Experimental temperature evaluation during a robotized bone drilling process

被引:4
作者
Boiadjiev, Tony [1 ]
Boiadjiev, George [2 ,4 ]
Stoimenov, Nikolay [1 ]
Delchev, Kamen [2 ]
Kastelov, Rumen [3 ]
机构
[1] Bulgarian Acad Sci, Inst Informat & Commun Technol, Dept Distributed Informat & Control Syst, Sofia, Bulgaria
[2] Sofia Univ St Kliment Ohridski, Fac Math & Informat, Dept Mechatron Robot & Mech, Sofia, Bulgaria
[3] Minist Domest Affairs, Orthoped & Trauma Clin Ctr, Sofia, Bulgaria
[4] Sofia Univ, Fac Math & informat, Dept Mechatron Robot & Mech, 5 J Boucher Blvd, Sofia 1504, Bulgaria
关键词
Bone drilling; orthopedic robot; temperature evaluation; CORTICAL BONE; PARAMETERS;
D O I
10.1080/13102818.2022.2160276
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A serious problem associated with orthopedic bone drilling manipulation is the so-called thermal osteonecrosis (TO). This problem occurs because the drilling manipulation generates heat, and the amount of heat depends on the drilling conditions. This work presents the experimental evaluation of the temperature during automated bone drilling by using a handheld Orthopedic bone Drilling Robot ODRO. Up to now, such experimental results related to temperature evaluation in bone drilling by robots have not been presented. Fresh porcine and bovine femur bones were specimens in the experiments. The increase in bone temperature during drilling was measured by a thermal infrared camera. Thermographic sequence images were recorded, processed and visualized using specialized software, which allows to capture accurately the moment of drill bit penetration through the bone and its extraction when going back to initial position. The results showed that under given feed rate and drill speed, when using a new drill bit, the temperature value during porcine femur drilling exceeded the critical threshold of 50 degrees C for less than 2 s, and thermal osteonecrosis does not occur. When using a worn-out drill bit, the temperature value during bovine femur drilling significantly exceeded the threshold of 50 degrees C, and thermal osteonecrosis occurs. Thus, to guarantee bone drilling without the risk of thermal osteonecrosis, the automated drilling should be executed with the simultaneous control of speed of drill bit and feed rate. This is possible to be achieved only by robotic execution of the manipulation.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 35 条
[11]   Effects of implant drilling parameters for pilot and twist drills on temperature rise in bone analog and alveolar bones [J].
Chen, Yung-Chuan ;
Hsiao, Chih-Kun ;
Ciou, Ji-Sih ;
Tsai, Yi-Jung ;
Tu, Yuan-Kun .
MEDICAL ENGINEERING & PHYSICS, 2016, 38 (11) :1314-1321
[12]   Reducing temperature elevation of robotic bone drilling [J].
Feldmann, Arne ;
Wandel, Jasmin ;
Zysset, Philippe .
MEDICAL ENGINEERING & PHYSICS, 2016, 38 (12) :1495-1504
[13]   Experimental determination of the emissivity of bone [J].
Feldmann, Arne ;
Zysset, Philippe .
MEDICAL ENGINEERING & PHYSICS, 2016, 38 (10) :1136-1138
[14]  
Fernandes MG., 2018, J Biomech Eng, V2, P69, DOI [10.24243/jmeb/2.5.170, DOI 10.24243/JMEB/2.5.170]
[15]   Inferring material properties in robotic bone drilling processes [J].
Gil, Jorge Juan ;
Diaz, Inaki ;
Accini, Fernando .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2019, 21 (03) :109-118
[16]  
Hou Y., Open Mater Sci J, DOI DOI 10.2174/1874088X01509010178
[17]  
Hou Y., 2016, OPEN MECH ENG J, V10, P109
[18]  
IntelliSense Drill Technology, OUR FOUNDER CEO JOSE
[19]  
Islam M., 2021, J PHYS C SER, V2129
[20]   Comprehensive analysis on orthopedic drilling: A state-of-the-art review [J].
Jamil, Muhammad ;
Rafique, Saima ;
Khan, Aqib Mashood ;
Hegab, Hussien ;
Mia, Mozammel ;
Gupta, Munish Kumar ;
Song, Qinghua .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (06) :537-561