Optimization of MLP neural network for modeling effects of electric fields on bubble growth in pool boiling

被引:0
|
作者
Ghazvini, Mahyar [1 ]
Varedi-Koulaei, Seyyed Mojtaba [2 ]
Ahmadi, Mohammad Hossein [2 ]
Kim, Myeongsub [1 ]
机构
[1] Florida Atlantic Univ, Dept Ocean & Mech Engn, 777 Glades Rd, Boca Raton, FL 33431 USA
[2] Shahrood Univ Technol, Fac Mech & Mechatron Engn, Shahrood, Iran
基金
美国国家科学基金会;
关键词
HEAT-TRANSFER; DEPARTURE DIAMETER; SINGLE BUBBLE; EHD BEHAVIOR; PURE FLUIDS; ALGORITHM; ENHANCEMENT; FREQUENCY; MIXTURES; WATER;
D O I
10.1007/s00231-023-03434-z
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a multilayer perceptron (MLP)-type artificial neural network model with a back-propagation training algorithm is utilized to model the bubble growth and bubble dynamics parameters in nucleate boiling with a non-uniform electric field. The influences of the electric field on different parameters that describe bubble's behaviors including bubble waiting time, bubble departure frequency, bubble growth time, and bubble departure diameter are considered. This study models single bubble dynamic behaviors of R113 created on a heater in an inconsistent electric field by utilizing a MLP neural network optimized by four different swarm-based optimization algorithms, namely: Salp Swarm Algorithm (SSA), Grey Wolf Optimizer (GWO), Artificial Bee Colony (ABC) algorithm, and Particle Swarm Optimization (PSO). For evaluating the model effectiveness, the MSE value (Mean-Square Error) of the artificial neural network model with various optimization algorithms is measured and compared. The results suggest that the optimal networks in the two-hidden layer and three-hidden layer models for the bubble departure diameter improve MSE by 33.85% and 35.27%, respectively, when compared with the best response in the one-hidden layer model. Additionally, for bubble growth time, the networks with two hidden layers and three hidden layers have the 44.51% and 45.85% reduction in error, when compared with the network with one hidden layer, respectively. For the departure frequency, the error reduction in the two-layer and three-layer networks is 46.85% and 62.32%, respectively. For bubble waiting time, the best networks in the two hidden-layer and three hidden-layer models improve MSE by 52.44% and 62.27% compared with the best 1HL model response, respectively. Also, the two algorithms of SSA and GWO are able to compete well (comparable MSE) with the PSO and ABC algorithms.
引用
收藏
页码:329 / 361
页数:33
相关论文
共 50 条
  • [21] Experimental Investigation and Modeling of Bubble Departure Frequency for Pool-Boiling Heat Transfer
    Hamzekhani, Samane
    Shahraki, Farhad
    Mohebbi-Kalhori, Davood
    Fardinpour, Mohammad Reza
    CHEMICAL ENGINEERING & TECHNOLOGY, 2022, 45 (11) : 2049 - 2060
  • [22] Wall Superheat Effect on Single Bubble Growth During Nucleate Boiling at Saturated Pool
    Kim, Jeongbae
    Lee, Han Choon
    Kim, Moo Hwan
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2005, 29 (05) : 633 - 642
  • [23] The effect of surfactants on bubble growth, wall thermal patterns and heat transfer in pool boiling
    Hetsroni, G
    Zakin, JL
    Lin, Z
    Mosyak, A
    Pancallo, EA
    Rozenblit, R
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (02) : 485 - 497
  • [24] A kinetics-based universal model for single bubble growth and departure in nucleate pool boiling
    Haustein, Herman D.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2018, 105 : 15 - 31
  • [25] Weak electric fields detectability in a noisy neural network
    Zhao, Jia
    Deng, Bin
    Qin, Yingmei
    Men, Cong
    Wang, Jiang
    Wei, Xile
    Sun, Jianbing
    COGNITIVE NEURODYNAMICS, 2017, 11 (01) : 81 - 90
  • [26] Experimental study of the effects of horizontal and vertical roughnesses of heater surface on bubble dynamic and heat transfer coefficient in pool boiling
    Khooshehchin, Mohsen
    Fathi, Sohrab
    Mohammadidoust, Akbar
    Salimi, Farhad
    Ovaysi, Saeed
    HEAT AND MASS TRANSFER, 2022, 58 (08) : 1319 - 1338
  • [27] Investigating effects of heating orientations on nucleate boiling heat transfer, bubble dynamics, and wall heat flux partition boiling model for pool boiling
    Chuang, T. J.
    Chang, Y. H.
    Ferng, Y. M.
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [28] Evaluation of the microlayer contribution to bubble growth in horizontal pool boiling with a mechanistic model that considers dynamic contact angle and base expansion
    Ding, Wei
    Krepper, Eckhard
    Hampel, Uwe
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2018, 72 : 274 - 287
  • [29] Effects of contact angle hysteresis on bubble dynamics and heat transfer characteristics in saturated pool boiling
    Wang, Haoyuan
    Lou, Qin
    Liu, Gaojie
    Li, Ling
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 178
  • [30] Water pool boiling in metal foams: From experimental results to a generalized model based on artificial neural network
    Calati, M.
    Righetti, G.
    Doretti, L.
    Zilio, C.
    Longo, G. A.
    Hooman, K.
    Mancin, S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 176