Optimizing PCM Integrated Wall and Roof for Energy Saving in Building under Various Climatic Conditions of Mediterranean Region

被引:20
|
作者
Dardouri, Sana [1 ]
Tuncbilek, Ekrem [2 ,3 ]
Khaldi, Othmen [4 ]
Arici, Muslum [2 ,3 ]
Sghaier, Jalila [1 ]
机构
[1] Univ Monastir, Natl Engn Sch Monastir, Res Lab Thermal & Thermodynam Ind Proc LRTTPI, Monastir 5000, Tunisia
[2] Kocaeli Univ, Engn Fac, Mech Engn Dept, Umuttepe Campus, TR-41001 Kocaeli, Turkiye
[3] Kocaeli Univ, Int Joint Lab Low Carbon & New Energy Nexus Res &, TR-41001 Kocaeli, Turkiye
[4] Univ Tunis El Manar, Lab Mat Org & Properties LMOP LR99ES17, Tunis 2092, Tunisia
关键词
phase change materials; building performance; climatic condition; PCM melting temperature; CO2; reduction; PCM double layer; THERMAL STORAGE; OPTIMIZATION; PERFORMANCE; SYSTEM; CLASSIFICATION; MANAGEMENT; EFFICIENCY;
D O I
10.3390/buildings13030806
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy conservation in buildings has been the focus of many studies since nearly one-third of global energy consumption is due to buildings. Phase change material (PCM) technology promises to be an attractive solution for energy saving in buildings since it is a passive and effective technology, as demonstrated in the literature. Therefore, this study focuses on the energy-saving performance of PCM-integrated buildings located in a Mediterranean climate to reveal their energy-saving potential. PCM is integrated both in external or internal south walls and roofs of buildings under four different climatic conditions. EnergyPlus, which is a well-known building simulation software, is adopted for building thermal analyses. The effects of melting temperature, location of PCM layer in the wall, thickness of PCM layer, type of envelope (wall or roof), and PCM double-layer system in the wall are investigated. The corresponding energy savings and CO2 emission reductions are obtained for the considered cases. The results showed that up to 41.6% reduction in energy demand can be obtained depending on the PCM application. Besides, PCM with a low melting temperature (21 degrees C) favored heating energy savings, while PCM with a high melting temperature (29 degrees C) favored cooling energy savings. Moreover, the double-layer PCM system provided higher energy savings than the single-layer PCM system, especially in warm and arid regions (Sousse and Tozeur).
引用
收藏
页数:19
相关论文
共 48 条
  • [21] Electrical and thermal performance of SPVT air collector integrated to south roof of a building for cold climatic conditions
    Gupta, Neha
    Tiwari, G. N.
    SOLAR ENERGY, 2024, 275
  • [22] Energy analysis of the building integrated with a double PCM wallboard system in various climate regions of Iran
    Amirhossein Refahi
    Abolfazl Rostami
    Mohammad Amani
    Journal of Thermal Analysis and Calorimetry, 2023, 148 : 7981 - 7993
  • [23] Energy consumption analysis of a residential building with phase change materials under various cooling and heating conditions
    Kim, Taeyeon
    Ahn, Sangmin
    Leigh, Seung-Bok
    INDOOR AND BUILT ENVIRONMENT, 2014, 23 (05) : 730 - 741
  • [24] Optimization of roof solar reflectance under different climate conditions, occupancy, building configuration and energy systems
    Piselli, Cristina
    Saffari, Mohammad
    de Gracia, Alvaro
    Pisello, Anna Laura
    Cotana, Franco
    Cabeza, Luisa F.
    ENERGY AND BUILDINGS, 2017, 151 : 81 - 97
  • [25] An innovative PCM system for thermal comfort improvement and energy demand reduction in building under different climate conditions
    Ahangari, Mohamad
    Maerefat, Mehdi
    SUSTAINABLE CITIES AND SOCIETY, 2019, 44 : 120 - 129
  • [26] Energy and indoor thermal performance analysis of a glazed facade high-rise building under various Nordic climatic conditions
    Bhattacharjee, Shimantika
    Lidelow, Sofia
    Shadram, Farshid
    ENERGY REPORTS, 2023, 10 : 3039 - 3053
  • [27] Energy and cost efficiency of phase change materials integrated in building envelopes under Tunisia Mediterranean climate
    Saafi, Khawla
    Daouas, Naouel
    ENERGY, 2019, 187
  • [28] Energy-saving of building envelope using passive PCM technique: A case study of Kuwait City climate conditions
    Al-Rashed, Abdullah A. A. A.
    Alnaqi, Abdulwahab A.
    Alsarraf, Jalal
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 46
  • [29] Colored filter's impact on the solar cells' electric output under real climatic conditions for application in building integrated photovoltaics
    Ben Amara, Mahmoud
    Balghouthi, Moncef
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [30] Impact of glazing type, window-to-wall ratio, and orientation on building energy savings quality: A parametric analysis in Algerian climatic conditions
    Cherier, Mohamed Kamal
    Hamdani, Maamar
    Kamel, Ehsan
    Guermoui, Mawloud
    Bekkouche, Sidi Mohammed El Amine
    Al-Saadi, Saleh
    Djeffal, Rachid
    Bashir, Maaz Osman
    Elshekh, Ali. E. A.
    Drozdova, Lubomira
    Kanan, Mohammad
    Flah, Aymen
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61