Impact of support instruments in medial closed-wedge distal femoral osteotomy: a finite element analysis

被引:1
|
作者
Kuwashima, Umito [1 ]
Itoh, Masafumi [1 ]
Itou, Junya [1 ]
Okazaki, Ken [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Orthopaed Surg, 8-1 Kawada Cho,Shinjuku Ku, Tokyo 1628666, Japan
关键词
Medial closed-wedge distal femoral osteotomy; Valgus alignment; Hinge fracture; Finite element analysis; Support instrument; MECHANICAL-PROPERTIES; FIXATION; DENSITY; BONE;
D O I
10.1007/s00402-023-05152-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionMedial closed-wedge distal femoral osteotomy (MCWDFO) is a valuable treatment approach for lateral knee osteoarthritis with femoral valgus deformity. Improved results have been reported with the upgrade of surgical techniques and locking plates. However, the risk of nonunion and loss of correction increases in cases of lateral hinge fractures. This study aimed to evaluate the mechanical impact of hinge fractures and support instruments in MCWDFO using finite element analysis (FEA).Materials and methodsFive femur models were developed using Mechanical Finder 11.0 FEA software. We simulated the following models: only a medial locking plate (MLP) (group A); an MLP with a lateral support screw (group B); and an MLP with a lateral support plate (group C). The equivalent stress around the hinge was evaluated and the percentage of the plastic deformation zone was calculated for the hinge area in the no-hinge fracture model. The equivalent stress of the MLP and the degree of displacement were calculated using the hinge fracture model.ResultsThe percentages of the plastic deformation zone in groups A, B, and C were 18.0 +/- 11.7%, 3.3 +/- 2.4%, and 2.3 +/- 2.8%, respectively. The percentages tended to be lower in groups B and C than in group A. In the hinge fracture model, the mean equivalent stress of the MLP in group C was significantly less than that in group A. In terms of the mean degree of displacement, group A showed more than 1 mm of displacement, which was significantly larger than that of the other groups.ConclusionThe support instruments provided stability to the hinge site and reduced the equivalent stress of the main plate in the MCWDFO with hinge fractures. No significant difference was observed between the two instruments in terms of stability.
引用
收藏
页码:1039 / 1045
页数:7
相关论文
共 50 条
  • [41] Medial closing-wedge distal femoral varus osteotomy: Symptoms and functional impact in cases of associated patellofemoral osteoarthritis. A two-year follow-up prospective pilot study
    Barnavon, T.
    Odri, G. A.
    Vendeuvre, T.
    Labrada-Blanco, O.
    Bordes, M.
    Renard, G.
    Rouvillain, J. L.
    Severyns, M.
    KNEE, 2020, 27 (03) : 615 - 623
  • [42] Finite element analysis of plate-screw systems used in medial opening wedge proximal tibial osteotomies
    Kimsal, Julie
    Mercer, Deana
    Schenck, Robert
    DeCoster, Thomas
    Bozorgnia, Shahram
    Fitzpatrick, Jennifer
    Mlady, Gary
    Lerma, Jesus
    Khraishi, Tariq
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2015, 19 (02) : 154 - 168
  • [43] Finite element analysis of the impact of screw insertion distal to the trochanter minor on the risk of iatrogenic subtrochanteric fracture
    Sensoz, Ersin
    Ozkal, Fatih Mehmet
    Acar, Volkan
    Cakir, Ferit
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (08) : 807 - 818
  • [44] Positive medial cortical support versus anatomical reduction for trochanteric hip fractures: Finite element analysis and biomechanical testing
    Mao, Wei
    Chang, Shi-min
    Zhang, Ying-qi
    Li, Yan
    Du, Shou-chao
    Hu, Sun-jun
    Yang, Aolei
    Zhou, Kai-hua
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 234
  • [45] Sagittal support rather than medial cortical support matters in geriatric intertrochanteric fracture: A finite element analysis study
    Liu, Jixuan
    Ge, Yufeng
    Wang, Yu
    Yang, Qing
    Yibulayimu, Sutuke
    Wu, Xinbao
    Tian, Wei
    Shi, Chao
    Liu, Yanzhen
    Yang, Minghui
    HELIYON, 2024, 10 (07)
  • [46] Positive or negative anteromedial cortical support of unstable pertrochanteric femoral fractures: A finite element analysis study
    Shao, Qin
    Zhang, Yue
    Sun, Gui-Xin
    Yang, Chen-Song
    Liu, Na
    Chen, Da-Wei
    Cheng, Biao
    BIOMEDICINE & PHARMACOTHERAPY, 2021, 138
  • [47] The effect of rotational degree and routine activity on the risk of collapse in transtrochanteric rotational osteotomy for osteonecrosis of the femoral head—a finite element analysis
    Pusheng Xie
    Yuping Deng
    Jinchuan Tan
    Mian Wang
    Yang Yang
    Hanbin Ouyang
    Wenhua Huang
    Medical & Biological Engineering & Computing, 2020, 58 : 805 - 814
  • [48] Biomechanical research of medial femoral circumflex vascularized bone-grafting in the treatment of early-to-mid osteonecrosis of the femoral head: a finite element analysis
    Yingkai Zhang
    Xinyuan Wang
    Chang Jiang
    Bingxuan Hua
    Zuoqin Yan
    Journal of Orthopaedic Surgery and Research, 17
  • [49] Location or size? A finite element analysis study of necrotic lesion impact on femoral head collapse
    Lu, Shun
    Lin, Tianye
    Han, Longfei
    Li, Ziqi
    He, Mingcong
    Wei, Qiushi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [50] Biomechanical research of medial femoral circumflex vascularized bone-grafting in the treatment of early-to-mid osteonecrosis of the femoral head: a finite element analysis
    Zhang, Yingkai
    Wang, Xinyuan
    Jiang, Chang
    Hua, Bingxuan
    Yan, Zuoqin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)