Impact of building envelope parameters on occupants' thermal comfort and energy use in courtyard houses

被引:9
作者
Ghorbani Naeini, Hoorieh [1 ]
Norouziasas, Alireza [2 ]
Piraei, Farimah [3 ]
Kazemi, Maryam [4 ]
Kazemi, Mostafa [5 ]
Hamdy, Mohamed [2 ]
机构
[1] Univ Tehran, Coll Fine Arts, Fac Architecture, Tehran, Iran
[2] Norwegian Univ Sci & Technol, Dept Civil & Environm Engn, Trondheim, Norway
[3] Politecn Torino, Dept Energy Galileo Ferraris, Turin, Italy
[4] Qazvin Islamic Azad Univ, Fac Architecture & Urban Planning, Qazvin, Iran
[5] Univ Liege, Dept Urban & Environm Engn UEE, GeMMe Bldg Mat, Liege, Belgium
关键词
Predicted mean vote; courtyard houses; thermal load; wall construction; thermal comfort; DESIGN; MASS; OPTIMIZATION; PERFORMANCE; CONSUMPTION; STRATEGIES; CLASSROOMS; MODELS; SYSTEM;
D O I
10.1080/17452007.2023.2254294
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Courtyard houses constructed recently with air-conditioning systems need to increase efficiency by simultaneously reducing thermal load and improving thermal comfort in all seasonal zones around the yard. The envelope design is one of the effective parameters in reducing energy consumption and increasing thermal comfort. Therefore, this study investigated the effect of some design parameters related to the envelope of the building on Predicted Mean Vote (PMV) and thermal loads. The design parameters were Wall Construction (WLC) and Window Construction (WID) with different U-values (thermal transmittance), Window to Wall Ratio (WWR), Depth of Shading (DSH), and the Number of Shading (NSH). This research proposed a parametric study process that can simultaneously help designers evaluate the PMV values and thermal loads of numerous design options in four seasonal zones around the courtyard and generate optimized design solutions. According to the results, the PMV of best design solution (BS) compared with the worst design solution (WS) increased by 8%, 9%, 8%, and 12% in different zones. The thermal load decreased by 21%, 26%, 22%, and 21%. According to the sensitivity analysis, PMV values for most zones were negatively affected (decreased) by WID.
引用
收藏
页码:1725 / 1751
页数:27
相关论文
共 78 条
[1]  
Al-Saadi, 2006, ENVELOPE DESIGN THER
[2]   ICT adoption and diffusion in the construction industry of a developing economy: The case of the sultanate of Oman [J].
Alkalbani, Saeed ;
Rezgui, Yacine ;
Vorakulpipat, Chalee ;
Wilson, Ian E. .
ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2013, 9 (01) :62-75
[3]  
[Anonymous], 2020, 552004 ANSIASHRAE, DOI [10.1007/s11926-011-0203-9, DOI 10.1007/S11926-011-0203-9]
[4]  
[Anonymous], 2013, ANSI/ASHRAE standard 55- thermal environmental conditions for human occupancy
[5]  
[Anonymous], 2005, 07730 ISO
[6]  
ANSI/ASHRAE Standard 90.1, 2019, 901 ANSIASHRAE
[7]   A Review of Thermal Comfort in Residential Buildings: Comfort Threads and Energy Saving Potential [J].
Aqilah, Naja ;
Rijal, Hom Bahadur ;
Zaki, Sheikh Ahmad .
ENERGIES, 2022, 15 (23)
[8]   A CASE STUDY ON THE IMPACT OF BUILDING ENVELOPE ON ENERGY EFFICIENCY IN HIGH-RISE RESIDENTIAL BUILDINGS [J].
Aydin, Dincer ;
Mihlayanlar, Esma .
ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2020, 13 (01) :5-18
[9]   Optimization of the design of the primary school classrooms in terms of energy and daylight performance considering occupants' thermal and visual comfort [J].
Bakmohammadi, Parnian ;
Noorzai, Esmatullah .
ENERGY REPORTS, 2020, 6 :1590-1607
[10]   Assessing the usefulness of an mHealth strategy to support implementation of multi-faceted adaptive feeding interventions by community-based rehabilitation workers [J].
Bhattacharjya, Sutanuka ;
Lenker, James ;
Ghosh, Rabi .
ASSISTIVE TECHNOLOGY, 2023, 35 (03) :228-234