Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode

被引:1
|
作者
Manh, Tran Duc [1 ]
Nguyen, Vo Thang [1 ]
Duyen, Vu Thi [1 ]
Nga, Nguyen Thi Thy [1 ]
Man, Nguyen Quang [2 ]
Thoa, Pham Thi Huyen [3 ]
Trinh, Le Huu [4 ]
Khieu, Dinh Quang [5 ]
机构
[1] Univ Da Nang, Univ Educ & Sci, Da Nang City 550000, Vietnam
[2] Univ Med & Pharm, Hue Univ, Hue City 530000, Vietnam
[3] Tay Nguyen Univ, Fac Nat Sci & Technol, Buon Ma Thuot City 630000, Vietnam
[4] Nong Lam Univ, Fac Sci, Ho Chi Minh City 700000, Vietnam
[5] Hue Univ, Univ Sci, Hue City 530000, Vietnam
关键词
Acetaminophen; Codeine; Paracetamol; Mn/UiO-66; UiO-66; Nanostructures; Electrochemical sensor; Pharmaceutics; METAL-ORGANIC FRAMEWORK; ELECTROCHEMICAL SENSOR; DOPED UIO-66; PARACETAMOL; NANOPARTICLES; NANOCOMPOSITE; OXIDATION; CATALYSTS; MANGANESE; TRAMADOL;
D O I
10.1007/s11051-023-05839-7
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present paper, Mn/UiO-66 material was synthesized by hydrothermal process. The obtained material was characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX) with mapping and nitrogen adsorption/desorption techniques. The doped manganese was shown to highly disperse and might be grafted into the lattice of UiO-66. A simple, fast, and inexpensive differential pulse voltammetric (DPV) method were developed using Mn/UiO-66 as an electrode modifier for the simultaneous determination of acetaminophen (ACE) and codeine (CDE) in pharmaceutical formulations. The experimental parameters, which might affect the peak currents of ACE and CDE, such as the pH of the solution, accumulation time, and scan rate, were optimized. Under optimal conditions, this technique provided low limits of detection for the quantification of ACE and CDE, of 0.45 and 0.31 & mu;M, respectively. The proposed DPV method was successfully applied to simultaneously determine ACE and CDE in samples of three pharmaceutical formulation with acceptable recoveries. Clearly, the proposed method might be an alternative option for the simultaneous determination of ACE and CDE.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Facile simultaneous electrochemical determination of codeine and acetaminophen in pharmaceutical samples and biological fluids by graphene CoFe2O4 nancomposite modified carbon paste electrode
    Afkhami, Abbas
    Khoshsafar, Hosein
    Bagheri, Hasan
    Madrakian, Tayyebeh
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 : 909 - 918
  • [42] Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid by Differential Pulse Voltammetry using Tiron Modified Glassy Carbon Electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, Taghi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (01): : 116 - 130
  • [43] Highly sensitive CuZnO-Fe3O4/rGO modified glassy carbon electrode for the electrochemical determination of acetaminophen, tyrosine and codeine in human blood plasma and urine
    Mohammadi, Negar
    Bahmaei, Manochehr
    Sharif, Amirabdolah Mehrdad
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 902
  • [44] The Determination of Riboflavin (Vitamin B2) Using Manganese Dioxide Modified Glassy Carbon Electrode by Differential Pulse Voltammetry
    Huang, De-Qian
    Wu, Hai
    Song, Chongfu
    Zhu, Qiangqiang
    Zhang, Hong
    Sheng, Liang-Quan
    Xu, Hua-Jie
    Liu, Zhao-Di
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (09): : 8303 - 8312
  • [45] Determination of analgesics in pharmaceutical formulations and urine samples using nano polypyrrole modified glassy carbon electrode
    B. Muralidharan
    G. Gopu
    C. Vedhi
    P. Manisankar
    Journal of Applied Electrochemistry, 2009, 39 : 1177 - 1184
  • [46] Differential pulse voltammetric determination of hexavalent chromium using nickel hexacyanoferrate modified glassy carbon electrode
    Dinbore, Wendimagegn T.
    Dabbo, Wolde C.
    Washe, Aemayehu P.
    SUSTAINABLE ENVIRONMENT, 2021, 7 (01):
  • [47] Voltammetric Determination of 3-Methylmorphine Using Glassy Carbon Electrode Modified with rGO and Bismuth Film
    Wong, Ademar
    Santos, Anderson M.
    Proenca, Camila A.
    Baldo, Thaisa A.
    Feitosa, Maria H. A.
    Moraes, Fernando C.
    Sotomayor, Maria D. P. T.
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [48] Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode
    Movlaee, Kaveh
    Norouzi, Parviz
    Beitollahi, Hadi
    Rezapour, Morteza
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3241 - 3251
  • [49] Visible Light Photoelectrochemical Sensor for Acetaminophen Determination using a Glassy Carbon Electrode Modified with BiVO4 Nanoparticles
    Araujo, Mayara da Silva
    Barretto, Tulio Rolim
    Rolim Galvao, Juliana Costa
    Teixeira Tarley, Cesar Ricardo
    Dall'Antonia, Luiz Henrrique
    de Matos, Roberto
    Medeiros, Roberta Antigo
    ELECTROANALYSIS, 2021, 33 (03) : 663 - 671
  • [50] Electrochemical determination of synephrine by using nafion/UiO-66/ graphene-modified screen-printed carbon electrode
    Zhang, Yi
    You, Zongyi
    Liu, Liangliang
    Duan, Shengwen
    Xiao, Aiping
    CURRENT RESEARCH IN FOOD SCIENCE, 2022, 5 : 1158 - 1166