Evaluation of the transmission tower and frequency-dependent soil parameters influence on the grounding potential rise waveforms

被引:0
|
作者
Schroeder, Marco Aurelio O. [1 ]
Moura, Rodolfo A. R. [1 ]
Assis, Fernando A. [1 ]
Paulino, Jose O. S. [2 ]
机构
[1] Fed Univ Sao Joao Del Rei UFSJ, Elect Engn Dept, Sao Joao Del Rei, MG, Brazil
[2] Fed Univ Minas Gerais UFMG, Elect Engn Dept, Belo Horizonte, MG, Brazil
关键词
Grounding potential rise; Lightning transient grounding behavior; Transmission tower; Frequency-dependence of soil parameters; Human protection; LIGHTNING RESPONSE; IMPULSE EFFICIENCY; CURRENTS; MODEL; ELECTRODES; IMPEDANCE; LINES;
D O I
10.1016/j.epsr.2023.109495
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the influence of the transmission tower and the frequency-dependent soil parameters on the grounding potential rise (GPR) waveform is evaluated. This evaluation is performed using a physically consistent electromagnetic model that determines the transient behavior of the grounding system submitted by lightning, together with the Alternative Transients Program for the representation of aerial elements (tower, phase cables and shield wires). This model was developed in the frequency domain and, in this way, allows the inclusion of frequency-dependence of soil electrical parameters. In this sense, three formulations of the dependence in question are considered, widely disseminated in the literature, and determined through systematic measurement processes. The results illustrate that the concomitant inclusion of the tower and the frequency-dependence substantially modifies the GPR waveforms, when compared with those in which isolated grounding is considered, especially for soils with high resistivity values and for first return strokes. This is of most importance when evaluating personal safety criteria in the transmission tower vicinity. In these situations, the GPR waveforms should be determined by considering the presence of the tower and not only with the isolated grounding, since the transient step and touch voltages are directly associated with GPR.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Grounding system impedance influence on the surge arrester frequency-dependent model parameters using PSO-GWO algorithm
    Khodsuz, Masume
    Mashayekhi, Valiollah
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2023, 42 (06) : 1456 - 1476
  • [32] A Simplified Method for the Evaluation of Lightning-Induced Overvoltage Peaks with Frequency-Dependent Soil Parameters
    Moura, Rodolfo A. R.
    Mestriner, Daniele
    Procopio, Renato
    Schroeder, Marco A. O.
    Assis, Fernando A.
    Nicora, Martino
    Delfino, Federico
    2022 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2022 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2022,
  • [33] Evaluation of Lightning-Induced Voltages over Lossy Ground with Frequency-dependent Soil Parameters
    Silveira, Fernando H.
    De Conti, Alberto
    Visacro, Silverio
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 950 - 954
  • [34] An Analysis of Frequency-Dependent Soil Models: Influence on the Transient Responses
    Pascoalato, Taina F. G.
    de Araujo, Anderson R. J.
    Colqui, Jaimis S. L.
    Kurokawa, Sergio
    Pissolato Filho, Jose
    2021 14TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2021, : 1 - 8
  • [35] Distance protection for HVDC transmission line considering frequency-dependent parameters
    Zhang, J. (zhangjk@nw.sgcc.com.cn), 1600, Automation of Electric Power Systems Press (36):
  • [36] Estimation of the Frequency-Dependent Parameters of Transmission Lines by Using Synchronized Measurements
    Gerez, Cassio
    Angelos, Eduardo Werley S.
    Albuquerque, Felipe P.
    Marques da Costa, Eduardo C.
    Sguarezi Filho, Alfeu J.
    Bartocci Liboni, Luisa H.
    IEEE ACCESS, 2022, 10 : 17526 - 17541
  • [37] Distance Protection for HVDC Transmission Lines Considering Frequency-Dependent Parameters
    Suonan, Jiale
    Zhang, Jiankang
    Jiao, Zaibin
    Yang, Liming
    Song, Guobing
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 723 - 732
  • [38] Influence of frequency-dependent characteristics of grounding and line models on transient overvoltages in overhead lines
    Alipio, Rafael
    De Miranda, Audine
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (02): : 1 - 4
  • [39] Frequency Characteristics of Fault Transients for HVDC Transmission Line with Frequency-dependent Distributed Parameters
    Wang Yafei
    Yu Yang
    Liu Shuli
    Hu Yuanchao
    Gao Tonghu
    Zhang Pengfeng
    Si Shukai
    Yu Hong
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,
  • [40] Impact of Frequency-Dependent Soil Models on Grounding System Performance for Direct and Indirect Lightning Strikes
    Nazari, Moein
    Moini, Rouzbeh
    Fortin, Simon
    Dawalibi, Farid P.
    Rachidi, Farhad
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (01) : 134 - 144