Impact of support instruments in medial closed-wedge distal femoral osteotomy: a finite element analysis

被引:1
|
作者
Kuwashima, Umito [1 ]
Itoh, Masafumi [1 ]
Itou, Junya [1 ]
Okazaki, Ken [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Orthopaed Surg, 8-1 Kawada Cho,Shinjuku Ku, Tokyo 1628666, Japan
关键词
Medial closed-wedge distal femoral osteotomy; Valgus alignment; Hinge fracture; Finite element analysis; Support instrument; MECHANICAL-PROPERTIES; FIXATION; DENSITY; BONE;
D O I
10.1007/s00402-023-05152-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionMedial closed-wedge distal femoral osteotomy (MCWDFO) is a valuable treatment approach for lateral knee osteoarthritis with femoral valgus deformity. Improved results have been reported with the upgrade of surgical techniques and locking plates. However, the risk of nonunion and loss of correction increases in cases of lateral hinge fractures. This study aimed to evaluate the mechanical impact of hinge fractures and support instruments in MCWDFO using finite element analysis (FEA).Materials and methodsFive femur models were developed using Mechanical Finder 11.0 FEA software. We simulated the following models: only a medial locking plate (MLP) (group A); an MLP with a lateral support screw (group B); and an MLP with a lateral support plate (group C). The equivalent stress around the hinge was evaluated and the percentage of the plastic deformation zone was calculated for the hinge area in the no-hinge fracture model. The equivalent stress of the MLP and the degree of displacement were calculated using the hinge fracture model.ResultsThe percentages of the plastic deformation zone in groups A, B, and C were 18.0 +/- 11.7%, 3.3 +/- 2.4%, and 2.3 +/- 2.8%, respectively. The percentages tended to be lower in groups B and C than in group A. In the hinge fracture model, the mean equivalent stress of the MLP in group C was significantly less than that in group A. In terms of the mean degree of displacement, group A showed more than 1 mm of displacement, which was significantly larger than that of the other groups.ConclusionThe support instruments provided stability to the hinge site and reduced the equivalent stress of the main plate in the MCWDFO with hinge fractures. No significant difference was observed between the two instruments in terms of stability.
引用
收藏
页码:1039 / 1045
页数:7
相关论文
共 50 条
  • [1] Impact of support instruments in medial closed-wedge distal femoral osteotomy: a finite element analysis
    Umito Kuwashima
    Masafumi Itoh
    Junya Itou
    Ken Okazaki
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1039 - 1045
  • [2] Quantitative analysis of protective Kirschner wire diameters in lateral opening wedge distal femoral osteotomy: A finite element study
    Baris, Alican
    Ozmen, Emre
    Circi, Esra
    Yuksel, Serdar
    Beytemur, Ozan
    JOINT DISEASES AND RELATED SURGERY, 2025, 36 (01) : 97 - 106
  • [3] Biomechanical analysis of the role of hinge support fixators on hinge stability in medial closing wedge distal femoral osteotomy
    Matsushita, Takehiko
    Akiyama, Takenori
    Osano, Kei
    Yokoyama, Yasuharu
    Okazaki, Ken
    CLINICAL BIOMECHANICS, 2022, 91
  • [4] Optimal additional support screw position for prevention of hinge fracture in biplanar closed wedge distal femoral osteotomy
    Higa, Masaru
    Nakayama, Hiroshi
    Kanto, Ryo
    Onishi, Shintaro
    Yoshiya, Shinichi
    Tachibana, Toshiya
    Iseki, Tomoya
    JOURNAL OF ORTHOPAEDICS, 2023, 43 : 1 - 5
  • [5] Soft tissue stabilization of the hinge position in medial closed wedge distal femoral osteotomy: an anatomical study
    Oda, Taiga
    Maeyama, Akira
    Yoshimura, Ichiro
    Ishimatsu, Tetsuro
    Miyazaki, Kotaro
    Tachibana, Katsuro
    Yoshimitsu, Kengo
    Yamamoto, Takuaki
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [6] Soft tissue stabilization of the hinge position in medial closed wedge distal femoral osteotomy: an anatomical study
    Taiga Oda
    Akira Maeyama
    Ichiro Yoshimura
    Tetsuro Ishimatsu
    Kotaro Miyazaki
    Katsuro Tachibana
    Kengo Yoshimitsu
    Takuaki Yamamoto
    BMC Musculoskeletal Disorders, 23
  • [7] Finite element analysis of medial closing and lateral opening wedge osteotomies of the distal femur in relation to hinge fractures
    Meisterhans, Michel
    Flury, Andreas
    Zindel, Christoph
    Zimmermann, Stefan M.
    Vlachopoulos, Lazaros
    Snedeker, Jess G.
    Fucentese, Sandro F.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [8] Comparing Simulation Approaches Used in Finite Element Modelling of a Medial Opening Wedge High Tibial Osteotomy
    Carranza, Victor A.
    Getgood, Alan
    Willing, Ryan
    Burkhart, Timothy A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2025, 53 (03) : 731 - 739
  • [9] Hinge fracture in lateral closed-wedge distal femoral osteotomy in knees undergoing double-level osteotomy: assessment of postoperative change in rotational alignment using CT evaluation
    Hiroshi Nakayama
    Ryo Kanto
    Shintaro Onishi
    Shunichiro Kambara
    Kenta Amai
    Shinichi Yoshiya
    Steffen Schröter
    Toshiya Tachibana
    Tomoya Iseki
    Knee Surgery, Sports Traumatology, Arthroscopy, 2021, 29 : 3337 - 3345
  • [10] Assessing the Local Mechanical Environment in Medial Opening Wedge High Tibial Osteotomy Using Finite Element Analysis
    Pauchard, Yves
    Ivanov, Todor G.
    McErlain, David D.
    Milner, Jaques S.
    Giffin, J. Robert
    Birmingham, Trevor B.
    Holdsworth, David W.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (03):