PURPOSE Preoperative evaluation of donor liver volume is indispensable in living donor liver transplantation to ensure sufficient residual liver and graft -to -recipient weight ratio. This study aims to evaluate the accuracy of two computed tomography (CT) volumetry programs, an interactive manual and a semi -automated one, in the preoperative estimation of the right lobe graft weight. METHODS One hundred and nine right liver lobe living donors between January 2008 and January 2020 were enrolled in this retrospective study. Two radiologists measured the liver graft volumes independently using manual and semi -automated CT volumetry, and the interaction time was recorded. Actual graft weight (AGW) measured intraoperatively served as the reference standard. The paired samples t -test was used to compare the estimated graft weight (EGW) and the AGW. Inter -user and inter -method agreements were assessed with Bland-Altman plots. RESULTS Both manual and semi -automated CT volumetry significantly overestimated the graft weight (EGW manual: 893 +/- 155 mL vs. AGW manual: 787 +/- 128 g, P < 0.001, EGW semi -automated: 879 +/- 143 mL vs. AGW semi -automated, P < 0.001). The junior radiologist measured higher volumes than the senior radiologist with either method (P < 0.001). The Bland-Altman analysis revealed mean difference and standard deviation for inter -method agreement of 7 +/- 48 cc for the senior radiologist, and 34 +/- 54 cc for the junior radiologist. The mean difference and standard deviation for inter -method agreement was 63 +/- 59 cc in manual volumetry and 22 +/- 38 cc in semi -automated volumetry. The mean interaction time was 27.3 +/- 14.2 min for manual volumetry and 6.8 +/- 1.4 min for semi -automated volumetry (P < 0.001). CONCLUSION Both manual and semi -automated CT volumetry significantly overestimated the right liver graft weight, while semi -automated volumetry significantly reduced the interaction time.
引用
收藏
页码:3 / 8
页数:6
相关论文
共 15 条
  • [1] Resection plane-dependent error in computed tomography volumetry of the right hepatic lobe in living liver donors
    Kwon, Heon-Ju
    Kim, Kyoung Won
    Kim, Bohyun
    Kim, So Yeon
    Lee, Chul Seung
    Lee, Jeongjin
    Song, Gi Won
    Lee, Sung Gyu
    CLINICAL AND MOLECULAR HEPATOLOGY, 2018, 24 (01) : 54 - 60
  • [2] Vascular reconstruction and outcomes of adult-to-adult right lobe living donor liver transplantations: A single-center experience in Vietnam
    Le Van Thanh
    Vu Van Quang
    Dao Tan Luc
    Le Van Loi
    Ho Van Linh
    Vu Ngoc Tuan
    Le Trung Hieu
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2021, 36 : 281 - 282
  • [3] Respiratory Complications Among Living Liver Donors: A Single-Center Retrospective Observational Study
    Shorbagy, Mohammed S.
    Saleh, Mohammed
    Elbeialy, Marwa A. K.
    Elsaid, Kamal
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2020, 18 (04) : 474 - 480
  • [4] Surgical Outcome of Right Liver Donors in Living Donor Liver Transplantation: Single-Center Experience with 500 Cases
    Kim, Say-June
    Na, Gun-Hyung
    Choi, Ho-Joong
    Yoo, Young-Kyung
    Kim, Dong-Goo
    JOURNAL OF GASTROINTESTINAL SURGERY, 2012, 16 (06) : 1160 - 1170
  • [5] Surgical Outcome of Right Liver Donors in Living Donor Liver Transplantation: Single-Center Experience with 500 Cases
    Say-June Kim
    Gun-Hyung Na
    Ho-Joong Choi
    Young-Kyung Yoo
    Dong-Goo Kim
    Journal of Gastrointestinal Surgery, 2012, 16 : 1160 - 1170
  • [6] Postoperative Complications in Living Liver Donors: A Retrospective Study, Single-Center Experience in Saudi Arabia
    Althonaian, Nouf Abdulaziz
    Alsaiari, Alanoud Saleh
    Almanea, Weaam Ahmed
    Alsubaie, Norah Jezaa
    Almuharimi, Awatif Ali
    Althubaiti, Alaa
    Altamimi, Abdulrahman Rashed
    Abdullah, Khalid Omer
    Ohali, Wael Abdulaziz
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2019, 30 (02) : 359 - 364
  • [7] Urgent adult-to-adult right lobe living donor liver transplantation for acute liver failure; A single center experience from Turkey
    Karasu, Zeki
    Akyildiz, Murat
    Zeytunlu, Murat
    Noyan, Aysin
    Yuzer, Yidiray
    Tokat, Yaman
    Kilic, Murat
    HEPATO-GASTROENTEROLOGY, 2007, 54 (75) : 810 - 813
  • [8] Surgical site infection and risk factors following right lobe living donor liver transplantation in adults: A single-center prospective cohort study
    Aktas, Aydin
    Kayaalp, Cuneyt
    Gunes, Orgun
    Gokler, Cihan
    Uylas, Ufuk
    Cicek, Egemen
    Ersoy, Yasemin
    Kose, Adem
    Bayindir, Yasar
    Aydin, Cemalettin
    Yilmaz, Sezai
    TRANSPLANT INFECTIOUS DISEASE, 2019, 21 (06)
  • [9] Adult-to-adult right lobe graft living donor liver transplantation for acute-on-chronic liver failure: a single-centre retrospective study in Vietnam
    Vu, Quang V.
    Le, Thanh V.
    Le, Hieu T.
    Nguyen, Anh H. N.
    Nguyen, Duy T.
    ANNALS OF MEDICINE AND SURGERY, 2024, 86 (03): : 1261 - 1267
  • [10] Hemodynamic alterations in anterior segment of liver graft after right-lobe living-donor liver transplantation: computed tomography perfusion imaging findings
    Qian, Li Jun
    Zhuang, Zhi Guo
    Cheng, Yu Fan
    Xia, Qiang
    Zhang, Jian Jun
    Xu, Jian Rong
    ABDOMINAL IMAGING, 2010, 35 (05): : 522 - 527