Advancement in pleura effusion diagnosis: a systematic review and meta-analysis of point-of-care ultrasound versus radiographic thoracic imaging

被引:7
作者
Zaki, Hany A. [1 ]
Albaroudi, Bilal [1 ]
Shaban, Eman E. [2 ]
Shaban, Ahmed [3 ]
Elgassim, Mohamed [1 ]
Almarri, Nood Dhafi [1 ]
Basharat, Kaleem [1 ]
Azad, Aftab Mohammad [1 ,4 ,5 ]
机构
[1] Hamad Med Corp, Dept Emergency Med, Doha, Qatar
[2] Al Jufairi Diag & Treatment, Dept Cardiol, MOH, Doha, Qatar
[3] Mansoura Gen Hosp, Dept Internal Med, Mansoura, Egypt
[4] Hamad Med Corp, Coll Med QU, Doha, Qatar
[5] Weill Cornell Med Coll, Doha, Qatar
关键词
Pleural effusion; Diagnostic imaging; Emergency medicine; Meta-analysis; Point-of-care systems; Ultrasound; Chest X-ray; Sensitivity; Specificity; Systematic review; ACCURACY; SONOGRAPHY; ULTRASONOGRAPHY; PERFORMANCE; PULMONARY; VOLUME; FLUID; ICU;
D O I
10.1186/s13089-023-00356-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundPleural effusion is a fluid buildup in the pleural space that mostly result from congestive heart failure, bacterial pneumonia, malignancy, and pulmonary embolism. The diagnosis of this condition can be challenging as it presents symptoms that may overlap with other conditions; therefore, imaging diagnostic tools such as chest x-ray/radiograph (CXR), point-of-care ultrasound (POCUS), and computed tomography (CT) have been employed to make an accurate diagnosis. Although POCUS has high diagnostic accuracy, it is yet to be considered a first-line diagnostic tool as most physicians use radiography. Therefore, the current meta-analysis was designed to compare POCUS to chest radiography.Methodsn extended search for studies related to our topic was done on five electronic databases, including PubMed, Medline, Embase, Scopus, and Google Scholar. A quality assessment using the Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) was performed on all eligible articles obtained from the databases. Moreover, the diagnostic accuracy of POCUS and CXR was performed using STATA 16 software.ResultsOur search yielded 1642 articles, of which only 18 were eligible for inclusion and analysis. The pooled analysis showed that POCUS had a higher diagnostic accuracy compared to CXR (94.54% (95% CI 91.74-97.34) vs. 67.68% (95% CI 58.29-77.08) and 97.88% (95% CI 95.77-99.99) vs. 85.30% (95% CI 80.06-90.54) sensitivity and specificity, respectively). A subgroup analysis based on the position of patients during examinations showed that POCUS carried out in supine and upright positions had higher specificity than other POCUS positions (99%). In comparison, lateral decubitus CXR had higher sensitivity (96%) and specificity (99%) than the other CXR positions. Further subgroup analyses demonstrated that CXR had higher specificity in studies that included more than 100 patients (92.74% (95% CI 85.41-100). Moreover, CXR tends to have a higher diagnostic accuracy when other CXR positions are used as reference tests (93.38% (95% CI 86.30-100) and 98.51% (95% CI 94.65-100) sensitivity and specificity, respectively).ConclusionPOCUS as an imaging modality has higher diagnostic accuracy than CXR in detecting pleural effusion. Moreover, the accuracy is still high even when performed by physicians with less POCUS training. Therefore, we suggest it is considered a first-line imaging tool for diagnosing pleural effusion at the patients' bedside.
引用
收藏
页数:16
相关论文
共 46 条
  • [1] Ahmed AS., 2022, Zagazig Univ Med J, V28, P1377, DOI [10.21608/zumj.2022.164100.2647, DOI 10.21608/ZUMJ.2022.164100.2647]
  • [2] Ultrasound estimation of volume of pleural fluid in mechanically ventilated patients
    Balik, M
    Plasil, P
    Waldauf, P
    Pazout, J
    Fric, M
    Otahal, M
    Pachl, J
    [J]. INTENSIVE CARE MEDICINE, 2006, 32 (02) : 318 - 321
  • [3] Mitoxantrone pleurodesis to palliate malignant pleural effusion secondary to ovarian cancer
    Barbetakis N.
    Vassiliadis M.
    Kaplanis K.
    Valeri R.
    Tsilikas C.
    [J]. BMC Palliative Care, 3 (1)
  • [4] Pleural effusions
    Beers, Sara L.
    Abramo, Thomas J.
    [J]. PEDIATRIC EMERGENCY CARE, 2007, 23 (05) : 330 - 334
  • [5] Tuberculous Pleural Effusion: Clinical Characteristics of 320 Patients
    Bielsa, Silvia
    Acosta, Cristina
    Pardina, Marina
    Civit, Carmen
    Porcel, Jose M.
    [J]. ARCHIVOS DE BRONCONEUMOLOGIA, 2019, 55 (01): : 17 - 22
  • [6] Boka K, 2022, Pleural Effusion: Background, Anatomy, Etiology
  • [7] The efficacy of chest radiographs in detecting parapneumonic effusions
    Brixey, Anupama G.
    Luo, Yifeng
    Skouras, Vasileios
    Awdankiewicz, Anna
    Light, Richard W.
    [J]. RESPIROLOGY, 2011, 16 (06) : 1000 - 1004
  • [8] Diagnostic Performance of 6-Point Lung Ultrasound in ICU Patients: A Comparison with Chest X-Ray and CT Thorax
    Danish, Mohammad
    Agarwal, Aarti
    Goyal, Puneet
    Gupta, Devendra
    Lal, Hira
    Prasad, Raghunandan
    Dhiraaj, Sanjay
    Agarwal, Anil
    Mishra, Prabhaker
    [J]. TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2019, 47 (04) : 307 - 319
  • [9] Accuracy of pleural puncture sites -: A prospective comparison of clinical examination with ultrasound
    Diacon, AH
    Brutsche, MH
    Solèr, M
    [J]. CHEST, 2003, 123 (02) : 436 - 441
  • [10] Elmahalawy II, 2017, EGYPT J CHEST DIS TU, V66, P261, DOI 10.1016/j.ejcdt.2016.10.005