharing 3-coordinate (X-Y-U)-strip anode readout
    Gnanvo, Kondo
    Lee, Seung Joon
    Mehl, Bertrand
    de Oliveira, Rui
    Weisenberger, Andrew
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1066
  • [5] Characterization of a triple-GEM position sensitive detector for X-ray fluorescence imaging
    de Souza, Geovane G. A.
    da Luz, Hugo Natal
    X-RAY SPECTROMETRY, 2019, 48 (05) : 387 - 394
  • [6] GEMMA and GEMINI, two dedicated mixed-signal ASICs for Triple-GEM detectors readout
    Pezzotta, A.
    Croci, G.
    Costantini, A.
    De Matteis, M.
    Tagnani, D.
    Corradi, G.
    Murtas, F.
    Gorini, G.
    Baschirotto, A.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [7] A triple-GEM detector with pixel readout for high-rate beam tracking in COMPASS
    Ketzer, B.
    Austregesilo, A.
    Haas, F.
    Konorov, I.
    Kraemer, M.
    Mann, A.
    Nagel, T.
    Paul, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 242 - 244
  • [8] A Triple-GEM Detector with Pixel Readout for High-Rate Beam Tracking in COMPASS
    Nagel, T.
    Austregesilo, A.
    Haas, F.
    Ketzer, B.
    Konorov, I.
    Kraemer, M.
    Mann, A.
    Paul, S.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 1004 - 1008
  • [9] Triple-GEM operated in different gases with highly pixelated readout using MediPix2 chip
    Bamberger, A.
    Desch, K.
    Renz, U.
    Titov, M.
    Vlasov, N.
    Wienemann, P.
    Zwerger, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01): : 157 - 159
  • [10] GEMINI, a CMOS 180 nm Mixed-Signal 16-Channel ASIC for Triple-GEM Detectors Readout
    Pezzotta, A.
    Corradi, G.
    Croci, G.
    De Matteis, M.
    Murtas, F.
    Tagnani, D.
    Gorini, G.
    Baschirotto, A.
    2015 IEEE SENSORS, 2015, : 1134 - 1137