Cardiac Damage and Conduction Disorders after Transcatheter Aortic Valve Implantation

被引:5
|
作者
Damas, Francois [1 ]
Nguyen Trung, Mai-Linh [1 ]
Postolache, Adriana [1 ]
Petitjean, Helene [1 ]
Lempereur, Mathieu [1 ]
Viva, Tommaso [1 ,2 ,3 ]
Oury, Cecile [1 ]
Dulgheru, Raluca [1 ]
Lancellotti, Patrizio [1 ]
机构
[1] Univ Liege Hosp, Dept Cardiol, CHU Sart Tilman, GIGA Cardiovasc Sci Liege, B-4000 Liege, Belgium
[2] Univ Milan, Dept Minimally Invas Cardiac Surg, I-20122 Milan, Italy
[3] St Ambrogio Hosp, IRCCS Galeazzi, I-20157 Milan, Italy
关键词
TAVI; cardiac damage; conduction disorders; risk stratification; PACEMAKER IMPLANTATION; CLINICAL IMPACT; DISTURBANCES; REPLACEMENT; STENOSIS; PREVALENCE; GRADIENT;
D O I
10.3390/jcm13020409
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recently, a staging system using 4 grades has been proposed to quantify the extent of cardiac damage associated with aortic stenosis (AS), namely AS-related cardiac damage staging (ASCDS). ASCDS is independently associated with all-cause mortality and important clinical outcomes. To evaluate whether it might be associated with the occurrence of conduction system disorders after TAVI, a total of 119 symptomatic patients with severe AS who underwent a TAVI were categorized according to ASCDS: group 1 (13.5%): no or LV damage; group 2 (58.8%): left atrial/mitral valve damage, atrial fibrillation (AF); group 3 (27.7%): low-flow state, pulmonary vasculature/tricuspid valve/RV damage. After TAVI, 34% of patients exhibited LBBB and 10% high-degree atrioventricular block (HD-AVB). No patient in group 1 developed HD-AVB whereas new LBBB was frequent in groups 2 and 3. Twenty-one patients presented with paroxysmal AF with a higher rate for each group increment (group 1: n = 0, 0%; group 2: n = 11, 15.7%; group 3: n = 10, 30.3%) (p = 0.012). Patients in group 3 had the higher rate of permanent pacemaker implantation (PPMI) (group 1: n = 1, 6.3%; group 2: n = 7, 10%; group 3: n = 9, 27.3%) (p = 0.012). In conclusion, ASCDS might help identify patients at higher risk of conduction disorders and PPMI requirement after TAVI.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Outcome after transvascular transcatheter aortic valve implantation in 2016
    Gaede, Luise
    Blumenstein, Johannes
    Liebetrau, Christoph
    Doerr, Oliver
    Kim, Won-Keun
    Nef, Holger
    Husser, Oliver
    Elsaesser, Albrecht
    Hamm, Christian W.
    Moellmann, Helge
    EUROPEAN HEART JOURNAL, 2018, 39 (08) : 667 - 675
  • [42] Transcatheter aortic valve replacement and cardiac conduction
    Shreenivas, Satya
    Schloss, Edward
    Choo, Joseph
    Sarembock, Ian
    Lilly, Scott
    Kereiakes, Dean
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2019, 17 (04) : 293 - 304
  • [43] Impact of transcatheter aortic valve implantation on surgical aortic valve
    Vaquerizo, Beatriz
    Bleiziffer, Sabine
    Wottke, Michael
    Spaziano, Marco
    Eschenbach, Lena
    Lange, Ruediger
    Piazza, Nicolo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 243 : 145 - 149
  • [44] Conduction disorders after transcatheter aortic valve implantation: A comparison between SAPIEN 3 and SAPIEN 3 Ultra balloon-expandable valves
    Monizzi, Giovanni
    Olivares, Paolo
    Makmur, Giulio
    Fabbiocchi, Franco
    Grancini, Luca
    Mastrangelo, Angelo
    Ferrari, Cristina
    Galli, Stefano
    Montorsi, Piero
    Bartorelli, Antonio L. L.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [45] Transcatheter aortic-valve implantation with or
    Iannopollo, Gianmarco
    Cocco, Marta
    Leone, Alessandro
    Sacca, Salvatore
    Mangino, Domenico
    Picchi, Andrea
    Reccia, Matteo Rocco
    Fineschi, Massimo
    Meliga, Emanuele
    Audo, Andrea
    Nobile, Giampiero
    Tumscitz, Carlo
    Penzo, Carlo
    Saia, Francesco
    Rubboli, Andrea
    Moretti, Carolina
    Vignali, Luigi
    Niccoli, Giampaolo
    Cimaglia, Paolo
    Rognoni, Andrea
    Aschieri, Daniela
    Iaccarino, Daniele
    Ottani, Filippo
    Cavazza, Caterina
    Varbella, Ferdinando
    Secco, Gioel Gabrio
    Bolognese, Leonardo
    Limbruno, Ugo
    Guiducci, Vincenzo
    Campo, Gianluca
    Casella, Gianni
    AMERICAN HEART JOURNAL, 2025, 280 : 7 - 17
  • [46] Delayed Aortic Dissection after Transcatheter Aortic Valve Implantation
    Al-Attar, Nawwar
    Himbert, Dominique
    Barbier, Francois
    Vahanian, Alec
    Nataf, Patrick
    JOURNAL OF HEART VALVE DISEASE, 2013, 22 (05) : 701 - 703
  • [47] Cardiac conduction system disease after transcatheter aortic valve replacement
    Steinberg, Benjamin A.
    Harrison, J. Kevin
    Frazier-Mills, Camille
    Hughes, G. Chad
    Piccini, Jonathan P.
    AMERICAN HEART JOURNAL, 2012, 164 (05) : 664 - 671
  • [48] Atrioventricular conduction in PM recipients after transcatheter aortic valve implantation: Implications using Wenckebach point measurement
    Pelargonio, Gemma
    Scacciavillani, Roberto
    Donisi, Luca
    Narducci, Maria Lucia
    Aurigemma, Cristina
    Pinnacchio, Gaetano
    Bencardino, Gianluigi
    Perna, Francesco
    Spera, Francesco Raffaele
    Comerci, Gianluca
    Ruscio, Eleonora
    Romagnoli, Enrico
    Crea, Filippo
    Burzotta, Francesco
    Trani, Carlo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [49] Conduction disturbances after transcatheter aortic valve implantation procedures - predictors and management
    Wilczek, Krzysztof
    Regula, Rafal
    Bujak, Kamil
    Chodor, Piotr
    Dlugaszek, Michal
    Gasior, Mariusz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2016, 12 (03): : 203 - 211
  • [50] Transcatheter Aortic Valve Implantation in the Elderly: Who to Refer?
    Finn, Matthew
    Green, Philip
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 57 (02) : 215 - 225