Optimizing PCM Integrated Wall and Roof for Energy Saving in Building under Various Climatic Conditions of Mediterranean Region

被引:20
|
作者
Dardouri, Sana [1 ]
Tuncbilek, Ekrem [2 ,3 ]
Khaldi, Othmen [4 ]
Arici, Muslum [2 ,3 ]
Sghaier, Jalila [1 ]
机构
[1] Univ Monastir, Natl Engn Sch Monastir, Res Lab Thermal & Thermodynam Ind Proc LRTTPI, Monastir 5000, Tunisia
[2] Kocaeli Univ, Engn Fac, Mech Engn Dept, Umuttepe Campus, TR-41001 Kocaeli, Turkiye
[3] Kocaeli Univ, Int Joint Lab Low Carbon & New Energy Nexus Res &, TR-41001 Kocaeli, Turkiye
[4] Univ Tunis El Manar, Lab Mat Org & Properties LMOP LR99ES17, Tunis 2092, Tunisia
关键词
phase change materials; building performance; climatic condition; PCM melting temperature; CO2; reduction; PCM double layer; THERMAL STORAGE; OPTIMIZATION; PERFORMANCE; SYSTEM; CLASSIFICATION; MANAGEMENT; EFFICIENCY;
D O I
10.3390/buildings13030806
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy conservation in buildings has been the focus of many studies since nearly one-third of global energy consumption is due to buildings. Phase change material (PCM) technology promises to be an attractive solution for energy saving in buildings since it is a passive and effective technology, as demonstrated in the literature. Therefore, this study focuses on the energy-saving performance of PCM-integrated buildings located in a Mediterranean climate to reveal their energy-saving potential. PCM is integrated both in external or internal south walls and roofs of buildings under four different climatic conditions. EnergyPlus, which is a well-known building simulation software, is adopted for building thermal analyses. The effects of melting temperature, location of PCM layer in the wall, thickness of PCM layer, type of envelope (wall or roof), and PCM double-layer system in the wall are investigated. The corresponding energy savings and CO2 emission reductions are obtained for the considered cases. The results showed that up to 41.6% reduction in energy demand can be obtained depending on the PCM application. Besides, PCM with a low melting temperature (21 degrees C) favored heating energy savings, while PCM with a high melting temperature (29 degrees C) favored cooling energy savings. Moreover, the double-layer PCM system provided higher energy savings than the single-layer PCM system, especially in warm and arid regions (Sousse and Tozeur).
引用
收藏
页数:19
相关论文
共 48 条
  • [31] Development and hygrothermal performance analysis of a novel eco-friendly insulating wall under various climatic conditions
    Sawadogo, M.
    Benmahiddine, F.
    Godin, A.
    Duquesne, M.
    Belarbi, R.
    Hamami, A.
    BUILDING AND ENVIRONMENT, 2023, 245
  • [32] Thermal and optical investigations of various transparent wall configurations and building integrated photovoltaic for energy savings in buildings
    Marei, Youssef A.
    Emam, Mohamed
    Ahmed, Mohamed E. A. E.
    Attia, Ahmed A. A.
    Abdelrahman, M. A.
    ENERGY CONVERSION AND MANAGEMENT, 2024, 299
  • [33] Parametric study and sensitivity analysis on thermoelectric energy generation of building integrated photovoltaic facades in various climatic zones of China
    Fu, Yijun
    Xu, Wei
    Wang, Zhichao
    Zhang, Shicong
    Chen, Xi
    Wang, Boyuan
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [34] Are ICFs suitable building envelope solutions for Mediterranean climatic conditions? A critical analysis concerning thermal properties and cooling energy performances
    Carpino, Cristina
    Bruno, Roberto
    Bevilacqua, Piero
    Arcuri, Natale
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 480 - 487
  • [35] Adaptive building roof by coupling thermochromic material and phase change material: Energy performance under different climate conditions
    Hu, Jianying
    Yu, Xiong
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 262
  • [36] Artificial neural network for predicting annual output energy of building-integrated photovoltaics based on the 2-terminal perovskite/silicon tandem cells under realistic conditions
    Nguyen, Dong C.
    Ishikawa, Yasuaki
    ENERGY REPORTS, 2022, 8 : 10819 - 10832
  • [37] Experimental investigation of building heating and ventilation by using Trombe wall coupled with renewable energy system under semi-arid climate conditions
    Elghamry, Rania
    Hassan, Hamdy
    SOLAR ENERGY, 2020, 201 (201) : 63 - 74
  • [38] The effects of substrate depth and irrigation regime, on seeded Sedum species grown on urban extensive green roof systems under semi-arid Mediterranean climatic conditions
    Nektarios, Panayiotis A.
    Kokkinou, Iro
    Ntoulas, Nikolaos
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2021, 279
  • [39] Numerical study on the effect of optimizing the Trombe wall structure with built-in fins on improving building energy efficiency in severe cold region
    Wang, Ye
    Chen, Xueqin
    Qi, Xiaobing
    Zhou, Jie
    RENEWABLE ENERGY, 2024, 222
  • [40] Techno-Econo-Enviro Energy Analysis, Ranking and Optimization of Various Building-Integrated Photovoltaic (BIPV) Types in Different Climatic Regions of Iran
    Jahangiri, Mehdi
    Yousefi, Yasaman
    Pishkar, Iman
    Dehshiri, Seyyed Jalaladdin Hosseini
    Dehshiri, Seyyed Shahabaddin Hosseini
    Vanani, Seyyed Mohammad Fatemi
    ENERGIES, 2023, 16 (01)