Design of Dual-Notch-Filter-Based Controllers for Enhancing the Dynamic Response of Universal Single-Phase Grid-Connected Power Converters

被引:0
作者
Borafker, Sahar [1 ]
Strajnikov, Pavel [1 ]
Kuperman, Alon [1 ]
机构
[1] Ben Gurion Univ Negev, Sch Elect & Comp Engn, Appl Energy Lab, IL-8410501 Beer Sheva, Israel
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 18期
基金
以色列科学基金会;
关键词
single-phase grid-connected converter; transient response; total harmonic distortion; notch filter; control system; LINK VOLTAGE CONTROL; PFC; PERFORMANCE; CANCELLATION; CAPACITANCE; MODULATION; QUALITY; SCHEME;
D O I
10.3390/app131810144
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Trade-off between transient response and grid-side current quality is a well-known issue of single-phase mains-connected power converters. A dual-loop control structure (usually based on PI or type-II controllers) is typically employed in such systems to regulate the DC link voltage to a constant reference (in order to maintain power balance) while forcing the grid-side current to have a specific shape (in order to comply with power quality requirements). Introducing notch term/s (tuned to certain multiple/s of the mains base frequency) into one of the loops allows either for the improvement of the dynamic performance without worsening the total harmonic distortion of grid-side current or for the enhancement of the current quality without impairing the dynamic response. Since the maximum tolerable value of total harmonic distortion is typically imposed by a certain power quality standard, it is desirable to enhance the transient response of the power converter system as much as possible while keeping the total harmonic distortion at the maximum allowed value. However, universal off-grid operating power conversion systems must support both 50 Hz and 60 Hz mains; consequently, tuning the notch term/s to 50 Hz multiple/s would not be sufficient for a 60 Hz mains operation and vice-versa. Consequently, this work examines the possibility of introducing a dual-notch term into the control loop in order to cover both above-mentioned base frequencies. It is demonstrated that under typical base frequency uncertainty values, the performances of dual-notch terms are nearly decoupled so that the term tuned to a 50 Hz frequency (and optionally to its multiples) has nearly no influence at a 60 Hz mains operation and vice-versa. Consequently, the methodology allows for the improvement of the dynamics of universal grid-connected power converters without total harmonic distortion (THD) deterioration. A stability analysis of the proposed control structure is carried out and quantitative design guidelines, allowing for the attainment of an optimized dynamic response for a given maximum tolerable total harmonic distortion, minimum allowed phase margin and a certain base frequency uncertainty, are established. It is shown that a DC link voltage loop bandwidth of 52 Hz may be attained while keeping the grid-side current THD below 5%. Simulations and experimental results support well the proposed design methodology.
引用
收藏
页数:24
相关论文
共 57 条
  • [1] Unity Power Factor Operation in Microgrid Applications Using Fuzzy Type 2 Nested Controllers
    Awad, Hilmy
    Ibrahim, Amr M.
    De Santis, Michele
    Bayoumi, Ehab H. E.
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (09):
  • [2] Digital Adaptive Frequency Modulation for Bidirectional DC-DC Converter
    Baek, Jong-Bok
    Choi, Woo-In
    Cho, Bo-Hyung
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (11) : 5167 - 5176
  • [3] Borafker S., 2023, P 15 INT C EL COMM S
  • [4] Unity power factor Converter based on a Fuzzy controller and Predictive Input Current
    Bouafassa, Amar
    Rahmani, Lazhar
    Kessal, Abdelhalim
    Babes, Badreddine
    [J]. ISA TRANSACTIONS, 2014, 53 (06) : 1817 - 1821
  • [5] Simple digital control improving dynamic performance of power factor preregulators
    Buso, S
    Mattavelli, P
    Rossetto, L
    Spiazzi, G
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (05) : 814 - 823
  • [6] Single-phase power line conditioning with unity power factor under distorted utility voltage
    Castellan, Simone
    Buja, Giuseppe
    Menis, Roberto
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 121
  • [7] PV-Powered Charging Station with Energy Cost Optimization via V2G Services
    Cheikh-Mohamad, Saleh
    Celik, Berk
    Sechilariu, Manuela
    Locment, Fabrice
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (09):
  • [8] An analog implementation to improve load transient response of PFC pre-regulators
    Cheung, Martin K. H.
    Chow, Martin H. L.
    Tse, Chi K.
    [J]. INTELEC 07 - 29TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, VOLS 1 AND 2, 2007, : 848 - 855
  • [9] Control method for improving the response of single-phase continuous conduction mode boost power factor correction converter
    Chiang, Hsuang-Chang
    Lin, Faa-Jeng
    Chang, Jin-Kuan
    Chen, Kun-Feng
    Chen, Yi-Lun
    Liu, Ke-Chih
    [J]. IET POWER ELECTRONICS, 2016, 9 (09) : 1792 - 1800
  • [10] Digital Plug-In Repetitive Controller for Single-Phase Bridgeless PFC Converters
    Cho, Younghoon
    Lai, Jih-Sheng
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) : 165 - 175