Evaluating the Thermal Performance and Environmental Impact of Agricultural Greenhouses Using Earth-to-Air Heat Exchanger: An Experimental Study

被引:7
|
作者
Hamdane, Samia [1 ,2 ]
Pires, Luis Carlos Carvalho [2 ,3 ]
Silva, Pedro Dinho [2 ,3 ]
Gaspar, Pedro Dinis [2 ,3 ]
机构
[1] Mohamed Khider Univ, Lab Mech Engn LGM, BP 145 RP, Biskra 07000, Algeria
[2] Univ Beira Interior, Dept Electromech Engn, Rua Marques Avila & Bolama, P-6201001 Covilha, Portugal
[3] C MAST Ctr Mech & Aerosp Sci & Technol, P-6201001 Covilha, Portugal
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 02期
关键词
greenhouse; earth-to-air heat exchanger; CO2; emissions; energy consumption; environmental impact; sustainability; REGION; SYSTEM;
D O I
10.3390/app13021119
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The thermal performance and environmental impact of agricultural greenhouses (GH) connected to earth-to-air heat exchanger (EAHE) systems depend on the ambient temperature, soil temperature, EAHE system, and greenhouse specifications. The impact of an EAHE system on the temperature and humidity of a GH microclimate, as well as its effects on CO2 emissions and heating energy consumption, are determined experimentally. Two scaled-down models of agricultural GHs (2 x 1.4 x 1.4 m(3)) were developed. Each GH was equipped with a heater. A spiral EAHE system was integrated into only one of the GHs. The temperature differences in the microclimate range from 3.5 degrees C to 7.5 degrees C, with the microclimates of GH + EAHE and GH being quite similar. In summary, the EAHE system helped to reduce the hourly energy consumption of the heating system by more than 40%. It also reduced emissions to the environment by more than 100 g (CO2)/hour. The EAHE coefficient of performance (COP) for the cooling mode has a higher average value than that for the heating mode. The closed-loop performed better in cooling mode, while the open-loop performed better in heating mode. When the difference between the set temperature in the heater and the air outlet temperature of the EAHE system is smaller, the heater performs better in reducing energy consumption and CO2 emissions of the heater. The COPheating range is between 0 and 3.4 and the COPcooling range is between 0.5 and 7.3. The energy consumption ranges between 0 and 1.41 kWh and the CO2 emissions are between 0 and 359.55 g. Thus, using EAHE in agricultural greenhouses improves thermal performance and reduces environmental impact, providing an overall benefit in terms of energy consumption and environmental sustainability.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Experimental study of the efficiency of earth-to-air heat exchangers: Effect of the presence of external fans
    Ahmad, Hijaz
    Sakhri, Nasreddine
    Menni, Younes
    Omri, Mohamed
    Ameur, Houari
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [42] Impact of the environmental conditions on the efficiency of earth-to-air heat exchangers under various configurations
    N. Sakhri
    Y. Menni
    H. Ameur
    International Journal of Environmental Science and Technology, 2022, 19 : 223 - 236
  • [43] Impact of the environmental conditions on the efficiency of earth-to-air heat exchangers under various configurations
    Sakhri, N.
    Menni, Y.
    Ameur, H.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2022, 19 (01) : 223 - 236
  • [44] Numerical Modeling and Experimental Studies of the Operational Parameters of the Earth-To-Air Heat Exchanger of the Geothermal Ventilation System
    Basok, Boris
    Bozhko, Ihor
    Novitska, Maryna
    Nedbailo, Aleksandr
    Tkachenko, Myroslav
    ROCZNIK OCHRONA SRODOWISKA, 2021, 23 : 42 - 64
  • [45] Numerical and experimental analysis of the energy performance of an air-source heat pump (ASHP) coupled with a horizontal earth-to-air heat exchanger (EAHX) in different climates
    Congedo, Paolo Maria
    Baglivo, Cristina
    Bonuso, Sara
    D'Agostino, Delia
    GEOTHERMICS, 2020, 87
  • [46] Numerical simulation of diurnal and annual performance of coupled solar chimney with earth-to-air heat exchanger system
    Long, Tianhe
    Zhao, Ningjing
    Li, Wuyan
    Wei, Shen
    Li, Yongcai
    Lu, Jun
    Huang, Sheng
    Qiao, Zhenyong
    APPLIED THERMAL ENGINEERING, 2022, 214
  • [47] A Numerical Investigation of Thermal Performance of Earth-Air Heat Exchanger
    Tasdelen, F.
    Dagtekin, I.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (02) : 1151 - 1163
  • [48] Thermal Analysis of a Generic Earth-to-Air Heat Exchanger Coupled with a Room during the Summer Season in a Desert Climate
    Maytorena, V. M.
    Hinojosa, J. F.
    JOURNAL OF ENERGY ENGINEERING, 2022, 148 (02)
  • [49] Thermal design of Earth-to-air heat exchanger. Part II a new transient semi-analytical model and experimental validation for estimating air temperature
    Mehdid, Charaf-Eddine
    Benchabane, Adel
    Rouag, Amar
    Moummi, Noureddine
    Melhegueg, Mohammed-Amin
    Moummi, Abdelhafid
    Benabdi, Mohamed-Larbi
    Brima, Abdelhafid
    JOURNAL OF CLEANER PRODUCTION, 2018, 198 : 1536 - 1544
  • [50] Parametric study and optimization of a solar chimney passive ventilation system coupled with an earth-to-air heat exchanger
    Serageldin, Ahmed A.
    Abdelrahman, Ali K.
    Ookawara, Shinichi
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2018, 30 : 263 - 278