Impact of support instruments in medial closed-wedge distal femoral osteotomy: a finite element analysis

被引:1
|
作者
Kuwashima, Umito [1 ]
Itoh, Masafumi [1 ]
Itou, Junya [1 ]
Okazaki, Ken [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Orthopaed Surg, 8-1 Kawada Cho,Shinjuku Ku, Tokyo 1628666, Japan
关键词
Medial closed-wedge distal femoral osteotomy; Valgus alignment; Hinge fracture; Finite element analysis; Support instrument; MECHANICAL-PROPERTIES; FIXATION; DENSITY; BONE;
D O I
10.1007/s00402-023-05152-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionMedial closed-wedge distal femoral osteotomy (MCWDFO) is a valuable treatment approach for lateral knee osteoarthritis with femoral valgus deformity. Improved results have been reported with the upgrade of surgical techniques and locking plates. However, the risk of nonunion and loss of correction increases in cases of lateral hinge fractures. This study aimed to evaluate the mechanical impact of hinge fractures and support instruments in MCWDFO using finite element analysis (FEA).Materials and methodsFive femur models were developed using Mechanical Finder 11.0 FEA software. We simulated the following models: only a medial locking plate (MLP) (group A); an MLP with a lateral support screw (group B); and an MLP with a lateral support plate (group C). The equivalent stress around the hinge was evaluated and the percentage of the plastic deformation zone was calculated for the hinge area in the no-hinge fracture model. The equivalent stress of the MLP and the degree of displacement were calculated using the hinge fracture model.ResultsThe percentages of the plastic deformation zone in groups A, B, and C were 18.0 +/- 11.7%, 3.3 +/- 2.4%, and 2.3 +/- 2.8%, respectively. The percentages tended to be lower in groups B and C than in group A. In the hinge fracture model, the mean equivalent stress of the MLP in group C was significantly less than that in group A. In terms of the mean degree of displacement, group A showed more than 1 mm of displacement, which was significantly larger than that of the other groups.ConclusionThe support instruments provided stability to the hinge site and reduced the equivalent stress of the main plate in the MCWDFO with hinge fractures. No significant difference was observed between the two instruments in terms of stability.
引用
收藏
页码:1039 / 1045
页数:7
相关论文
共 50 条
  • [21] Finite Element Analysis of Optimal Positioning of Femoral Osteotomy in Total Hip Arthroplasty With Subtrochanteric Shortening
    Takahashi, Daisuke
    Noyama, Yoshihiro
    Shimizu, Tomohiro
    Terkawi, Mohamad Alaa
    Iwasaki, Norimasa
    ARTHROPLASTY TODAY, 2022, 14 : 105 - 109
  • [22] Mechanical stability of the proximal tibia with different bone formations after plate removal in medial opening-wedge high tibial osteotomy: a finite element analysis
    Jang, Chul-Young
    Kang, Kyoung-Tak
    Hong, Hyongtaek
    Jung, Min
    Kim, Sungjun
    Yoo, Je-Hyun
    Kim, Sung-Hwan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [23] Both medial closing wedge and lateral opening wedge distal femoral osteotomy for valgus knee deformity can maintain leg length: A radiographic comparative study
    Onishi, Shintaro
    Kim, Youngji
    Adebayo, Oliver
    Nakayama, Hiroshi
    Jacquet, Christophe
    Ollivier, Matthieu
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2025, 12 (01)
  • [24] Application of Finite Element Analysis Combined With Virtual Computer in Preoperative Planning of Distal Femoral Fracture
    He, Yuanming
    Liu, Yang
    Yin, Bo
    Wang, Dong
    Wang, Hanzhou
    Yao, Peifeng
    Zhou, Junlin
    FRONTIERS IN SURGERY, 2022, 9
  • [25] Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis
    Yang, Pan
    Zhang, Ying
    Liu, Jian
    Xiao, Jin
    Ma, Li Min
    Zhu, Chang Rong
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2015, 49 (02) : 203 - 209
  • [26] Finite Element Analysis of Acetabular Medial Wall Displacement Osteotomy in Adult Acetabular Dysplasia
    Li DongSong
    Li ShuQiang
    Cai Bo
    Yang Chen
    Liu Jian Guo
    MECHANICAL ENGINEERING AND MATERIALS, PTS 1-3, 2012, 152-154 : 1353 - +
  • [27] Computer-aided Design of Distal Femoral Osteotomy for the Valgus Knee and Effect of Correction Angle on Joint Loading by Finite Element Analysis
    Wu, Yanfei
    Jin, Xin
    Zhao, Xingwen
    Wang, Ying
    Bai, Haohao
    Lu, Bin
    Tong, Xue
    Ma, Jianxiong
    Ma, Xinlong
    ORTHOPAEDIC SURGERY, 2022, 14 (11) : 2904 - 2913
  • [28] Finite Element Analysis of Optimal Design of Distal Geometry of Cementless Femoral Prosthesis
    Zhao, Y.
    Wang, L.
    Bao, Y.
    Xu, R.
    He, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (09) : 1476 - 1483
  • [29] Biomechanical evaluation of opening-wedge high tibial osteotomy with composite materials using finite-element analysis
    Koh, Yong-Gon
    Son, Juhyun
    Kwon, Sae Kwang
    Kim, Hyo Jeong
    Kang, Kyoung-Tak
    KNEE, 2018, 25 (06) : 977 - 987
  • [30] Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis
    Zhang, Jun
    Wei, Yan
    Li, Guoding
    Wang, Jian
    Xu, Youjia
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2021, 55 (01) : 9 - 15