A PORTABLE AIR QUALITY MONITOR BASED ON LOW-COST SENSORS

被引:1
作者
Tasic, Visa M. [1 ]
Bozilov, Aca, V [2 ]
Misic, Nikola Z. [2 ]
Topalovic, Dusan B. [3 ]
Randjelovic, Ivana S. [4 ]
Mirkov, Nikola S. [3 ]
Kamenovic, Vladan V. [1 ]
机构
[1] Min & Met Inst, Bor, Serbia
[2] Univ Nis, Fac Occupat Safety, Nish, Serbia
[3] Univ Belgrade, Vinca Inst Nucl Sci, Natl Inst Republ Serbia, Belgrade, Serbia
[4] Univ Nis, Fac Elect Engn, Nish, Serbia
来源
THERMAL SCIENCE | 2023年 / 27卷 / 3B期
关键词
air quality; monitoring; low-cost; particulate matter; CO; sensors; PARTICULATE; ASSOCIATIONS; MORTALITY; EXPOSURE; FINE;
D O I
10.2298/TSCI220118107T
中图分类号
O414.1 [热力学];
学科分类号
摘要
National systems of automatic air quality monitoring are based on automatic measuring instruments that are installed in stationary air quality monitoring stations. Substantial financial resources are required for the procurement, installation, calibration, and maintenance of such measuring devices. For this reason, existing national and local air quality monitoring networks are not able to provide a high temporal and spatial resolution of measurement results. In the last decade, as a possible alternative to the conventional approach to air quality monitoring, real-time monitoring systems using low-cost sensors and sensor platforms have begun to be applied. This paper describes the basic characteristics of a portable air quality monitor PAQMAN 2020 based on low-cost sensors. Part of the results of comparative measurements of this device with the reference instruments is presented in the paper.
引用
收藏
页码:2309 / 2319
页数:11
相关论文
共 27 条
[1]   Particulate matter and daily mortality and hospital admissions in the west midlands conurbation of the United Kingdom: associations with fine and coarse particles, black smoke and sulphate [J].
Anderson, HR ;
Bremner, SA ;
Atkinson, RW ;
Harrison, RM ;
Walters, S .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2001, 58 (08) :504-510
[2]  
[Anonymous], About Us
[3]  
[Anonymous], About us
[4]  
[Anonymous], 2022, About us
[5]   Associations between indoor CO2 concentrations and sick building syndrome symptoms in US office buildings:: An analysis of the 1994-1996 BASE study data [J].
Apte, MG ;
Fisk, WJ ;
Daisey, JM .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (04) :246-257
[6]   Evaluation of Low-Cost Sensors for Ambient PM2.5 Monitoring [J].
Badura, Marek ;
Batog, Piotr ;
Drzeniecka-Osiadacz, Anetta ;
Modzel, Piotr .
JOURNAL OF SENSORS, 2018, 2018
[7]   A review and analysis of personal and ambient PM2.5 measurements: Implications for epidemiology studies [J].
Boomhower, Steven R. ;
Long, Christopher M. ;
Li, Wenchao ;
Manidis, Tatiana D. ;
Bhatia, Arunika ;
Goodman, Julie E. .
ENVIRONMENTAL RESEARCH, 2022, 204
[8]   Effects of travel mode on exposures to particulate air pollution [J].
Briggs, David J. ;
de Hoogh, Kees ;
Morris, Chloe ;
Gulliver, John .
ENVIRONMENT INTERNATIONAL, 2008, 34 (01) :12-22
[9]   Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates? [J].
Castell, Nuria ;
Dauge, Franck R. ;
Schneider, Philipp ;
Vogt, Matthias ;
Lerner, Uri ;
Fishbain, Barak ;
Broday, David ;
Bartonova, Alena .
ENVIRONMENT INTERNATIONAL, 2017, 99 :293-302
[10]  
cdn.instructables, US