Experimental investigation on the seismic performance of prefabricated fiber-reinforced concrete beam-column joints using grouted sleeve connections

被引:6
作者
Sun, Chuanzhi [1 ]
Zhuang, Mei-Ling [2 ,6 ]
Wang, Zhenbo [3 ]
Chen, Baodong [3 ]
Gao, Li [1 ]
Qiao, Yan [1 ]
Zhu, Hanbo [1 ]
Zhang, Weihua [4 ]
Yang, Jun [5 ]
Yu, Changrong [2 ]
机构
[1] Suqian Coll, Sch Civil Engn & Architecture, Suqian, Peoples R China
[2] Nantong Univ, Sch Transportat & Civil Engn, Nantong, Peoples R China
[3] Nanjing Tech Univ, Coll Civil Engn, Nanjing, Peoples R China
[4] Yigongju Bridge & Tunnel Engn Co Ltd, Changsha, Peoples R China
[5] Suzhou Univ Sci & Technol, Sch Civil Engn, Suzhou, Peoples R China
[6] Nantong Univ, Sch Transportat & Civil Engn, Nantong 226019, Peoples R China
关键词
beam-column joint; fiber-reinforced concrete; prefabricated reinforced concrete structure; seismic performance; sleeve connection; wet joint; FLEXURAL MEMBERS; BEHAVIOR; ECC; DUCTILITY; FRAMES;
D O I
10.1002/suco.202200823
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To improve the seismic performance of prefabricated reinforced conventional concrete (PRC) beam-column joints, fiber-reinforced concrete (FRC) was used instead of concrete in the core zone of the joint in this article. The optimum volume contents of polyvinyl alcohol (PVA) fibers and steel fibers were first determined to be 0.3% and 1%, respectively, through the material properties tests. Then, four PRC beam-column joint specimens using grouted sleeve connections and one cast-in-place reinforced concrete beam-column joint specimen were designed considering the factors of PVA fibers, steel fibers, with or without stirrups. The test phenomena and failure mode of the five specimens under low-cycle cyclic loads were obtained. Finally, the effects of PVA fibers, steel fibers, with or without stirrups on the seismic performance of specimens were analyzed and discussed. The test phenomena indicated that the failure mode of specimens was anchorage damage of steel bars. The prefabricated FRC specimens showed relatively little damage in the core zone of the joint. FRC had a significant improvement on the seismic performance of prefabricated beam-column joints. The use of FRC in the core zone of the joint can reduce or even eliminate the use of stirrups.
引用
收藏
页码:4702 / 4718
页数:17
相关论文
共 50 条
  • [1] Numerical Simulation Study on the Seismic Performance of Prefabricated Fiber-Reinforced Concrete Beam-Column Joints With Grouted Sleeve Connections
    Zhuang, Mei-Ling
    Cheng, Jinsheng
    Fei, Dongsong
    Sun, Chuanzhi
    Wang, Zhenbo
    Chen, Baodong
    Qiao, Yan
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2024, 18 (01)
  • [2] Seismic performance of fiber-reinforced concrete interior beam-column joints
    Liang, Xing-wen
    Wang, Ying-jun
    Tao, Yi
    Deng, Ming-ke
    ENGINEERING STRUCTURES, 2016, 126 : 432 - 445
  • [3] Mechanical performance of prefabricated concrete beam-column joints with double-grouted sleeve connectors: A numerical and theoretical study
    Lu, Zhiwei
    Wu, Bin
    Sakata, Hiroyasu
    Huang, Jun
    Zhang, Mingzhong
    STRUCTURES, 2023, 56
  • [4] Experimental study on the seismic performance of steel-concrete beam-column connections for prefabricated concrete frames
    Zhang, Jianxin
    Li, Chenchen
    Rong, Xian
    Zhang, Xiaowei
    Li, Yanyan
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [5] Experimental Study of the Seismic Performance of Concrete Beam-Column Frame Joints with DfD Connections
    Ding, Tao
    Xiao, Jianzhuang
    Chen, Enci
    Khan, Asad-ur-Rehman
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (04)
  • [6] Study of seismic performance of reinforced concrete frame beam-column joints connected with grouted sleeves
    Liu H.
    Yan Q.
    Du X.
    Du, Xiuli (duxiuli@bjut.edu.cn), 1600, Science Press (38): : 54 - 61
  • [7] Seismic performance of prefabricated composite frame beam-column joints with grouted end-plate bolted connections
    Zhang X.
    Ma X.
    Zhang S.
    Li Q.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 101 - 111
  • [8] Investigation on the seismic rehabilitation of reinforced concrete beam-column joints
    Zhao, G. D.
    Cao, S. Y.
    Zhang, Y. F.
    ISISS '2007: PROCEEDINGS OF THE INNOVATION AND SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2008, : 954 - 959
  • [9] Ductility Enhancement in Beam-Column Connections Using Hybrid Fiber-Reinforced Concrete
    Kheni, Dhaval
    Scott, Richard H.
    Deb, S. K.
    Dutta, Anjan
    ACI STRUCTURAL JOURNAL, 2015, 112 (02) : 167 - 178
  • [10] Seismic Performance of Lightly Reinforced Concrete Exterior Beam-Column Joints
    Meas, Kimreth
    Li, Bing
    Imran, Iswandi
    ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (10) : 1765 - 1780