An adaptive targeting algorithm for magnetic resonance-guided high-intensity focused ultrasound controlled hyperthermia

被引:3
作者
Wong, Suzanne M. [1 ,2 ]
Luo, Phoebe [1 ]
Keunen, Benjamin [1 ]
Pichardo, Samuel [3 ]
Drake, James M. [1 ,2 ]
Waspe, Adam C. [1 ,4 ]
机构
[1] Hosp Sick Children, Posluns Ctr Image Guided Innovat & Therapeut Inte, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Inst Biomed Engn, Toronto, ON, Canada
[3] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[4] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
controlled hyperthermia; high intensity focused ultrasound; magnetic resonance thermometry; ABLATION; TISSUE;
D O I
10.1002/mp.16414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Mild hyperthermia has been demonstrated to improve the efficacy of chemotherapy, radiation, and immunotherapy in various cancer types. One localized, non-invasive method of administering mild hyperthermia is magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU). However, challenges for ultrasound such as beam deflection, refraction and coupling issues may result in a misalignment of the HIFU focus and the tumor during hyperthermia. Currently, the best option is to stop the treatment, wait for the tissue to cool, and redo the treatment planning before restarting the hyperthermia. This current workflow is both time-consuming and unreliable. Purpose: An adaptive targeting algorithm was developed for MRgHIFU controlled hyperthermia treatments for cancer therapeutics. This algorithm executes in real time while hyperthermia is being administered to ensure that the focus is within our target region. If a mistarget is detected, the HIFU system will electronically steer the focus of the HIFU beam to the correct target. The goal of this study was to quantify the accuracy and precision of the adaptive targeting algorithm's ability to correct a purposely misplanned hyperthermia treatment in real-time using a clinical MRgHIFU system. Methods: A gelatin phantom with acoustic properties matched to the average speed of sound in human tissue was used to test the adaptive targeting algorithm's accuracy and precision. The target was purposely offset 10 mm away from the focus at the origin, in four orthogonal directions, allowing the algorithm to correct for this mistarget. In each direction, 10 data sets were collected for a total sample size of 40. Hyperthermia was administered with a target temperature set at 42 degrees C. The adaptive targeting algorithm was run during the hyperthermia treatment and 20 thermometry images were collected after the beam steering occurred. The location of the focus was quantified by calculating the center of heating on the MR thermometry data. Results: The average calculated trajectory passed to the HIFU system was 9.7 mm +/- 0.4 mm where the target trajectory was 10 mm. The accuracy of the adaptive targeting algorithm after the beam steering correction was 0.9 mm and the precision was 1.6 mm. Conclusion: The adaptive targeting algorithm was implemented successfully and was able to correct the 10 mm mistargets with high accuracy and precision in gelatin phantoms. The results demonstrate the capability to correct the MRgHIFU focus location during controlled hyperthermia.
引用
收藏
页码:3347 / 3358
页数:12
相关论文
共 29 条
[1]   Real-Time Method for Motion-Compensated MR Thermometry and MRgHIFU Treatment in Abdominal Organs [J].
Celicanin, Zarko ;
Auboiroux, Vincent ;
Bieri, Oliver ;
Petrusca, Lorena ;
Santini, Francesco ;
Viallon, Magalie ;
Scheffler, Klaus ;
Salomir, Rares .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) :1087-1095
[2]   The performance of a reduced-order adaptive controller when used in multi-antenna hyperthermia treatments with nonlinear temperature-dependent perfusion [J].
Cheng, Kung-Shan ;
Yuan, Yu ;
Li, Zhen ;
Stauffer, Paul R. ;
Maccarini, Paolo ;
Joines, William T. ;
Dewhirst, Mark W. ;
Das, Shiva K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :1979-1995
[3]   Hyperthermia and radiotherapy with or without chemotherapy in locally advanced cervical cancer: a systematic review with conventional and network meta-analyses [J].
Datta, Niloy R. ;
Rogers, Susanne ;
Klingbiel, Dirk ;
Gomez, Silvia ;
Puric, Emsad ;
Bodis, Stephan .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2016, 32 (07) :809-821
[4]   Hyperthermia and Radiation Therapy in Locoregional Recurrent Breast Cancers: A Systematic Review and Meta-analysis [J].
Datta, Niloy R. ;
Puric, Emsad ;
Klingbiel, Dirk ;
Gomez, Silvia ;
Bodis, Stephan .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (05) :1073-1087
[5]   MR-Guided Thermotherapy of Abdominal Organs Using a Robust PCA-Based Motion Descriptor [J].
de Senneville, Baudouin Denis ;
Ries, Mario ;
Maclair, Gregory ;
Moonen, Chrit .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (11) :1987-1995
[6]  
Deenen DA, 2020, IEEE T CONTR SYST T, P2351
[7]   Hyperthermia can alter tumor physiology and improve chemo- and radio-therapy efficacy [J].
Dunne, Michael ;
Regenold, Maximilian ;
Allen, Christine .
ADVANCED DRUG DELIVERY REVIEWS, 2020, 163 :98-124
[8]   Improved Volumetric MR-HIFU Ablation by Robust Binary Feedback Control [J].
Enholm, Julia K. ;
Kohler, Max O. ;
Quesson, Bruno ;
Mougenot, Charles ;
Moonen, Chrit T. W. ;
Sokka, Shunmugavelu D. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (01) :103-113
[9]   Fever and the thermal regulation of immunity: the immune system feels the heat [J].
Evans, Sharon S. ;
Repasky, Elizabeth A. ;
Fisher, Daniel T. .
NATURE REVIEWS IMMUNOLOGY, 2015, 15 (06) :335-349
[10]   Respiration Based Steering for High Intensity Focused Ultrasound Liver Ablation [J].
Holbrook, Andrew B. ;
Ghanouni, Pejman ;
Santos, Juan M. ;
Dumoulin, Charles ;
Medan, Yoav ;
Pauly, Kim Butts .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) :797-806