Noise exposure during robot-assisted total knee arthroplasty

被引:8
|
作者
Tim, Hoenecke [1 ,4 ]
Michael, Schwarze [2 ]
Matthias, Wangenheim [3 ]
Savov, Peter [1 ]
Henning, Windhagen [1 ]
Max, Ettinger [1 ]
机构
[1] Hannover Med Sch, Dept Orthoped Surg, Anna Von Borries Str 1-7, D-30625 Hannover, Germany
[2] Hannover Med Sch, Lab Biomech & Biomat, D-30625 Hannover, Germany
[3] Leibniz Univ Hannover, Inst Dynam & Vibrat, Welfengarten 1, D-30167 Hannover, Germany
[4] Hahnenstr 13, D-30167 Hannover, Germany
关键词
Total knee arthroplasty; Noise-inducing hearing loss; Gonarthrosis; Computer-assisted surgery; Robot-assisted surgery occupational noise;
D O I
10.1007/s00402-022-04454-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of the study was to examine the noise exposure for operating theater staff during total knee arthroplasty (TKA) with three different robot systems. There is already evidence that noise exposure during TKA performed manually exceeds recommended guidelines for occupational noise. Therefore, if surgical staff is exposed to it for several years, the development of noise-inducing hearing loss (NIHL) is significantly increased. To investigate the noise exposure during robot-assisted TKA, the study measured the average noise and the peak sound pressure during TKA with MAKO robot (Stryker, Kalamazoo, Michigan, United States), NAVIO robot (Smith and Nephew, London, Great Britain), and CORI robot (Smith and Nephew, London, Great Britain) using a class 1 sound level meter. Each robot system exceeds the recommended guidelines from the national institute for occupational safety and health. While the MAKO robot had the highest average sound level (93.18 dB(A)) of the three robot systems (NAVIO: 88.88 dB(A), CORI: 89.38 dB(A)), the peak sound level was the highest with the NAVIO Robot (134.48 dB(C)) compared to the MAKO Robot (128.98 dB(C)) and CORI robot (126.48 dB(C)). Robot-assisted TKA is a risk factor for NIHL, like manually performed TKA. Further research for decreasing the noise exposure during TKA is needed to minimize the hearing loss in operating theater staff.
引用
收藏
页码:2813 / 2819
页数:7
相关论文
共 50 条
  • [1] Noise exposure during robot-assisted total knee arthroplasty
    Tim Hönecke
    Michael Schwarze
    Matthias Wangenheim
    Peter Savov
    Henning Windhagen
    Max Ettinger
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 2813 - 2819
  • [2] Robot-assisted total knee arthroplasty in haemophilic arthropathy
    Kim, K. -I.
    Kim, D. -K.
    Juh, H. -S.
    Khurana, S.
    Rhyu, K. -H.
    HAEMOPHILIA, 2016, 22 (03) : 446 - 452
  • [3] Robot-assisted Minimally Invasive Total Knee Arthroplasty System
    Zhang Y.
    Li W.
    Chen J.
    Song G.
    Qi Y.
    Xu Y.
    Wang J.
    Jiqiren/Robot, 2021, 43 (04): : 386 - 394
  • [4] Comparative analysis of radiation exposure in robot-assisted total knee arthroplasty using popular robotic systems
    Saad, Ahmed
    Mayne, Alistair
    Pagkalos, Joseph
    Ollivier, Matthieu
    Botchu, Rajesh
    Davis, Edward
    Sharma, Akash
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [5] Registration of the tibia in robot-assisted total knee arthroplasty using surface matching
    Denis, K
    Van Ham, G
    Vander Sloten, J
    Van Audekercke, R
    Van der Perre, G
    De Schutter, J
    Bellemans, J
    Fabry, G
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 664 - 669
  • [6] Access to robot-assisted total knee arthroplasty varies significantly by race/ethnicity
    Schmerler, Jessica
    Bergstein, Victoria E.
    Kagabo, Whitney
    Khanuja, Harpal S.
    Oni, Julius K.
    Hegde, Vishal
    KNEE SURGERY & RELATED RESEARCH, 2025, 37 (01)
  • [7] Initial Learning Curve for Robot-Assisted Total Knee Arthroplasty in a Dedicated Orthopedics Center
    Dragosloveanu, Serban
    Petre, Mihnea-Alexandru
    Capitanu, Bogdan Sorin
    Dragosloveanu, Christiana Diana Maria
    Cergan, Romica
    Scheau, Cristian
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [8] Characteristics of Resection Parameters in Robot-Assisted Total Knee Arthroplasty With the Ligament Balancing Workflow
    Wei, Qing-Da
    An, Hao-Ming
    Gu, Wang
    Sun, Wei
    Li, Rui
    Chai, Wei
    ORTHOPAEDIC SURGERY, 2025, : 841 - 847
  • [9] Effect of Posterior Cruciate Ligament Resection on Gap Balancing in Robot-assisted Total Knee Arthroplasty
    Zhu, Kechao
    Wang, Jiaxing
    Dai, Huiyong
    Xi, Yan
    Wang, Qiaojie
    Zhang, Xianlong
    Wang, Qi
    ORTHOPAEDIC SURGERY, 2024, 16 (08) : 1929 - 1938
  • [10] Early experiences with robot-assisted total knee arthroplasty using the DigiMatch™ ROBODOC® surgical system
    Liow, Ming Han Lincoln
    Chin, Pak Lin
    Tay, Keng Jin Darren
    Chia, Shi Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    SINGAPORE MEDICAL JOURNAL, 2014, 55 (10) : 529 - 534