共 50 条
Body composition in preterm infants: a systematic review on measurement methods
被引:7
|作者:
Yumani, Dana F. J.
[1
]
de Jongh, Dide
[2
,3
]
Ket, Johannes C. F.
[4
]
Lafeber, Harrie N.
[1
]
van Weissenbruch, Mirjam M.
[1
]
机构:
[1] Vrije Univ Amsterdam Med Ctr, Dept Pediat, Amsterdam UMC, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Fac Sci, Amsterdam, Netherlands
[3] Erasmus MC, Fac Med Eth & Internal Med, Rotterdam, Netherlands
[4] Vrije Univ, Med Lib, Amsterdam, Netherlands
关键词:
X-RAY ABSORPTIOMETRY;
AIR-DISPLACEMENT PLETHYSMOGRAPHY;
ADIPOSE-TISSUE;
SKINFOLD THICKNESS;
PREMATURE-INFANTS;
WHOLE-BODY;
VALIDATION;
TERM;
FAT;
MASS;
D O I:
10.1038/s41390-022-02262-x
中图分类号:
R72 [儿科学];
学科分类号:
100202 ;
摘要:
Background There are several methods to measure body composition in preterm infants. Yet, there is no agreement on which method should be preferred. Methods PubMed, Embase.com, Wiley/Cochrane Library, and Google Scholar were searched for studies that reported on the predictive value or validity of body composition measurements in preterms, up to 6 months corrected age. Results Nineteen out of 1884 identified studies were included. Predictive equations based on weight and length indices, body area circumferences, skinfold thickness, bioelectrical impedance, and ultrasound did not show agreement with body composition measured with air displacement plethysmography (ADP), dual-energy x-ray absorptiometry (DXA), magnetic resonance imaging (MRI), or isotope dilution. ADP agreed well with fat mass density measured by isotope dilution (bias -0.002 g/ml, limits of agreement +/- 0.012 g/ml, n = 14). Fat mass percentage measured with ADP did not agree well with fat mass percentage measured by isotope dilution (limits of agreement up to +/- 5.8%) and the bias between measurements was up to 2.2%. DXA, MRI, and isotope dilution were not compared to another reference method in preterms. Conclusions DXA, ADP, and isotope dilution methods are considered trustworthy validated techniques. Nevertheless, this review showed that these methods may not yield comparable results. Impact Based on validation studies that were conducted in a limited number of study subjects, weight and length indices, body area circumferences, skinfold thickness, bioelectrical impedance, and ultrasound seem to be a poor representation of body composition in preterm infants. DXA, ADP, and isotope dilution methods are considered trustworthy and validated techniques. Nevertheless, these methods may not yield comparable results.
引用
收藏
页码:1120 / 1140
页数:21
相关论文