Comprehensive improvements in the emergency laboratory test process based on information technology

被引:1
作者
Zhang, Liang [1 ]
Liu, Zhen Hua [2 ]
Lv, Yin Jiang [1 ]
Fu, Shui [1 ]
Luo, Zhang Mei [1 ]
Guo, Mei Li [3 ]
机构
[1] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Dept Clin Lab, Linping Campus, Hangzhou 311100, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sch Med, Dept Gen Surg, Affiliated Hosp 2, Linping Campus, Hangzhou 311100, Peoples R China
[3] Peoples Hosp Cangnan Zhejiang, Dept Clin Lab, 2288 Yucang Rd, Cangnan Cty 325800, Zhejiang, Peoples R China
关键词
Information technology; Emergency laboratory test; Process optimisation; Satisfaction; Turn-around time; TURNAROUND TIME;
D O I
10.1186/s12911-023-02387-x
中图分类号
R-058 [];
学科分类号
摘要
Objective To explore the application effects of information technology (IT) on emergency laboratory testing procedures.Methods In this study, IT-based optimisation of the emergency laboratory testing process was implemented between October and December 2021. Thus, the emergency laboratory test reports from January to September 2021 were placed into the pre-optimised group, while those from January to September 2022 were categorised into the post-optimised group. Besides, the emergency laboratory test report time, emergency laboratory test report time limit coincidence rate, error rate, and employee and patient satisfaction levels in individual months and across the whole period were described. Moreover, changes in the above indicators before and after the implementation of IT-based optimisation were explored and the application effects of IT-based optimisation were also evaluated.Results The emergency laboratory test report times after the implementation of IT-based optimisation were shorter than those before IT-based optimisation (P < 0.05). The total number of laboratory test items before and after information optimization amounted to 222,139 and 259,651, respectively. Also, IT-based optimisation led to an increase in the emergency laboratory test report time limit coincidence rate from 98.77% to 99.03% (P < 0.05), while the emergency laboratory test report error rate fell from 0.77 & pertenk; to 0.15 & pertenk; (P < 0.05). Additionally, IT-based optimisation resulted in increases in both employee satisfaction, from 80.65% to 93.55% (N = 31, P > 0.05), and patient satisfaction, from 93.06% to 98.44% (P < 0.05).Conclusion The automation and IT-based optimisation of the emergency laboratory testing process significantly reduces the emergency laboratory test report time and error rate. Additionally, IT-driven optimization enhances the alignment of emergency laboratory test report deadlines and enhances the overall quality and safety of emergency laboratory testing.
引用
收藏
页数:11
相关论文
共 22 条
  • [1] Chinese Medical Association Laboratory Medicine Branch Chinese Physician Association Emergency Physician Branch Chinese Peoples Liberation Army Emergency Medicine Professional Committee, 2020, Chin J Lab Med, V43, P1, DOI [10.3760/cma.j.issn.10098158.2020.01.001, DOI 10.3760/CMA.J.ISSN.1009]
  • [2] Indications and Interpretation of Common Laboratory Assays in the Emergency Department
    Cruz, Andrea T.
    [J]. PEDIATRIC CLINICS OF NORTH AMERICA, 2018, 65 (06) : 1191 - +
  • [3] Turnaround Time: An Efficacy Measure for Medical Laboratories
    Dawande, Pratibha P.
    Wankhade, Rashmi S.
    Akhtar, Faizan, I
    Noman, Obaid
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [4] [费阳 Fei Yang], 2017, [中华检验医学杂志, Chinese Journal of Laboratory Medicine], V40, P535
  • [5] Service Quality Improvement of Outpatient Blood Collection by Lean Management
    Fu, Shui
    Wu, Xian-Guo
    Zhang, Liang
    Wu, Li-Feng
    Luo, Zhang-Mei
    Hu, Qi-Lei
    [J]. PATIENT PREFERENCE AND ADHERENCE, 2021, 15 : 1537 - 1543
  • [6] Application of computer simulation analysis to assess the effects of relocating a hospital phlebotomy department
    Groothuis, S
    Goldschmidt, HMJ
    Drupsteen, EJ
    de Vries, JCM
    Hasman, A
    van Merode, GG
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2002, 39 : 261 - 272
  • [7] International Organization for Standardization (ISO), 2012, EN-ISO15189-medical laboratories-requirements for quality and competence, V3rd
  • [8] Joint Commission on Accreditation of Healthcare Organizations, 2017, JOINT COMM INT ACCR
  • [9] Quality benchmarking of smartphone laboratory medicine applications: comparison of laboratory medicine specialists' and non-laboratory medicine professionals' evaluation
    Jovicic, Snezana
    Siodmiak, Joanna
    Duque Alcorta, Marta
    Kittel, Maximillian
    Oosterhuis, Wytze
    Aakre, Kristin Moberg
    Jorgensen, Per
    Palicka, Vladimir
    Kutt, Marge
    Anttonen, Mikko
    Velizarova, Mileva Georgieva
    Marc, Jania
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (04) : 693 - 699
  • [10] Karitis Konstantinos, 2021, Stud Health Technol Inform, V287, P158, DOI 10.3233/SHTI210837