The effect of pre-ceramic soldering on marginal and internal fit of 4-unit zirconia frameworks and monolithic zirconia fixed dental prostheses

被引:0
作者
Irem, Diler Ozkan
Alpkilic, Dilara Seyma [1 ]
Deger, Sabire Isler [1 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, TR-34452 Istanbul, Turkiye
关键词
Zirconia; Pre-ceramic soldering; Marginal fit; Internal fit; LITHIUM DISILICATE CROWNS; PARTIAL DENTURES; RESTORATIONS; ADAPTATION; METAL; TOOTH; TOMOGRAPHY; COPINGS; SYSTEMS; 3D;
D O I
10.1007/s10266-023-00826-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study is to evaluate the effect of pre-ceramic soldering on the marginal and internal fit of 4-unit zirconia fixed dental prostheses (FPDs) that have two abutments and two pontics. 4-unit zirconia frameworks (Zirkonzahn ICE Translucent) (Z Group) and monolithic zirconia (Zirkonzahn Prettau) (M Group) FPDs were manufactured. Groups were divided into two groups (n = 10) control (ZC and MC) and soldering (ZS and MS). Samples of ZS and MS groups were cut into two pieces under cooling water and soldered with a bonding material (DCM Zircon HotBond). The marginal and internal fit of the restorations were measured from 36 points of each sample and cement space volume was calculated using reverse engineering software (Geomagic Design X). The mean and standard deviations were submitted to Generalized Linear Mixed Model (GLMM) analysis (& alpha; = 0.05). Statistical differences between groups before and after pre-ceramic soldering on point measurements were found. In total cement spacing measurements, a significant difference was found amongst all groups (P < 0.05). However, in premolars, a statistically significant difference was found between ZC and ZS groups and MC and MS groups (P < 0.05). All discrepancies after pre-ceramic soldering were found to be lower than before.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 50 条
  • [21] Accuracy, fit, and marginal quality of advanced additively manufactured and milled zirconia 3-unit fixed dental prostheses
    Wang, Yujie
    Zhou, Yi
    Zhu, Han
    Jiang, Jimin
    He, Fuming
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (01) : 208e1 - 208e10
  • [22] Clinical fit of four-unit zirconia posterior fixed dental prostheses
    Reich, Sven
    Kappe, Karsten
    Teschner, Hubertus
    Schmitt, Johannes
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2008, 116 (06) : 579 - 584
  • [23] Evaluation of Marginal and Internal Fit of Presintered Co-Cr and Zirconia Three-Unit Fixed Dental Prosthesis Compared to Cast Co-Cr
    Daou, Elie E.
    Baba, Nadim Z.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09): : 792 - 799
  • [24] Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems
    Lehmann, Karl Martin
    Weyhrauch, Michael
    Bjelopavlovic, Monika
    Scheller, Herbert
    Staedt, Henning
    Ottl, Peter
    Kaemmerer, Peer W.
    Wentaschek, Stefan
    [J]. MATERIALS, 2021, 14 (10)
  • [25] Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans
    Uluc, Irem Gokce
    Guncu, Mustafa Baris
    Aktas, Guliz
    Turkyilmaz, Ilser
    [J]. JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 63 - 69
  • [26] Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study
    Bandiaky, Octave Nadile
    Clouet, Roselyne
    Le Bars, Pierre
    Soueidan, Assem
    Le Guehennec, Laurent
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 846 - 853
  • [27] In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
    Choi, Jae-Won
    Kim, So-Yeun
    Bae, Ji-Hyeon
    Bae, Eun-Bin
    Huh, Jung-Bo
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (04) : 244 - 251
  • [28] Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression
    Su, Ting-Shu
    Sun, Jian
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (03) : 362 - 367
  • [29] Effect of mastication simulation on the phase transformation of posterior 3-unit monolithic zirconia fixed dental prostheses
    Erdinc, Gulbahar
    Bulbul, Mehmet
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (06) : 794.e1 - 794.e6
  • [30] Sintering distortion of monolithic zirconia in 4-unit fixed partial denture: Effect of layered structure and vertical milling area
    Hirano, Mizuho
    Nomoto, Syuntaro
    Sato, Toru
    Yotsuya, Mamoru
    Hisanaga, Ryuichi
    Sekine, Hideshi
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 128