Precision estimates of relative and absolute cerebral blood flow in Alzheimer's disease and cognitively normal individuals

被引:6
作者
Heeman, Fiona [1 ]
Visser, Denise [1 ]
Yaqub, Maqsood [1 ]
Verfaillie, Sander [1 ,2 ]
Timmers, Tessa [1 ]
Pijnenburg, Yolande A. L. [3 ]
van der Flier, Wiesje M. [3 ,4 ]
van Berckel, Bart N. M. [1 ]
Boellaard, Ronald [1 ]
Lammertsma, Adriaan A. [1 ]
Golla, Sandeep S., V [1 ]
机构
[1] Vrije Univ Amsterdam, Amsterdam UMC, Amsterdam Neurosci, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[2] Univ Amsterdam, Amsterdam UMC, Amsterdam Publ Hlth, Dept Med Psychol, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Amsterdam UMC, Alzheimer Ctr Amsterdam, Dept Neurol,Amsterdam Neurosci, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, Amsterdam UMC, Dept Epidemiol & Biostat, Amsterdam, Netherlands
关键词
Cerebral blood flow; PET; precision; Alzheimer's disease; healthy controls; TF PET/CT SCANNER; PERFORMANCE; IMPAIRMENT; PERFUSION; CBF;
D O I
10.1177/0271678X221135270
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Alzheimer's disease is characterized by regional reductions in cerebral blood flow (CBF). Although the gold standard for measuring CBF is [O-15]H2O PET, proxies of relative CBF, derived from the early distribution phase of amyloid and tau tracers, have gained attention. The present study assessed precision of [O-15]H2O derived relative and absolute CBF, and compared precision of these measures with that of (relative) CBF proxies. Dynamic [O-15]H2O, [F-18]florbetapir and [F-18]flortaucipir PET test-retest (TrT) datasets with eleven, nine and fourteen subjects, respectively, were included. Analyses were performed using an arterial input model and/or a simplified reference tissue model, depending on the data available. Relative CBF values (i.e. K-1/K-1 ' and/or R-1) were obtained using cerebellar cortex as reference tissue and TrT repeatability (i.e. precision) was calculated and compared between tracers, parameters and clinical groups. Relative CBF had significantly better TrT repeatability than absolute CBF derived from [O-15]H2O (r = -0.53), while best TrT repeatability was observed for [F-18]florbetapir and [F-18]flortaucipir R-1 (r = -0.23, r = -0.33). Furthermore, only R-1 showed, better TrT repeatability for cognitively normal individuals. High precision of CBF proxies could be due to a compensatory effect of the extraction fraction, although changes in extraction fraction could also bias these proxies, but not the gold standard.
引用
收藏
页码:369 / 378
页数:10
相关论文
共 44 条
[1]  
[Anonymous], 2014, Comprehensive Psychology, DOI [10.2466/11.IT.3.1, DOI 10.2466/11.IT.3.1]
[2]   Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[3]   Longitudinal evaluation of surrogates of regional cerebral blood flow computed from dynamic amyloid PET imaging [J].
Bilgel, Murat ;
Beason-Held, Lori ;
An, Yang ;
Zhou, Yun ;
Wong, Dean F. ;
Resnick, Susan M. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2020, 40 (02) :288-297
[4]   Cerebral perfusion in the predementia stages of Alzheimer's disease [J].
Binnewijzend, Maja A. A. ;
Benedictus, Marije R. ;
Kuijer, Joost P. A. ;
van der Flier, Wiesje M. ;
Teunissen, Charlotte E. ;
Prins, Niels D. ;
Wattjes, Mike P. ;
van Berckel, Bart N. M. ;
Scheltens, Philip ;
Barkhof, Frederik .
EUROPEAN RADIOLOGY, 2016, 26 (02) :506-514
[5]   Cerebral Blood Flow Measured with 3D Pseudocontinuous Arterial Spin-labeling MR Imaging in Alzheimer Disease and Mild Cognitive Impairment: A Marker for Disease Severity [J].
Binnewijzend, Maja A. A. ;
Kuijer, Joost P. A. ;
Benedictus, Marije R. ;
van der Flier, Wiesje M. ;
Wink, Alle Meije ;
Wattjes, Mike P. ;
van Berckel, Bart N. M. ;
Scheltens, Philip ;
Barkhof, Frederik .
RADIOLOGY, 2013, 267 (01) :221-230
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET [J].
Boellaard, R ;
van Lingen, A ;
van Balen, SCM ;
Hoving, BG ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) :81-89
[8]   Day-to-Day Test-Retest Variability of CBF, CMRO2, and OEF Measurements Using Dynamic 15O PET Studies [J].
Bremmer, Jochem P. ;
van Berckel, Bart N. M. ;
Persoon, Suzanne ;
Kappelle, L. Jaap ;
Lammertsma, Adriaan A. ;
Kloet, Reina ;
Luurtsema, Gert ;
Rijbroek, Abraham ;
Klijn, Catharina J. M. ;
Boellaard, Ronald .
MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (04) :759-768
[10]   Validation of Noninvasive Tracer Kinetic Analysis of 18F-Florbetaben PET Using a Dual-Time-Window Acquisition Protocol [J].
Bullich, Santiago ;
Barthel, Henryk ;
Koglin, Norman ;
Becker, Georg A. ;
De Santi, Susan ;
Jovalekic, Aleksandar ;
Stephens, Andrew W. ;
Sabri, Osama .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (07) :1104-1110