Comparison of Different Internal Limiting Membrane Peeling Sizes for Idiopathic Macular Holes: A Systematic Review and Meta-Analysis

被引:1
|
作者
Qi, Biying [1 ,2 ]
Zhang, Ke [1 ,2 ]
Yang, Xiaohan [1 ,2 ]
Wu, Xijin [1 ,2 ]
Wang, Xinbo [1 ,2 ]
Liu, Wu [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China
[2] Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
关键词
Macular hole; Internal limiting membrane; Vitrectomy; Closure rate; Visual acuity; OPTICAL COHERENCE TOMOGRAPHY; BRILLIANT BLUE-G; INDOCYANINE GREEN; OUTCOMES; SURGERY; VITRECTOMY; EYES; ILM;
D O I
10.1159/000531510
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Although internal limiting membrane (ILM) peeling facilitates macular hole (MH) closure and reduces late hole reopening, it brings some detrimental consequences to the retinal microstructure and functional outcomes. So far, previous studies have not reached a consensus on the optimal ILM peeling size. Objectives: The objective of this study was to evaluate the outcomes of different ILM peeling sizes for idiopathic MHs. Methods: PubMed, Embase, Cochrane Library, Web of Science, CNKI, and WANFANG were searched until April 10, 2022. Studies in English or Chinese that compare the effects of two ILM peeling sizes (>2 disk diameters [DDs] vs. <= 2DD) for idiopathic MHs were included. The overall closure rate, postoperative best-corrected visual acuity (BCVA), type 1 closure, and adverse events were extracted. BCVA was converted to logarithm of the minimum angle of resolution (LogMAR). Results: Seven eligible studies (560 eyes) including 3 randomized clinical trials, 3 prospective trials, and one retrospective cohort were included. Pooled results showed a significantly better postoperative BCVA (mean difference = -0.16; 95% confidence interval [CI]: -0.27 to -0.04; LogMAR) and higher type 1 closure rate (risk ratio [RR] = 1.24; 95% CI: 1.08-1.43) in eyes with ILM peeling >2DD than those with peeling <= 2DD. No significant difference was found in overall closure rate and adverse events between the two groups. Subgroup analysis indicated that in MHs >400 mu m, peeling >2DD helped obtain a better postoperative BCVA (mean difference = -0.17; 95% CI: -0.29 to -0.04; LogMAR) and higher frequency of type 1 closure (RR = 1.25; 95% CI: 1.03-1.51). Conclusions: Peeling >2DD shares similar safety level with peeling <= 2DD and has a superiority of facilitating visual recovery. Larger ILM peeling may be more beneficial for large MHs.
引用
收藏
页码:1071 / 1084
页数:14
相关论文
共 50 条
  • [41] Outcomes of idiopathic macular epiretinal membrane removal with and without internal limiting membrane peeling: A comparative study
    Lee, Ji Woong
    Kim, In Taek
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (02) : 129 - 134
  • [42] Long-term functional and anatomical evolution in surgically closed macular holes with internal limiting membrane peeling
    Eymard, Pauline
    Le Mer, Yannick
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (05) : 1112 - 1119
  • [43] Clinicopathological study of the idiopathic macular hole: Comparison of epiretinal membrane peeling and internal limiting membrane peeling
    Kuo, HK
    Lin, JW
    Kao, ML
    Liu, CC
    OPHTHALMOLOGICA, 2004, 218 (01) : 31 - 35
  • [44] Effect of Internal Limiting Membrane Peeling on Macular Structure and Metamorphopsia Scores in Idiopathic Epiretinal Membrane Surgery
    Aydin, Tekin
    Kerci, Suleyman Gokhan
    Karti, Omer
    Zengin, Mehmet Ozgur
    Kusbeci, Tuncay
    OPEN OPHTHALMOLOGY JOURNAL, 2020, 14 : 1 - 8
  • [45] Efficacy and safety of vitrectomy with internal limiting membrane peeling for diabetic macular edema: a Meta-analysis
    Xin-Ying Hu
    Huan Liu
    Li-Na Wang
    Yu-Zhi Ding
    Jie Luan
    International Journal of Ophthalmology, 2018, 11 (11) : 1848 - 1855
  • [46] Autologous internal limiting membrane transplant for recurrent idiopathic macular holes
    Rossi, Tommaso
    Trillo, Carlandrea
    Ripandelli, Guido
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (02) : 656 - 663
  • [47] Indocyanine green-assisted internal limiting membrane peeling for macular holes - Toxicity?
    Mavrofrides, Elias
    Smiddy, William E.
    Kitchens, John W.
    Salicone, Alberto
    Feuer, William
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (06): : 637 - 644
  • [48] Vitrectomy with inverted internal limiting membrane flap versus internal limiting membrane peeling for macular hole retinal detachment in high myopia: a systematic review of literature and meta-analysis
    Xu, Qian
    Luan, Jie
    EYE, 2019, 33 (10) : 1626 - 1634
  • [49] Retinal Ganglion Cell Complex Thickness after Internal Limiting Membrane Peeling for Idiopathic Macular Hole
    Sheng, Yan
    Tong, Jian-Ping
    CURRENT EYE RESEARCH, 2014, 39 (05) : 537 - 538
  • [50] INTERNAL LIMITING MEMBRANE PEELING AND AIR TAMPONADE FOR STAGE III AND STAGE IV IDIOPATHIC MACULAR HOLE
    Yu, Yanping
    Liang, Xida
    Wang, Zengyi
    Wang, Jing
    Liu, Xinxin
    Chen, Jinqiu
    Liu, Wu
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (01): : 66 - 74