Body composition in preterm infants: a systematic review on measurement methods

被引:7
|
作者
Yumani, Dana F. J. [1 ]
de Jongh, Dide [2 ,3 ]
Ket, Johannes C. F. [4 ]
Lafeber, Harrie N. [1 ]
van Weissenbruch, Mirjam M. [1 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Pediat, Amsterdam UMC, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Fac Sci, Amsterdam, Netherlands
[3] Erasmus MC, Fac Med Eth & Internal Med, Rotterdam, Netherlands
[4] Vrije Univ, Med Lib, Amsterdam, Netherlands
关键词
X-RAY ABSORPTIOMETRY; AIR-DISPLACEMENT PLETHYSMOGRAPHY; ADIPOSE-TISSUE; SKINFOLD THICKNESS; PREMATURE-INFANTS; WHOLE-BODY; VALIDATION; TERM; FAT; MASS;
D O I
10.1038/s41390-022-02262-x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background There are several methods to measure body composition in preterm infants. Yet, there is no agreement on which method should be preferred. Methods PubMed, Embase.com, Wiley/Cochrane Library, and Google Scholar were searched for studies that reported on the predictive value or validity of body composition measurements in preterms, up to 6 months corrected age. Results Nineteen out of 1884 identified studies were included. Predictive equations based on weight and length indices, body area circumferences, skinfold thickness, bioelectrical impedance, and ultrasound did not show agreement with body composition measured with air displacement plethysmography (ADP), dual-energy x-ray absorptiometry (DXA), magnetic resonance imaging (MRI), or isotope dilution. ADP agreed well with fat mass density measured by isotope dilution (bias -0.002 g/ml, limits of agreement +/- 0.012 g/ml, n = 14). Fat mass percentage measured with ADP did not agree well with fat mass percentage measured by isotope dilution (limits of agreement up to +/- 5.8%) and the bias between measurements was up to 2.2%. DXA, MRI, and isotope dilution were not compared to another reference method in preterms. Conclusions DXA, ADP, and isotope dilution methods are considered trustworthy validated techniques. Nevertheless, this review showed that these methods may not yield comparable results. Impact Based on validation studies that were conducted in a limited number of study subjects, weight and length indices, body area circumferences, skinfold thickness, bioelectrical impedance, and ultrasound seem to be a poor representation of body composition in preterm infants. DXA, ADP, and isotope dilution methods are considered trustworthy and validated techniques. Nevertheless, these methods may not yield comparable results.
引用
收藏
页码:1120 / 1140
页数:21
相关论文
共 50 条
  • [11] Human Milk Feeding and Preterm Infants' Growth and Body Composition: A Literature Review
    Cerasani, Jacopo
    Ceroni, Federica
    De Cosmi, Valentina
    Mazzocchi, Alessandra
    Morniroli, Daniela
    Roggero, Paola
    Mosca, Fabio
    Agostoni, Carlo
    Gianni, Maria Lorella
    NUTRIENTS, 2020, 12 (04)
  • [12] Clinical Application of Body Composition Methods in Premature Infants
    Nagel, Emily
    Hickey, Marie
    Teigen, Levi
    Kuchnia, Adam
    Curran, Kent
    Soumekh, Lisa
    Earthman, Carrie
    Demerath, Ellen
    Ramel, Sara
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2020, 44 (05) : 785 - 795
  • [13] A comparison of body composition measurement techniques
    Hillier, S. E.
    Beck, L.
    Petropoulou, A.
    Clegg, M. E.
    JOURNAL OF HUMAN NUTRITION AND DIETETICS, 2014, 27 (06) : 626 - 631
  • [14] Body composition measurement for the preterm neonate: using a clinical utility framework to translate research tools into clinical care
    Bell, Katherine A.
    Ramel, Sara E.
    Robinson, Daniel T.
    Wagner, Carol L.
    Scottoline, Brian
    Belfort, Mandy B.
    JOURNAL OF PERINATOLOGY, 2022, 42 (11) : 1550 - 1555
  • [15] Preterm human milk composition: a systematic literature review
    Boyce, Catherine
    Watson, Mistral
    Lazidis, Grace
    Reeve, Sarah
    Dods, Kenneth
    Simmer, Karen
    McLeod, Gemma
    BRITISH JOURNAL OF NUTRITION, 2016, 116 (06) : 1033 - 1045
  • [16] New body composition reference charts for preterm infants
    Demerath, Ellen W.
    Johnson, William
    Davern, Bridget A.
    Anderson, Christina G.
    Shenberger, Jeffrey S.
    Misra, Sonya
    Ramel, Sara E.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2017, 105 (01) : 70 - 77
  • [17] Body Composition of Infants Born with Intrauterine Growth Restriction: A Systematic Review and Meta-Analysis
    Manapurath, Rukman
    Gadapani, Barsha
    Pereira-da-Silva, Luis
    NUTRIENTS, 2022, 14 (05)
  • [18] Body composition models based on anthropometry: systematic literature review
    Eraso-Checa, Francisco
    Rosero, Ricardo
    Gonzalez, Carlos
    Cortes, David
    Hernandez, Eder
    Polanco, Juan
    Diaz-Tribaldos, Carolina
    NUTRICION HOSPITALARIA, 2023, 40 (05) : 1068 - 1079
  • [19] Validity of multi-frequency bioelectric impedance methods to measure body composition in obese patients: a systematic review
    Becroft, Louise
    Ooi, Geraldine
    Forsyth, Adrienne
    King, Susannah
    Tierney, Audrey
    INTERNATIONAL JOURNAL OF OBESITY, 2019, 43 (08) : 1497 - 1507
  • [20] Measuring body composition in the preterm infant: Evidence base and practicalities
    Andrews, Edward T.
    Beattie, R. Mark
    Johnson, Mark J.
    CLINICAL NUTRITION, 2019, 38 (06) : 2521 - 2530