Cardiac Damage and Conduction Disorders after Transcatheter Aortic Valve Implantation

被引:5
|
作者
Damas, Francois [1 ]
Nguyen Trung, Mai-Linh [1 ]
Postolache, Adriana [1 ]
Petitjean, Helene [1 ]
Lempereur, Mathieu [1 ]
Viva, Tommaso [1 ,2 ,3 ]
Oury, Cecile [1 ]
Dulgheru, Raluca [1 ]
Lancellotti, Patrizio [1 ]
机构
[1] Univ Liege Hosp, Dept Cardiol, CHU Sart Tilman, GIGA Cardiovasc Sci Liege, B-4000 Liege, Belgium
[2] Univ Milan, Dept Minimally Invas Cardiac Surg, I-20122 Milan, Italy
[3] St Ambrogio Hosp, IRCCS Galeazzi, I-20157 Milan, Italy
关键词
TAVI; cardiac damage; conduction disorders; risk stratification; PACEMAKER IMPLANTATION; CLINICAL IMPACT; DISTURBANCES; REPLACEMENT; STENOSIS; PREVALENCE; GRADIENT;
D O I
10.3390/jcm13020409
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recently, a staging system using 4 grades has been proposed to quantify the extent of cardiac damage associated with aortic stenosis (AS), namely AS-related cardiac damage staging (ASCDS). ASCDS is independently associated with all-cause mortality and important clinical outcomes. To evaluate whether it might be associated with the occurrence of conduction system disorders after TAVI, a total of 119 symptomatic patients with severe AS who underwent a TAVI were categorized according to ASCDS: group 1 (13.5%): no or LV damage; group 2 (58.8%): left atrial/mitral valve damage, atrial fibrillation (AF); group 3 (27.7%): low-flow state, pulmonary vasculature/tricuspid valve/RV damage. After TAVI, 34% of patients exhibited LBBB and 10% high-degree atrioventricular block (HD-AVB). No patient in group 1 developed HD-AVB whereas new LBBB was frequent in groups 2 and 3. Twenty-one patients presented with paroxysmal AF with a higher rate for each group increment (group 1: n = 0, 0%; group 2: n = 11, 15.7%; group 3: n = 10, 30.3%) (p = 0.012). Patients in group 3 had the higher rate of permanent pacemaker implantation (PPMI) (group 1: n = 1, 6.3%; group 2: n = 7, 10%; group 3: n = 9, 27.3%) (p = 0.012). In conclusion, ASCDS might help identify patients at higher risk of conduction disorders and PPMI requirement after TAVI.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Predictors and Permanency of Cardiac Conduction Disorders and Necessity of Pacing after Transcatheter Aortic Valve Implantation
    Boerlage-Van Dijk, Kirsten
    Kooiman, Kirsten M.
    Yong, Ze Yie
    Wiegerinck, Esther M. A.
    Damman, Peter
    Bouma, Berto J.
    Tijssen, Jan G. P.
    Piek, Jan J.
    Knops, Reinoud E.
    Baan, Jan, Jr.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (11): : 1520 - 1529
  • [2] Anatomical predictors of conduction damage after transcatheter implantation of the aortic valve
    Tretter, Justin T.
    Mori, Shumpei
    Anderson, Robert H.
    Taylor, Michael D.
    Ollberding, Nicholas
    Truong, Vien
    Choo, Joseph
    Kereiakes, Dean
    Mazur, Wojciech
    OPEN HEART, 2019, 6 (01):
  • [3] Conduction disorders after transcatheter aortic valve implantation: A focused review
    McDonnell K.M.W.
    Shepard R.K.
    Current Treatment Options in Cardiovascular Medicine, 2013, 15 (4) : 488 - 496
  • [4] Management of conduction disorders after transcatheter aortic valve implantation: results of the EHRA survey
    Badertscher, Patrick
    Knecht, Sven
    Zeljkovie, Ivan
    Sticherling, Christian
    de Asmundis, Carlo
    Conte, Giulio
    Barra, Sergio
    Jedrzej, Kosiuk
    Kuehne, Michael
    Boveda, Serge
    EUROPACE, 2022, : 1179 - 1185
  • [5] Incidence, Predictors, and Outcome of Conduction Disorders After Transcatheter Self-Expandable Aortic Valve Implantation
    Fraccaro, Chiara
    Buja, Gianfranco
    Tarantini, Giuseppe
    Gasparetto, Valeria
    Leoni, Loira
    Razzolini, Renato
    Corrado, Domenico
    Bonato, Raffaele
    Basso, Cristina
    Thiene, Gaetano
    Gerosa, Gino
    Isabella, Giambattista
    Iliceto, Sabin
    Napodano, Massimo
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (05) : 747 - 754
  • [6] Conduction disorders in the setting of transcatheter aortic valve implantation: a clinical perspective
    Fraccaro, Chiara
    Napodano, Massimo
    Tarantini, Giuseppe
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (07) : 1217 - 1223
  • [7] Atrioventricular Conduction After Transcatheter Aortic Valve Implantation and Surgical Aortic Valve Replacement
    Roten, Laurent
    Stortecky, Stefan
    Scarcia, Flavio
    Kadner, Alexander
    Tanner, Hildegard
    Delacretaz, Etienne
    Meier, Bernhard
    Windecker, Stephan
    Carrel, Thierry
    Wenaweser, Peter
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (10) : 1115 - 1122
  • [8] Conduction recovery and avoidance of permanent pacing after transcatheter aortic valve implantation
    Marzahn, Corinne
    Koban, Cornel
    Seifert, Martin
    Isotani, Akihiro
    Neuss, Michael
    Hoeschermann, Frank
    Butter, Christian
    JOURNAL OF CARDIOLOGY, 2018, 71 (1-2) : 101 - 108
  • [9] Impact of early changes in cardiac damage following transcatheter aortic valve implantation
    Zhou, Yaoyao
    Zhu, Qifeng
    Lin, Xinping
    Li, Huajun
    Pu, Zhaoxia
    Liu, Xianbao
    Wang, Jian'an
    EUROINTERVENTION, 2023, 19 (03) : 267 - +
  • [10] Extent of Cardiac Damage and Mortality in Patients Undergoing Transcatheter Aortic Valve Implantation
    Avvedimento, Marisa
    Franzone, Anna
    Leone, Attilio
    Piccolo, Raffaele
    Castiello, Domenico Simone
    Ilardi, Federica
    Mariani, Andrea
    Esposito, Roberta
    Iapicca, Cristina
    Angellotti, Domenico
    Scalamogna, Maria
    Santoro, Ciro
    Di Serafino, Luigi
    Cirillo, Plinio
    Esposito, Giovanni
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (19)