An Efficient Method for Identifying the Inactive Transmission Constraints in a Network-Constrained Unit Commitment

被引:2
作者
Ma, Ziming [1 ,2 ]
Zhong, Haiwang [1 ,2 ]
Xia, Qing [1 ,2 ]
Kang, Chongqing [1 ,2 ]
Wang, Qiang [3 ]
Cao, Xin
机构
[1] Tsinghua Univ, State Key Lab Power Syst, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[3] State Grid Hebei Elect Power Co, Shijiazhuang 050000, Peoples R China
基金
中国国家自然科学基金;
关键词
Load flow; Linear programming; Electricity supply industry; Economics; Optimization; Acceleration; Inactive transmission constraints; improved relaxation inducement (IRI); network-constrained unit commitment (NCUC); relaxation-based neighborhood search (RBNS); SCUC; IDENTIFICATION;
D O I
10.17775/CSEEJPES.2020.00360
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Network-constrained unit commitment (NCUC) is one of the most widely used applications in power system and electricity market operations. According to empirical evidence, some of the transmission constraints in a NCUC are inactive. Identifying and eliminating these inactive constraints can improve the efficiency. In this paper, an efficient method is first proposed for identifying the inactive transmission constraints. The physical and economic insights of NCUC are carefully considered and utilized. Both the generating costs and power transfer distribution factor (PTDF) are considered. Not only redundant constraints but also non-binding constraints can be identified via the proposed method. An acceleration method that combines relaxation-based neighborhood search and improved relaxation inducement is proposed for further reducing the computation time. The case study shows that the proposed method can significantly reduce the number of transmission constraints and substantially improve the efficiency of NCUC without impacting the optimality.
引用
收藏
页码:2366 / 2373
页数:8
相关论文
共 19 条
[1]   Acceleration of Umbrella Constraint Discovery in Generation Scheduling Problems [J].
Ardakani, Ali Jahanbani ;
Bouffard, Francois .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (04) :2100-2109
[2]   Identification of Umbrella Constraints in DC-Based Security-Constrained Optimal Power Flow [J].
Ardakani, Ali Jahanbani ;
Bouffard, Francois .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) :3924-3934
[3]   Improving Large Scale Day-Ahead Security Constrained Unit Commitment Performance [J].
Chen, Yonghong ;
Casto, Aaron ;
Wang, Fengyu ;
Wang, Qianfan ;
Wang, Xing ;
Wan, Jie .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (06) :4732-4743
[4]   Robust Unit Commitment for Large-scale Wind Generation and Run-off-river Hydropower [J].
Chen, Yue ;
Liu, Feng ;
Wei, Wei ;
Mei, Shengwei ;
Chang, Naichao .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2016, 2 (04) :66-75
[5]  
Cvijic S, 2011, IEEE POW ENER SOC GE
[6]   Robust Co-Optimization to Energy and Ancillary Service Joint Dispatch Considering Wind Power Uncertainties in Real-Time Electricity Markets [J].
Ding, Tao ;
Wu, Zhongyu ;
Lv, Jiajun ;
Bie, Zhaohong ;
Zhang, Xianjun .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2016, 7 (04) :1547-1557
[7]   Fast SCUC for large-scale power systems [J].
Fu, Yong ;
Shahidehpour, Mohammad .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (04) :2144-2151
[8]   Determining inactive constraints in stochastic security-constrained unit commitment using cumulants [J].
Ghannadi, Siavash ;
Mehrtash, Mahdi ;
Mohammadi, Mohammad ;
Raoofat, Mahdi .
JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2017, 32 (03) :2123-2135
[9]   Identification of Simultaneously Congested Transmission Lines in Power Systems Operation and Market Analysis [J].
Javadi, Milad ;
Hong, Mingguo ;
Angarita, Ruth N. ;
Hosseini, Seyed Hossein ;
Jiang, John Ning .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (03) :1772-1781
[10]   A Unit Commitment Algorithm With Relaxation-Based Neighborhood Search and Improved Relaxation Inducement [J].
Ma, Ziming ;
Zhong, Haiwang ;
Xia, Qing ;
Kang, Chongqing ;
Wang, Qiang ;
Cao, Xin .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (05) :3800-3809