MRI Gadolinium-Based Contrast Media: Meeting Radiological, Clinical, and Environmental Needs

被引:1
作者
Bendszus, Martin [1 ]
Laghi, Andrea [2 ]
Munuera, Josep [3 ,4 ]
Tanenbaum, Lawrence N. [5 ]
Taouli, Bachir [6 ]
Thoeny, Harriet C. [7 ,8 ,9 ]
机构
[1] Univ Hosp Heidelberg, Dept Neuroradiol, Heidelberg, Germany
[2] Sapienza Univ Rome, Sant Andrea Univ Hosp, Fac Med & Psychol, Dept Med Surg Sci & Translat Med, Rome, Italy
[3] Inst Recerca St Pau, Ctr CERCA, Artificial Intelligence & Imaging Guided Therapy R, Adv Med Imaging, Barcelona, Spain
[4] Hosp Santa Creu i St Pau, Diagnost Imaging Dept, Barcelona, Spain
[5] RadNet Inc, New York, NY USA
[6] Icahn Sch Med Mt Sinai, Dept Diagnost Mol & Intervent Radiol, New York, NY USA
[7] Fribourg Cantonal Hosp, Dept Diagnost & Intervent Radiol, Fribourg, Switzerland
[8] Univ Fribourg, Fac Med, Fribourg, Switzerland
[9] Chem Pensionnats 2-6, CH-1752 Fribourg, Switzerland
关键词
magnetic resonance imaging; gadolinium-based contrast agents; gadopiclenol; AGENTS; RELAXIVITY; BRAIN; ANGIOGRAPHY; FUTURE; DEPOSITION; STABILITY; FOOTPRINT; HISTORY; QUALITY;
D O I
10.1002/jmri.29181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gadolinium-based contrast agents (GBCAs) are routinely used in magnetic resonance imaging (MRI). They are essential for choosing the most appropriate medical or surgical strategy for patients with serious pathologies, particularly in oncologic, inflammatory, and cardiovascular diseases. However, GBCAs have been associated with an increased risk of nephrogenic systemic fibrosis in patients with renal failure, as well as the possibility of deposition in the brain, bones, and other organs, even in patients with normal renal function. Research is underway to reduce the quantity of gadolinium injected, without compromising image quality and diagnosis. The next generation of GBCAs will enable a reduction in the gadolinium dose administered. Gadopiclenol is the first of this new generation of GBCAs, with high relaxivity, thus having the potential to reduce the gadolinium dose while maintaining good in vivo stability due to its macrocyclic structure. High-stability and high-relaxivity GBCAs will be one of the solutions for reducing the dose of gadolinium to be administered in clinical practice, while the development of new technologies, including optimization of MRI acquisitions, new contrast mechanisms, and artificial intelligence may help reduce the need for GBCAs. Future solutions may involve a combination of next-generation GBCAs and image-processing techniques to optimize diagnosis and treatment planning while minimizing exposure to gadolinium.
引用
收藏
页码:1774 / 1785
页数:12
相关论文
共 95 条
  • [1] ACR Committee on Drugs and Contrast Media, 2023, ACR Manual On Contrast Media
  • [2] Nephrogenic Systemic Fibrosis: Change in Incidence Following a Switch in Gadolinium Agents and Adoption of a Gadolinium Policy-Report from Two US Universities
    Altun, Ersan
    Martin, Diego R.
    Wertman, Rebecca
    Lugo-Somolinos, Aida
    Fuller, Edwin R., III
    Semelka, Richard C.
    [J]. RADIOLOGY, 2009, 253 (03) : 689 - 696
  • [3] Can Deep Learning Replace Gadolinium in Neuro-Oncology? A Reader Study
    Ammari, Samy
    Bone, Alexandre
    Balleyguier, Corinne
    Moulton, Eric
    Chouzenoux, Emilie
    Volk, Andreas
    Menu, Yves
    Bidault, Francois
    Nicolas, Francois
    Robert, Philippe
    Rohe, Marc-Michel
    Lassau, Nathalie
    [J]. INVESTIGATIVE RADIOLOGY, 2022, 57 (02) : 99 - 107
  • [4] [Anonymous], 2022, MAGNETIC RESONANCE I
  • [5] [Anonymous], 2019, HLTH RISKS MRIS GAD
  • [6] [Anonymous], 2017, SAF ANN
  • [7] [Anonymous], 2022, ACR MAN CONTR MED
  • [8] [Anonymous], 2007, FDA REQ BOX WARN CON
  • [9] [Anonymous], 2009, EUR MED AG MAK REC M
  • [10] [Anonymous], NAT LIB MED US