Empirical fragility and ROC curves for masonry buildings subjected to settlements

被引:6
|
作者
Prosperi, Alfonso [1 ,2 ]
Korswagen, Paul A. [1 ,2 ]
Korff, Mandy [1 ,2 ,3 ]
Schipper, Roel [1 ,2 ]
Rots, Jan G. [1 ,2 ]
机构
[1] Delft Univ Technol, Fac Civil Engn & Geosci, Stevinweg 1, NL-2628 CN Delft, Netherlands
[2] Delft Univ Technol, Fac Civil Engn & Geosci, Stevinweg 1, NL-2600 GA Delft, Netherlands
[3] Deltares, POB 177, NL-2600 MH Delft, Netherlands
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 68卷
基金
荷兰研究理事会;
关键词
Masonry buildings; Damage assessment; Fragility curves; ROC curve; Settlement trough; LAND SUBSIDENCE; DAMAGE; DESIGN; AREAS; DELTA;
D O I
10.1016/j.jobe.2023.106094
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the Netherlands, the potential damage to the building stock due to subsidence phenomena has recently received increased awareness. However, evaluating and predicting damage to buildings in subsiding areas is a complex task that requires associating the vulnerability of exposed structures with the intensity of the subsidence hazard. Considering the widespread presence of subsidence-related damage to the built heritage, the focus of this study is to provide empiricalbased insights to assess and forecast subsidence damage to masonry buildings. A rich dataset with manual levelling measurements was collected comprising 386 surveyed masonry buildings, mainly low-rise (terraced) houses built before 1950. Of the total set of buildings, 122 cases rest on shallow foundations and 264 on piled foundations. For each building, the recorded damage is related to the settlement, calculated from the bed-joint levelling measurements, using four different intensity parameters, namely differential settlement, rotation, relative rotation and deflection ratio. These four parameters are appraised in their capacity to effectively predict the intensity of the damage. The Receiver Operating Characteristic (ROC) method is used to evaluate the relative efficacy of the selected hazard parameters. The rotation, the relative rotation (angular distortion) and the deflection ratio are observed as the most accurate when predicting the intensity of damage, while the differential settlement appears less accurate. Additionally, the dataset was used to generate empirical fragility curves where the probability of damage is described as a function of the aforementioned parameters. Thresholds were set to distinguish between the light damage and the functional and structural damage state. At a relative rotation of 1/500 masonry buildings on shallow foundations were observed to reach or exceed light damage with a probability of 13%, and functional and structural damage with 5%. The availability of the bed joint levelling measurements made it possible to classify eight recurrent settlement profiles, including both symmetric and asymmetric profiles, associated with both the overall deformation and the rigid rotations of the surveyed buildings.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Fragility curves for old masonry building types in Lisbon
    Simoes, Ana
    Milosevic, Jelena
    Meireles, Helena
    Bento, Rita
    Cattari, Serena
    Lagomarsino, Sergio
    BULLETIN OF EARTHQUAKE ENGINEERING, 2015, 13 (10) : 3083 - 3105
  • [22] Fragility curves for old masonry building types in Lisbon
    Ana Simões
    Jelena Milošević
    Helena Meireles
    Rita Bento
    Serena Cattari
    Sergio Lagomarsino
    Bulletin of Earthquake Engineering, 2015, 13 : 3083 - 3105
  • [23] Comparative fragility methods for seismic assessment of masonry buildings located in Muccia (Italy)
    Chieffo, Nicola
    Clementi, Francesco
    Formisano, Antonio
    Lenci, Stefano
    JOURNAL OF BUILDING ENGINEERING, 2019, 25
  • [24] Masonry buildings subjected to settlements: Half-scale testing, detailed measurements, and insights into behaviour
    Dalgic, Korhan Deniz
    Gulen, Burcu
    Liu, Yiyan
    Acikgoz, Sinan
    Burd, Harvey
    Marasli, Muhammed
    Ilki, Alper
    ENGINEERING STRUCTURES, 2023, 278
  • [25] Development of seismic fragility curves for hospital buildings using empirical damage observations
    Shooraki, Mohammad Kargar
    Bastami, Morteza
    Abbasnejadfard, Morteza
    Motamed, Hooman
    INTERNATIONAL JOURNAL OF DISASTER RISK REDUCTION, 2024, 108
  • [26] Analysis of a scaled stone masonry facade subjected to differential settlements
    Giardina, G.
    Marini, A.
    Riva, P.
    Giuriani, E.
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2020, 14 (10) : 1502 - 1516
  • [27] A simplified non-linear modelling strategy to generate fragility curves for old masonry buildings
    Stocchi, Alessandro
    Giry, Cedric
    Capdevielle, Sophie
    Zentner, Irmela
    Nayman, Emmanuelle
    Ragueneau, Frederic
    COMPUTERS & STRUCTURES, 2021, 254
  • [28] Fragility curves for reinforced concrete frames with retrofitted masonry infills
    Blasi, Gianni
    Perrone, Daniele
    Aiello, Maria Antonietta
    JOURNAL OF BUILDING ENGINEERING, 2023, 75
  • [29] Seismic fragility modelling of unreinforced masonry buildings in Campania region
    Buonocunto, Valentina
    Acconcia, Elia
    Parisi, Fulvio
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 67 - 74
  • [30] Analytical fragility curves proposal for Tuscan masonry building typologies
    Lazzerini, Giacomo
    Menichini, Giovanni
    Del Monte, Emanuele
    Orlando, Maurizio
    Vignoli, Andrea
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 163 - 170