Machine learning-based signal quality assessment for cardiac volume monitoring in electrical impedance tomography

被引:3
作者
Hyun, Chang Min [1 ]
Jang, Tae Jun [1 ]
Nam, Jeongchan [2 ]
Kwon, Hyeuknam [3 ]
Jeon, Kiwan [4 ]
Lee, Kyounghun [5 ]
机构
[1] Yonsei Univ, Sch Math & Comp Computat Sci & Engn, Seoul, South Korea
[2] BiLab, Seongnam, South Korea
[3] Yonsei Univ, Div Software, Wonju, South Korea
[4] Natl Inst Math Sci, Daejeon, South Korea
[5] Kyung Hee Univ, Seoul, South Korea
来源
MACHINE LEARNING-SCIENCE AND TECHNOLOGY | 2023年 / 4卷 / 01期
关键词
cardiac volume monitoring; electrical impedance tomography; machine learning; signal quality assessment; CONDUCTIVITY CHANGES; EIT; VENTILATION; IMAGES;
D O I
10.1088/2632-2153/acc637
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Owing to recent advances in thoracic electrical impedance tomography (EIT), a patient's hemodynamic function can be noninvasively and continuously estimated in real-time by surveilling a cardiac volume signal (CVS) associated with stroke volume and cardiac output. In clinical applications, however, a CVS is often of low quality, mainly because of the patient's deliberate movements or inevitable motions during clinical interventions. This study aims to develop a signal quality indexing method that assesses the influence of motion artifacts on transient CVSs. The assessment is performed on each cardiac cycle to take advantage of the periodicity and regularity in cardiac volume changes. Time intervals are identified using the synchronized electrocardiography system. We apply divergent machine-learning methods, which can be sorted into discriminative-model and manifold-learning approaches. The use of machine-learning could be suitable for our real-time monitoring application that requires fast inference and automation as well as high accuracy. In the clinical environment, the proposed method can be utilized to provide immediate warnings so that clinicians can minimize confusion regarding patients' conditions, reduce clinical resource utilization, and improve the confidence level of the monitoring system. Numerous experiments using actual EIT data validate the capability of CVSs degraded by motion artifacts to be accurately and automatically assessed in real-time by machine learning. The best model achieved an accuracy of 0.95, positive and negative predictive values of 0.96 and 0.86, sensitivity of 0.98, specificity of 0.77, and AUC of 0.96.
引用
收藏
页数:18
相关论文
共 61 条
  • [1] Impedance imaging of lung ventilation: Do we need to account for chest expansion?
    Adler, A
    Guardo, R
    Berthiaume, Y
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (04) : 414 - 420
  • [2] Electrical Impedance Tomography: Tissue Properties to Image Measures
    Adler, Andy
    Boyle, Alistair
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (11) : 2494 - 2504
  • [3] Understanding diagnostic tests 3: receiver operating characteristic curves
    Akobeng, Anthony K.
    [J]. ACTA PAEDIATRICA, 2007, 96 (05) : 644 - 647
  • [4] A Fast Machine Learning Model for ECG-Based Heartbeat Classification and Arrhythmia Detection
    Alfaras, Miquel
    Soriano, Miguel C.
    Ortin, Silvia
    [J]. FRONTIERS IN PHYSICS, 2019, 7
  • [5] Askari A T., 2019, Cardiovascular Hemodynamics, V2nd edn
  • [6] Biosignals learning and synthesis using deep neural networks
    Belo, David
    Rodrigues, Joao
    Vaz, Joao R.
    Pezarat-Correia, Pedro
    Gamboa, Hugo
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [7] Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse
    Borges, Joao Batista
    Suarez-Sipmann, Fernando
    Bohm, Stephan H.
    Tusman, Gerardo
    Melo, Alexandre
    Maripuu, Enn
    Sandstrom, Mattias
    Park, Marcelo
    Costa, Eduardo L. V.
    Hedenstierna, Goran
    Amato, Marcelo
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 225 - 236
  • [8] Boyle Alistair, 2010, Journal of Physics: Conference Series, V224, DOI 10.1088/1742-6596/224/1/012051
  • [9] BLOOD-FLOW IMAGING USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BROWN, BH
    LEATHARD, A
    SINTON, A
    MCARDLE, FJ
    SMITH, RWM
    BARBER, DC
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 175 - 179
  • [10] A systematic study of the class imbalance problem in convolutional neural networks
    Buda, Mateusz
    Maki, Atsuto
    Mazurowski, Maciej A.
    [J]. NEURAL NETWORKS, 2018, 106 : 249 - 259