Experimental investigation of lightweight aggregate concrete-filled cold-formed built-up box section (CFBBS) stub columns under axial compression

被引:8
作者
Bin Teoh, Keat [1 ]
Chua, Yie Sue [1 ,2 ]
Pang, Sze Dai [3 ]
Kong, Sih Ying [1 ]
机构
[1] Monash Univ Malaysia, Sch Engn, Jalan Lagoon Selatan, Bandar Sunway 47500, Selangor, Malaysia
[2] Monash Univ Malaysia, Sch Engn, Monash Construct Circular Node Monash ConCerN, Jalan Lagoon Selatan, Bandar Sunway 47500, Selangor, Malaysia
[3] Natl Univ Singapore, Dept Civil & Environm Engn, 1 Engn Dr 2, Singapore 117576, Singapore
关键词
Cold-formed steel; Built-up box section columns; Concrete-filled steel tubes; Lightweight aggregate concrete; Thin-walled; HIGH-STRENGTH STEEL; EXPERIMENTAL BEHAVIOR; TUBE COLUMNS; DESIGN; PERFORMANCE; CAPACITY; TESTS;
D O I
10.1016/j.engstruct.2023.115630
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental investigation of cold-formed built-up box section (CFBBS) stub columns infilled with lightweight aggregate concrete under concentric loading. The experimental programme included a series of twenty-four lightweight aggregate concrete-filled built-up box sections comprising by two nested cold-formed thin-walled C-sections using breakstem rivets at flange and eight reference hollow sections for comparison purposes. These built-up sections of four different cross-section sizes were infilled with three different lightweight concrete compression strengths, i.e., 20, 30 and 40 MPa. The failure modes, ultimate compressive load and load-end shortening relationship of the test specimens were compared and discussed. A set of performance indices was calculated from the test results to evaluate the structural performance from several aspects. In addition, the confinement effect of the specimens was investigated extensively based on the strain development. Finally, the experimental results are used to evaluate the applicability of the design equations specified in the existing codified provisions, including Eurocode (EC4), Australia/New Zealand Standard (AS/NZS 2327) and America Specification (AISC 360-16). It was found that EC4 with consideration of effective area of the outer CFBBS in the design provided the most accurate and less scattered predictions. Predictions from AS/NZS 2327 were generally found to be slightly unsafe while those from AISC 360-16 were conservative.
引用
收藏
页数:17
相关论文
共 77 条
  • [1] Behavior of Reinforced Lightweight Aggregate Concrete-filled Circular Steel Tube Columns Under Axial Loading
    Al-Eliwi, Baraa J. M.
    Ekmekyapar, Talha
    Al-Samaraie, Mohanad I. A.
    Dogru, M. Hanifi
    [J]. STRUCTURES, 2018, 16 : 101 - 111
  • [2] Performance of lightweight aggregate and self-compacted concrete-filled steel tube columns
    AL-Eliwi, Baraa J. M.
    Ekmekyapar, Talha
    Faraj, Radhwan H.
    Gogus, M. Tolga
    AL-Shaar, Ahmed A. M.
    [J]. STEEL AND COMPOSITE STRUCTURES, 2017, 25 (03) : 299 - 314
  • [3] Altan T., 2012, SHEET METAL FORMING
  • [4] Experimental study on structural performance of UHPC and UHPFRC columns confined with steel tube
    An Le Hoang
    Fehling, Ekkehard
    Lai, Binglin
    Duc-Kien Thai
    Nguyen Van Chau
    [J]. ENGINEERING STRUCTURES, 2019, 187 : 457 - 477
  • [5] Influence of concrete strength and length/diameter on the axial capacity of CFT columns
    Andrade de Oliveira, Walter Luiz
    De Nardin, Silvana
    de Cresce El Debs, Ana Lucia H.
    El Debs, Mounir Khalil
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (12) : 2103 - 2110
  • [6] [Anonymous], 2021, ASTME8/E8M-21
  • [7] [Anonymous], 2017, ASNZS2327
  • [8] [Anonymous], 2014, 213 AC
  • [9] [Anonymous], 2021, ASTMC39C39M21
  • [10] [Anonymous], 2008, Recommendations for design and construction of concrete filled steel tubular structures