Optimization of phase contrast imaging with a nano-focus x-ray tube

被引:3
|
作者
Dierks, Hanna [1 ]
Dreier, Till [2 ,3 ]
Krueger, Robin [2 ,4 ]
Bech, Martin [2 ]
Wallentin, Jesper [1 ]
机构
[1] Lund Univ, Dept Phys, Synchrotron Radiat Res & NanoLund, POB 118, S-22100 Lund, Sweden
[2] Lund Univ, Dept Med Radiat Phys, Clin Sci Lund, S-22185 Lund, Sweden
[3] Excillum AB, Jan Stenbecks Torg 17, S-16440 Kista, Sweden
[4] Tech Univ Berlin, Inst Opt & Atomare Phys, Hardenbergstr 36, D-10623 Berlin, Germany
关键词
TOMOGRAPHY;
D O I
10.1364/AO.491669
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Propagation-based phase contrast imaging with a laboratory x-ray source is a valuable tool for studying samples that show only low absorption contrast, either because of low density, elemental composition, or small feature size. If a propagation distance between sample and detector is introduced and the illumination is sufficiently coherent, the phase shift in the sample will cause additional contrast around interfaces, known as edge enhancement fringes. The strength of this effect depends not only on sample parameters and energy but also on the experimental geometry, which can be optimized accordingly. Recently, x-ray lab sources using transmission targets have become available, which provide very small source sizes in the few hundred nanometer range. This allows the use of a high magnification geometry with a very short source-sample distance, while still achieving sufficient spatial coherence at the sample position. Moreover, the high geometrical magnification makes it possible to use detectors with a larger pixel size without reducing the image resolution. Here, we explore the influence of magnification on the edge enhancement fringes in such a geometry. We find experimentally and theoretically that the fringes become maximal at a magnification that is independent of the total source-detector distance. This optimal magnification only depends on the source size, the steepness of the sample feature, and the detector resolution. A stronger influence of the sample feature on the optimal magnification compared to low-magnification geometries is observed.
引用
收藏
页码:5502 / 5507
页数:6
相关论文
共 50 条
  • [41] Comparison of two x-ray phase-contrast imaging methods with a microfocus source
    Zhou, T.
    Lundstrom, U.
    Thuering, T.
    Rutishauser, S.
    Larsson, D. H.
    Stampanoni, M.
    David, C.
    Hertz, H. M.
    Burvall, A.
    OPTICS EXPRESS, 2013, 21 (25): : 30183 - 30195
  • [42] Restoration of X-ray phase-contrast imaging based on generative adversarial networks
    Zeng, Jiacheng
    Huang, Jianheng
    Zeng, Jiancheng
    Li, Jiaqi
    Lei, Yaohu
    Liu, Xin
    Ye, Huacong
    Du, Yang
    Zhang, Chenggong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [43] Hard X-ray quantitative non-interferometric phase-contrast imaging
    Gureyev, TE
    Raven, C
    Snigirev, A
    Snigireva, I
    Wilkins, SW
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 356 - 364
  • [44] Spectral X-ray phase contrast imaging with a CdTe photon-counting detector
    Navarrete, Carlos
    Procz, Simon
    Schuetz, Michael Kilian
    Roque, Gerardo
    Fey, Julian
    Avila, Carlos
    Olivo, Alessandro
    Fiederle, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 971 (971):
  • [45] On the evolution and relative merits of hard X-ray phase-contrast imaging methods
    Wilkins, S. W.
    Nesterets, Ya. I.
    Gureyev, T. E.
    Mayo, S. C.
    Pogany, A.
    Stevenson, A. W.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 372 (2010):
  • [46] Proposed Imaging of the Ultrafast Electronic Motion in Samples using X-Ray Phase Contrast
    Dixit, Gopal
    Slowik, Jan Malte
    Santra, Robin
    PHYSICAL REVIEW LETTERS, 2013, 110 (13)
  • [47] Absorption and Phase Contrast X-Ray Imaging in Paleontology Using Laboratory and Synchrotron Sources
    Bidola, Pidassa
    Stockmar, Marco
    Achterhold, Klaus
    Pfeiffer, Franz
    Pacheco, Mirian L. A. F.
    Soriano, Carmen
    Beckmann, Felix
    Herzen, Julia
    MICROSCOPY AND MICROANALYSIS, 2015, 21 (05) : 1288 - 1295
  • [48] Phase contrast x-ray velocimetry of small animal lungs: optimising imaging rates
    Murrie, R. P.
    Paganin, D. M.
    Fouras, A.
    Morgan, K. S.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (01): : 79 - 92
  • [49] Simulation and measurement of grating-based X-ray phase-contrast imaging
    Bartl, P.
    Bayer, F.
    Durst, J.
    Haas, W.
    Michel, T.
    Pelzer, G.
    Ritter, A.
    Weber, T.
    Anton, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S269 - S272
  • [50] Grating-based X-ray phase-contrast imaging at PETRA III
    Hipp, A.
    Beckmann, F.
    Lytaev, P.
    Greving, I.
    Lottermoser, L.
    Dose, T.
    Kirchhof, R.
    Burmester, H.
    Schreyer, A.
    Herzen, J.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212