Development of loop-mediated isothermal amplification for rapid detection of sporotrichosis caused by Sporothrix schenckii

被引:2
作者
Chupia, Vena [1 ,2 ]
Ninsuwon, Jirapat [3 ]
Intanon, Montira [1 ,2 ]
Pikulkaew, Surachai [2 ,4 ]
机构
[1] Chiang Mai Univ, Fac Vet Med, Dept Vet Biosci & Vet Publ Hlth, Chiang Mai 50100, Thailand
[2] Chiang Mai Univ, Fac Vet Med, Res Ctr Producing & Dev Prod & Innovat Anim Hlth &, Chiang Mai 50100, Thailand
[3] Chiang Mai Univ, Anim Hosp, Fac Vet Med, Vet Diagnost Ctr, Chiang Mai 50100, Thailand
[4] Chiang Mai Univ, Fac Vet Med, Dept Food Anim Clin, Chiang Mai 50100, Thailand
关键词
loop -mediated isothermal amplification; molecular detection; rapid detection; Sporothrix schenckii; sporotrichosis; visual detection; MITOCHONDRIAL-DNA ANALYSIS; DIAGNOSIS; LAMP; IDENTIFICATION; SAMPLES; TISSUE;
D O I
10.14202/vetworld.2023.1356-1362
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Background and Aim: Sporothrix schenckii is the causative agent of sporotrichosis, which most commonly causes lymphocutaneous infections in immunocompromised hosts. This pathogen infects dogs, cats, cattle, and buffaloes and can potentially infect humans. Diagnosis by fungal culture is lengthy, and although there are several clinical diagnoses and molecular methods, these are complicated and time-consuming for veterinarians. This study aimed to develop a visual diagnostic assay that is less time-consuming and can be used by veterinarians to screen for sporotrichosis. Materials and Methods: To develop a loop-mediated isothermal amplification (LAMP) assay for sporotrichosis, primers specific for fragments of the 18S rRNA gene of S. schenckii were designed. Then, the time and temperature were optimized to successfully achieve LAMP. Ten-fold serial dilutions of DNA were used to determine the detection limit using both LAMP and nested polymerase chain reaction (nPCR) assays. Results: The optimal LAMP conditions were incubation at 73 & DEG;C for 30 min. Agarose gel electrophoresis revealed a ladder -like pattern of the LAMP product, and a sky-blue color indicated a positive result. A comparison of the LAMP assay with nPCR revealed that it was 10 times more sensitive than nPCR, with a detection limit of 10 pg. The use of a heat box compared with a thermocycler gave the same results. Conclusion: Loop-mediated isothermal amplification gives good results and may represent a future alternative diagnostic tool for screening fungal pathogens before the results of conventional fungal cultures are received. However, this method should be further studied to clarify its use with clinical samples.
引用
收藏
页码:1356 / 1362
页数:7
相关论文
共 35 条
  • [1] Sporotrichosis: A Review of a Neglected Disease in the Last 50 Years in Brazil
    Alvarez, Carmen Magaly
    Oliveira, Manoel Marques Evangelista
    Pires, Regina Helena
    [J]. MICROORGANISMS, 2022, 10 (11)
  • [2] Arenas R, 2007, INT J DERMATOL, V46, P177
  • [3] Buddhachat K., 2022, VET INTEGR SCI, V20, P247
  • [4] Global epidemiology of sporotrichosis
    Chakrabarti, Arunaloke
    Bonifaz, Alexandro
    Gutierrez-Galhardo, Maria Clara
    Mochizuki, Takashi
    Li, Shanshan
    [J]. MEDICAL MYCOLOGY, 2015, 53 (01) : 3 - 14
  • [5] Chupia V., 2019, ASIA LIFE SCI, V28, P175
  • [6] Prevalence of Microsporum canis from Pet Cats in Small Animal Hospitals, Chiang Mai, Thailand
    Chupia, Vena
    Ninsuwon, Jirapat
    Piyarungsri, Kakanang
    Sodarat, Chollada
    Prachasilchai, Worapat
    Suriyasathaporn, Witaya
    Pikulkaew, Surachai
    [J]. VETERINARY SCIENCES, 2022, 9 (01)
  • [7] Chupia Vena, 2019, Veterinary Integrative Sciences, V17, P75
  • [8] Chupia Vena, 2016, Asian Pacific Journal of Tropical Disease, V6, P952, DOI 10.1016/S2222-1808(16)61163-5
  • [9] Cutaneous sporotrichosis in a stray cat from Thailand
    Duangkae, Lerpen
    Yurayart, Chompoonek
    Limsivilai, Orawan
    Chen, Charles
    Kasorndorkbua, Chaiyan
    [J]. MEDICAL MYCOLOGY CASE REPORTS, 2019, 23 : 46 - 49
  • [10] Progress of loop-mediated isothermal amplification technique in molecular diagnosis of plant diseases
    Dung Tien Le
    Nam Tuan Vu
    [J]. APPLIED BIOLOGICAL CHEMISTRY, 2017, 60 (02) : 169 - 180