Experimental temperature evaluation during a robotized bone drilling process

被引:4
作者
Boiadjiev, Tony [1 ]
Boiadjiev, George [2 ,4 ]
Stoimenov, Nikolay [1 ]
Delchev, Kamen [2 ]
Kastelov, Rumen [3 ]
机构
[1] Bulgarian Acad Sci, Inst Informat & Commun Technol, Dept Distributed Informat & Control Syst, Sofia, Bulgaria
[2] Sofia Univ St Kliment Ohridski, Fac Math & Informat, Dept Mechatron Robot & Mech, Sofia, Bulgaria
[3] Minist Domest Affairs, Orthoped & Trauma Clin Ctr, Sofia, Bulgaria
[4] Sofia Univ, Fac Math & informat, Dept Mechatron Robot & Mech, 5 J Boucher Blvd, Sofia 1504, Bulgaria
关键词
Bone drilling; orthopedic robot; temperature evaluation; CORTICAL BONE; PARAMETERS;
D O I
10.1080/13102818.2022.2160276
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A serious problem associated with orthopedic bone drilling manipulation is the so-called thermal osteonecrosis (TO). This problem occurs because the drilling manipulation generates heat, and the amount of heat depends on the drilling conditions. This work presents the experimental evaluation of the temperature during automated bone drilling by using a handheld Orthopedic bone Drilling Robot ODRO. Up to now, such experimental results related to temperature evaluation in bone drilling by robots have not been presented. Fresh porcine and bovine femur bones were specimens in the experiments. The increase in bone temperature during drilling was measured by a thermal infrared camera. Thermographic sequence images were recorded, processed and visualized using specialized software, which allows to capture accurately the moment of drill bit penetration through the bone and its extraction when going back to initial position. The results showed that under given feed rate and drill speed, when using a new drill bit, the temperature value during porcine femur drilling exceeded the critical threshold of 50 degrees C for less than 2 s, and thermal osteonecrosis does not occur. When using a worn-out drill bit, the temperature value during bovine femur drilling significantly exceeded the threshold of 50 degrees C, and thermal osteonecrosis occurs. Thus, to guarantee bone drilling without the risk of thermal osteonecrosis, the automated drilling should be executed with the simultaneous control of speed of drill bit and feed rate. This is possible to be achieved only by robotic execution of the manipulation.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 35 条
  • [1] Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A Review
    Akhbar, Mohd Faizal Ali
    Sulong, Akmal Wani
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (01) : 29 - 56
  • [2] Drilling of bone: Effect of drill bit geometries on thermal osteonecrosis risk regions
    Akhbar, Mohd Faizal Ali
    Yusoff, Ahmad Razlan
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (02) : 207 - 218
  • [3] [Anonymous], SMARTDRILL 60 NOW AV
  • [4] Thermal osteonecrosis and bone drilling parameters revisited
    Augustin, Goran
    Davila, Slavko
    Mihoci, Kristijan
    Udiljak, Toma
    Vedrina, Denis Stjepan
    Antabak, Anko
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (01) : 71 - 77
  • [5] Cortical bone drilling and thermal osteonecrosis
    Augustin, Goran
    Zigman, Tomislav
    Davila, Slavko
    Udilljak, Toma
    Staroveski, Tomislav
    Brezak, Danko
    Babic, Slaven
    [J]. CLINICAL BIOMECHANICS, 2012, 27 (04) : 313 - 325
  • [6] Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report
    Augustin, Goran
    Davila, Slavko
    Udiljak, Toma
    Vedrina, Denis Stjepan
    Bagatin, Dinko
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (05) : 703 - 709
  • [7] 3D architecture of Trabecular Bone in the Pig Mandible and Femur: inter-Trabecular angle Distributions
    Ben-Zvi, Yehonatan
    Reznikov, Natalie
    Shahar, Ron
    Weiner, Steve
    [J]. FRONTIERS IN MATERIALS, 2017, 4
  • [8] Boiadjiev T., 2021, LATEST DEV MEDICAL R, P1
  • [9] Feed rate control in robotic bone drilling process
    Boiadjiev, Tony
    Boiadjiev, George
    Delchev, Kamen
    Chavdarov, Ivan
    Kastelov, Roumen
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (03) : 273 - 280
  • [10] Far cortex automatic detection aimed for partial or full bone drilling by a robot system in orthopaedic surgery
    Boiadjiev, Tony
    Boiadjiev, George
    Delchev, Kamen
    Zagurski, Kazimir
    Kastelov, Rumen
    [J]. BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2017, 31 (01) : 200 - 205