Noise exposure during robot-assisted total knee arthroplasty

被引:8
作者
Tim, Hoenecke [1 ,4 ]
Michael, Schwarze [2 ]
Matthias, Wangenheim [3 ]
Savov, Peter [1 ]
Henning, Windhagen [1 ]
Max, Ettinger [1 ]
机构
[1] Hannover Med Sch, Dept Orthoped Surg, Anna Von Borries Str 1-7, D-30625 Hannover, Germany
[2] Hannover Med Sch, Lab Biomech & Biomat, D-30625 Hannover, Germany
[3] Leibniz Univ Hannover, Inst Dynam & Vibrat, Welfengarten 1, D-30167 Hannover, Germany
[4] Hahnenstr 13, D-30167 Hannover, Germany
关键词
Total knee arthroplasty; Noise-inducing hearing loss; Gonarthrosis; Computer-assisted surgery; Robot-assisted surgery occupational noise;
D O I
10.1007/s00402-022-04454-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of the study was to examine the noise exposure for operating theater staff during total knee arthroplasty (TKA) with three different robot systems. There is already evidence that noise exposure during TKA performed manually exceeds recommended guidelines for occupational noise. Therefore, if surgical staff is exposed to it for several years, the development of noise-inducing hearing loss (NIHL) is significantly increased. To investigate the noise exposure during robot-assisted TKA, the study measured the average noise and the peak sound pressure during TKA with MAKO robot (Stryker, Kalamazoo, Michigan, United States), NAVIO robot (Smith and Nephew, London, Great Britain), and CORI robot (Smith and Nephew, London, Great Britain) using a class 1 sound level meter. Each robot system exceeds the recommended guidelines from the national institute for occupational safety and health. While the MAKO robot had the highest average sound level (93.18 dB(A)) of the three robot systems (NAVIO: 88.88 dB(A), CORI: 89.38 dB(A)), the peak sound level was the highest with the NAVIO Robot (134.48 dB(C)) compared to the MAKO Robot (128.98 dB(C)) and CORI robot (126.48 dB(C)). Robot-assisted TKA is a risk factor for NIHL, like manually performed TKA. Further research for decreasing the noise exposure during TKA is needed to minimize the hearing loss in operating theater staff.
引用
收藏
页码:2813 / 2819
页数:7
相关论文
共 50 条
  • [41] Alignment in knee flexion position during navigation-assisted total knee arthroplasty
    Yang, Jae-Hyuk
    Dahuja, Anshul
    Kim, Jin-Kak
    Yun, Se-Hyeok
    Yoon, Jung-Ro
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2422 - 2429
  • [42] Study on the correlation between early three-dimensional gait analysis and clinical efficacy after robot-assisted total knee arthroplasty
    He, Rui
    Xiong, Ran
    Sun, Mao-Lin
    Yang, Jun-Jun
    Chen, Hao
    Yang, Peng-Fei
    Yang, Liu
    [J]. CHINESE JOURNAL OF TRAUMATOLOGY, 2023, 26 (02) : 83 - 93
  • [43] Computer- and Robot-Assisted Total Knee Replacement: Analysis of a New Surgical Procedure
    M. Martelli
    M. Marcacci
    L. Nofrini
    F. La Palombara
    A. Malvisi
    F. Iacono
    P. Vendruscolo
    M. Pierantoni
    [J]. Annals of Biomedical Engineering, 2000, 28 : 1146 - 1153
  • [44] Study on the correlation between early three-dimensional gait analysis and clinical efficacy after robot-assisted total knee arthroplasty
    He Rui
    Xiong Ran
    Sun Mao-Lin
    Yang Jun-Jun
    Chen Hao
    Yang Peng-Fei
    Yang Liu
    [J]. 中华创伤杂志英文版, 2023, 26 (02)
  • [45] The Knee Adduction Moment During Gait is Associated With the Adduction Angle Measured During Computer-Assisted Total Knee Arthroplasty
    Roda, Richard D.
    Wilson, Janie L. Astephen
    Wilson, David A. J.
    Richardson, Glen
    Dunbar, Michael J.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 1244 - 1250
  • [46] Computer-assisted patellar resection for total knee arthroplasty
    Fu, C.
    Wai, J.
    Lee, E.
    Myden, C.
    Batuyong, E.
    Hutchison, C. R.
    Anglin, C.
    [J]. COMPUTER AIDED SURGERY, 2012, 17 (01) : 21 - 28
  • [47] The Accuracy of CT-Based Three-Dimensional Templating in Predicting Implant Sizes in Patients Undergoing Robot-Assisted Total Knee Arthroplasty
    Adkar, Neeraj
    Patil, Mangesh
    Vaidya, Swapnil
    Kumbar, Rajendra
    Kerhalkar, Ravi
    Mote, Girish
    Thareja, Satwik
    Sadalagi, Prajwal
    Bajwa, Supreet
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2024, 58 (10) : 1388 - 1394
  • [48] Intraoperative passive knee kinematics during total knee arthroplasty surgery
    Young, Kathryn L.
    Dunbar, Michael J.
    Richardson, Glen
    Wilson, Janie L. Astephen
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (11) : 1611 - 1619
  • [49] In vivo patellar kinematics during total knee arthroplasty
    Anglin, Carolyn
    Ho, Karen C. T.
    Briard, Jean-Louis
    De Lambilly, Charles
    Plaskos, Christopher
    Nodwell, Eric
    Stindel, Eric
    [J]. COMPUTER AIDED SURGERY, 2008, 13 (06) : 377 - 391
  • [50] MAKO robot-assisted total knee arthroplasty cannot reduce the aggravation of ankle varus incongruence after genu varus correction ≥ 10°: a radiographic assessment
    Gang Jin
    Yongyong Fan
    Lingjun Jiang
    Zhongyi Chen
    Chenglong Wang
    [J]. BMC Musculoskeletal Disorders, 24