The impacts of registration-and-fixation device positioning on the performance of implant placement assisted by dynamic computer-aided surgery: A randomized controlled trial

被引:3
|
作者
Wu, Bin-Zhang [1 ,2 ,3 ,4 ]
Sun, Feng [1 ]
机构
[1] Peking Univ Sch & Hosp Stomatol, Clin Div 1, 37A Xishiku St, Beijing 100034, Peoples R China
[2] Natl Ctr Stomatol, 37A Xishiku St, Beijing 100034, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, 37A Xishiku St, Beijing 100034, Peoples R China
[4] Natl Engn Res Ctr Oral Biomat & Digital Med Device, 37A Xishiku St, Beijing 100034, Peoples R China
关键词
accuracy; dynamic navigation; implant surgery; registration; registration-and-fixation; two-in-one; SURGICAL NAVIGATION; ACCURACY; SPLINT;
D O I
10.1111/clr.14237
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesTo assess the efficacy of dynamic computer-aided surgery (dCAS) in replacing a single missing posterior tooth, we compare outcomes when using registration-and-fixation devices positioned anterior or posterior to the surgical site. Registration is performed on either the anterior or opposite posterior teeth.MethodsForty individuals needing posterior single-tooth implant placement were randomly assigned to anterior or posterior registration. Nine parameters were analyzed to detect the deviations between planned and actual implant placement, using Mann-Whitney and t-tests for nonnormally and normally distributed data, respectively.ResultsThe overall average angular deviation for this study was 2.08 +/- 1.12 degrees, with the respective average 3D platform and apex deviations of 0.77 +/- 0.32 mm and 0.88 +/- 0.32 mm. Angular deviation values for individuals in the anterior and posterior registration groups were 1.58 degrees(IQR: 0.98 degrees-2.38 degrees) and 2.25 degrees(IQR: 1.46 degrees-3.43 degrees), respectively (p = .165), with 3D platform deviations of 0.81 +/- 0.29 mm and 0.74 +/- 0.36 mm (p = .464), as well as 3D apex deviations of 0.89 +/- 0.32 mm and 0.88 +/- 0.33 mm (p = .986). No significant variations in absolute buccolingual (platform, p = .659; apex, p = .063), apicocoronal (platform, p = .671; apex, p = .649), or mesiodistal (platform, p = .134; apex, p = .355) deviations were observed at either analyzed levels.ConclusionsBoth anterior and posterior registration approaches facilitate accurate dCAS-mediated implant placement for single missing posterior teeth. The device's placement (posterior-to or anterior-to the surgical site) did not affect the clinician's ability to achieve the planned implant location.
引用
收藏
页码:386 / 395
页数:10
相关论文
共 21 条
  • [1] Investigational Clinical Trial of a Prototype Optoelectronic Computer-Aided Navigation Device for Dental Implant Surgery
    Jokstad, Asbjorn
    Winnett, Brenton
    Fava, Joseph
    Powell, David
    Somogyi-Ganss, Eszter
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (03) : 679 - 692
  • [2] Accuracy of implant placement with a combined use of static and dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial
    Yotpibulwong, Thanida
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Sinpitaksakul, Phonkit
    Arksornnukit, Mansuang
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (04) : 330 - 341
  • [3] The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis
    Fan, Shengchi
    Saenz-Ravello, Gustavo
    Diaz, Leonardo
    Wu, Yiqun
    Davo, Ruben
    Wang, Feng
    Magic, Marko
    Al-Nawas, Bilal
    Kaemmerer, Peer W.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (16)
  • [4] Implant position accuracy using dynamic computer-assisted implant surgery (CAIS) combined with augmented reality: A randomized controlled clinical trial
    Arunjaroensuk, Sirida
    Yotpibulwong, Thanida
    Fu, Po-Sung
    Wang, Jen-Chyan
    Hung, Chun-Cheng
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    JOURNAL OF DENTAL SCIENCES, 2024, 19 : S44 - S50
  • [5] Randomized Controlled Clinical Trial to Assess the Utility of Computer-Aided Intraoperative Navigation in Bimaxillary Orthognathic Surgery
    Chen, Chen
    Sun, Ningning
    Jiang, Chunmiao
    Sun, Jian
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (06) : 2205 - 2209
  • [6] The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial
    Kaewsiri, Dechawat
    Panmekiate, Soontra
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (06) : 505 - 514
  • [7] Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials
    Khaohoen, Angkoon
    Powcharoen, Warit
    Sornsuwan, Tanapon
    Chaijareenont, Pisaisit
    Rungsiyakull, Chaiy
    Rungsiyakull, Pimduen
    BMC ORAL HEALTH, 2024, 24 (01)
  • [8] Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials
    Angkoon Khaohoen
    Warit Powcharoen
    Tanapon Sornsuwan
    Pisaisit Chaijareenont
    Chaiy Rungsiyakull
    Pimduen Rungsiyakull
    BMC Oral Health, 24
  • [9] Training of novice surgeons using dynamic computer assisted dental implant surgery: An exploratory randomized trial
    Kunakornsawat, Wirawat
    Serichetaphongse, Pravej
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (03) : 511 - 518
  • [10] Clinical study of immediate implant placement in posterior maxillary region assisted by dynamic real-time navigation: A randomized controlled trial
    Yang, Yun
    Geng, Ningbo
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2024, 125 (05)