Comparison between ultrasound and chest X-ray to confirm central venous catheter tip position

被引:2
作者
de Man, Leoni [1 ]
Wentzel, Mari [2 ]
van Rooyen, Cornel [3 ]
Turton, Edwin [1 ]
机构
[1] Univ Free State, Fac Hlth Sci, Dept Anaesthesiol, Bloemfontein, South Africa
[2] Univ Free State, Fac Hlth Sci, Dept Clin Imaging Sci, Bloemfontein, South Africa
[3] Univ Free State, Fac Hlth Sci, Dept Biostat, Bloemfontein, South Africa
来源
SA JOURNAL OF RADIOLOGY | 2023年 / 27卷 / 01期
关键词
central venous catheter; position; chest X-ray; ultrasound; peri-operative; CVC; CXR; TENSION PNEUMOTHORAX; INSERTION; BUBBLE; RADIOGRAPHY; PLACEMENT;
D O I
10.4102/sajr.v27i1.2587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Mechanical central venous catheter (CVC) placement complications are mostly malposition or iatrogenic pneumothorax. Verification of catheter position by chest X-ray (CXR) is usually performed postoperatively.Objectives: This prospective observational study assessed the diagnostic accuracy of peri-operative ultrasound and a 'bubble test' to detect malposition and pneumothorax.Method: Sixty-one patients undergoing peri-operative CVC placement were included. An ultrasound protocol was used to directly visualise the CVC, perform the 'bubble test' and assess for the presence of pneumothorax. The time from agitated saline injection to visualisation of microbubbles in the right atrium was evaluated to determine the correct position of the CVC. The time required to perform the ultrasound assessment was compared to that of conducting the CXR.Results: Chest X-ray identified 12 (19.7%) malpositions while ultrasound identified 8 (13.1%). Ultrasound showed a sensitivity of 0.85 (95% confidence interval [CI]: 0.72 to 0.93) and a specificity of 0.5 (95% CI: 0.16 to 0.84). The positive and negative predictive values were 0.92 (95% CI: 0.80 to 0.98) and 0.33 (95% CI: 0.10 to 0.65), respectively. No pneumothorax was identified on ultrasound and CXR. The median time for ultrasound assessment was significantly shorter at 4 min (interquartile range [IQR]: 3-6 min), compared to performing a CXR that required a median time of 29 min (IQR: 18-56 min) (p < 0.0001).Conclusion: This study showed that ultrasound produced a high sensitivity and moderate specificity in detecting CVC malposition.Contribution: Ultrasound can improve efficiency when used as a rapid bedside screening test to detect CVC malposition.
引用
收藏
页数:8
相关论文
共 37 条
[1]   Diagnostic Accuracy of Central Venous Catheter Confirmation by Bedside Ultrasound Versus Chest Radiography in Critically III Patients: A Systematic Review and Meta-Analysis [J].
Ablordeppey, Enyo A. ;
Drewry, Anne M. ;
Beyer, Alexander B. ;
Theodoro, Daniel L. ;
Fowler, Susan A. ;
Fuller, Brian M. ;
Carpenter, Christopher R. .
CRITICAL CARE MEDICINE, 2017, 45 (04) :715-724
[2]   Mechanical complications after central venous catheterisation in the ultrasound-guided era: a prospective multicentre cohort study [J].
Adrian, Maria ;
Borgquist, Ola ;
Kroger, Tina ;
Linne, Erik ;
Bentzer, Peter ;
Spangfors, Martin ;
Akeson, Jonas ;
Holmstrom, Anders ;
Linner, Rikard ;
Kander, Thomas .
BRITISH JOURNAL OF ANAESTHESIA, 2022, 129 (06) :843-850
[3]   Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis [J].
Alrajab, Saadah ;
Youssef, Asser M. ;
Akkus, Nuri I. ;
Caldito, Gloria .
CRITICAL CARE, 2013, 17 (05)
[4]  
[Anonymous], 2016, Anesth Pain Med, DOI [10.5812/aapm.38834, DOI 10.5812/AAPM.38834]
[5]  
Blans MJ, 2016, NETH J MED, V74, P353
[6]   Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization [J].
Brass, Patrick ;
Hellmich, Martin ;
Kolodziej, Laurentius ;
Schick, Guido ;
Smith, Andrew F. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (01)
[7]   Radiologist variability in assessing the position of the cavoatrial junction on chest radiographs [J].
Chan, Tze Y. ;
England, Andrew ;
Meredith, Sara M. ;
McWilliams, Richard G. .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1065)
[8]   Use of Contrast-Enhanced Ultrasound for Confirmation of Central Venous Catheter Placement: Systematic Review and Meta-analysis [J].
Chebl, Ralph Bou ;
Kiblawi, Shafeek ;
El Khuri, Christopher ;
El Hajj, Nadine ;
Bachir, Rana ;
Aoun, Roni ;
Abou Dagher, Gilbert .
JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (12) :2503-2510
[9]   The bubble study: ultrasound confirmation of central venous catheter placement [J].
Duran-Gehring, Petra E. ;
Guirgis, Faheem W. ;
McKee, Kristin C. ;
Goggans, Susan ;
Huynh Tran ;
Kalynych, Colleen J. ;
Wears, Robert L. .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (03) :315-319
[10]  
Ebrahimi Ali, 2014, Tanaffos, V13, P29