The Potential of Adding Mammography to Handheld Ultrasound or Automated Breast Ultrasound to Reduce Unnecessary Biopsies in BI-RADS Ultrasound Category 4a: A Multicenter Hospital-Based Study in China

被引:1
|
作者
Ren, Wenhui [1 ]
Zhao, Xuelian [1 ]
Zhao, Xiaowei [2 ]
Yan, Huijiao [3 ]
Hu, Shangying [1 ]
Qiao, Youlin [3 ]
Xu, Zhijian [2 ]
Zhao, Fanghui [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Canc Hosp, Natl Canc Ctr, Natl Clin Res Ctr Canc,Dept Canc Epidemiol, Beijing 100021, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, Canc Hosp, Natl Clin Res Ctr Canc, Dept Canc Prevent,Natl Canc Ctr, Beijing 100021, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, Sch Populat Med & Publ Hlth, Ctr Global Hlth, Beijing 100730, Peoples R China
关键词
breast neoplasms; ultrasonography; automated breast ultrasound; mammography; diagnosis; VOLUME SCANNER; CANCER; LESIONS; ULTRASONOGRAPHY; MASSES; US; BENIGN; WOMEN; RATES; RISK;
D O I
10.3390/curroncol30030251
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The appropriate management strategies for BI-RADS category 4a lesions among handheld ultrasound (HHUS) remain a matter of debate. We aimed to explore the role of automated breast ultrasound (ABUS) or the second-look mammography (MAM) adjunct to ultrasound (US) of 4a masses to reduce unnecessary biopsies. Women aged 30 to 69 underwent HHUS and ABUS from 2016 to 2017 at five high-level hospitals in China, with those aged 40 or older also accepting MAM. Logistic regression analysis assessed image variables correlated with false-positive lesions in US category 4a. Unnecessary biopsies, invasive cancer (IC) yields, and diagnostic performance among different biopsy thresholds were compared. A total of 1946 women (44.9 +/- 9.8 years) were eligible for analysis. The false-positive rate of category 4a in ABUS was almost 65.81% (77/117), which was similar to HHUS (67.55%; 127/188). Orientation, architectural distortion, and duct change were independent factors associated with the false-positive lesions in 4a of HHUS, whereas postmenopausal, calcification, and architectural distortion were significant features of ABUS (all p < 0.05). For HHUS, both unnecessary biopsy rate and IC yields were significantly reduced when changing biopsy thresholds by adding MAM for US 4a in the total population (scenario #1:BI-RADS 3, 4, and 5; scenario #2: BI-RADS 4 and 5) compared with the current scenario (all p < 0.05). Notably, scenario #1 reduced false-positive biopsies without affecting IC yields when compared to the current scenario for ABUS (p < 0.001; p = 0.125). The higher unnecessary biopsy rate of category 4a by ABUS was similar to HHUS. However, the second-look MAM adjunct to ABUS has the potential to safely reduce false-positive biopsies compared with HHUS.
引用
收藏
页码:3301 / 3314
页数:14
相关论文
共 48 条
  • [21] Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions
    Liu, Hongbiao
    Than, Hongwei
    Sun, Da
    BMC CANCER, 2020, 20 (01)
  • [22] A Single-Center Audit of BI-RADS 3 Assessment Category Utilization in Mammography and Breast Ultrasound
    Common, Jessica
    Abdullah, Peri
    Alabousi, Abdullah
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2023, 74 (01): : 69 - 77
  • [23] Value of ultrasound elastography in diagnosis of BI-RADS 4B breast lesions based on conventional ultrasound
    Gong, Xia
    Wang, Yi
    Wu, Weihua
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 2561 - 2566
  • [24] Predictive value of contrast-enhanced ultrasonography and ultrasound elastography for management of BI-RADS category 4 nonpalpable breast masses
    Niu, Qinghua
    Zhao, Lei
    Wang, Ruitao
    Du, Lianfang
    Shi, Qiusheng
    Jia, Chao
    Li, Gang
    Jin, Lifang
    Li, Fan
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 173
  • [25] Automatic Breast Volume Scanner and B-Ultrasound-Based Radiomics Nomogram for Clinician Management of BI-RADS 4A Lesions
    Ma, Qianqing
    Wang, Junli
    Xu, Daojing
    Zhu, Chao
    Qin, Jing
    Wu, Yimin
    Gao, Yankun
    Zhang, Chaoxue
    ACADEMIC RADIOLOGY, 2023, 30 (08) : 1628 - 1637
  • [26] Histologic work-up of non-palpable breast lesions classified as probably benign at initial mammography and/or ultrasound (BI-RADS category 3)
    Gruber, R.
    Jaromi, S.
    Rudas, M.
    Pfarl, G.
    Riedl, C. C.
    Floery, D.
    Graf, O.
    Sickles, E. A.
    Helbich, T. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (03) : 398 - 403
  • [27] Comparison of conventional and automated breast volume ultrasound in the description and characterization of solid breast masses based on BI-RADS features
    Kim, Hyunji
    Cha, Joo Hee
    Oh, Ha-Yeun
    Kim, Hak Hee
    Shin, Hee Jung
    Chae, Eun Young
    BREAST CANCER, 2014, 21 (04) : 423 - 428
  • [28] Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions
    Hongbiao Liu
    Hongwei Zhan
    Da Sun
    BMC Cancer, 20
  • [29] A multicenter hospital-based diagnosis study of automated breast ultrasound system in detecting breast cancer among Chinese women
    Zhang, Xi
    Lin, Xi
    Tan, Yanjuan
    Zhu, Ying
    Wang, Hui
    Feng, Ruimei
    Tang, Guoxue
    Zhou, Xiang
    Li, Anhua
    Qiao, Youlin
    CHINESE JOURNAL OF CANCER RESEARCH, 2018, 30 (02) : 231 - 239
  • [30] Application of ultrasound artificial intelligence in the differential diagnosis between benign and malignant breast lesions of BI-RADS 4A
    Niu, Sihua
    Huang, Jianhua
    Li, Jia
    Liu, Xueling
    Wang, Dan
    Zhang, Ruifang
    Wang, Yingyan
    Shen, Huiming
    Qi, Min
    Xiao, Yi
    Guan, Mengyao
    Liu, Haiyan
    Li, Diancheng
    Liu, Feifei
    Wang, Xiuming
    Xiong, Yu
    Gao, Siqi
    Wang, Xue
    Zhu, Jiaan
    BMC CANCER, 2020, 20 (01)