Optimization of phase contrast imaging with a nano-focus x-ray tube

被引:3
|
作者
Dierks, Hanna [1 ]
Dreier, Till [2 ,3 ]
Krueger, Robin [2 ,4 ]
Bech, Martin [2 ]
Wallentin, Jesper [1 ]
机构
[1] Lund Univ, Dept Phys, Synchrotron Radiat Res & NanoLund, POB 118, S-22100 Lund, Sweden
[2] Lund Univ, Dept Med Radiat Phys, Clin Sci Lund, S-22185 Lund, Sweden
[3] Excillum AB, Jan Stenbecks Torg 17, S-16440 Kista, Sweden
[4] Tech Univ Berlin, Inst Opt & Atomare Phys, Hardenbergstr 36, D-10623 Berlin, Germany
关键词
TOMOGRAPHY;
D O I
10.1364/AO.491669
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Propagation-based phase contrast imaging with a laboratory x-ray source is a valuable tool for studying samples that show only low absorption contrast, either because of low density, elemental composition, or small feature size. If a propagation distance between sample and detector is introduced and the illumination is sufficiently coherent, the phase shift in the sample will cause additional contrast around interfaces, known as edge enhancement fringes. The strength of this effect depends not only on sample parameters and energy but also on the experimental geometry, which can be optimized accordingly. Recently, x-ray lab sources using transmission targets have become available, which provide very small source sizes in the few hundred nanometer range. This allows the use of a high magnification geometry with a very short source-sample distance, while still achieving sufficient spatial coherence at the sample position. Moreover, the high geometrical magnification makes it possible to use detectors with a larger pixel size without reducing the image resolution. Here, we explore the influence of magnification on the edge enhancement fringes in such a geometry. We find experimentally and theoretically that the fringes become maximal at a magnification that is independent of the total source-detector distance. This optimal magnification only depends on the source size, the steepness of the sample feature, and the detector resolution. A stronger influence of the sample feature on the optimal magnification compared to low-magnification geometries is observed.
引用
收藏
页码:5502 / 5507
页数:6
相关论文
共 50 条
  • [31] Phase-Contrast Imaging in a Polychromatic X-ray Beam at a Laboratory Source
    Krivonosov, Yu. S.
    Asadchikov, V. E.
    Buzmakov, A. V.
    CRYSTALLOGRAPHY REPORTS, 2020, 65 (04) : 503 - 507
  • [32] Partial coherence theory for x-ray phase contrast imaging technique with gratings
    Zhou, Yu
    Louis, Alfred K.
    Zhou, Tie
    Jiang, Ming
    OPTICS COMMUNICATIONS, 2012, 285 (24) : 4763 - 4774
  • [33] Talbot phase-contrast x-ray imaging for the small joints of the hand
    Stutman, Dan
    Beck, Thomas J.
    Carrino, John A.
    Bingham, Clifton O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17): : 5697 - 5720
  • [34] Development of microperiodic mirrors for hard x-ray phase-contrast imaging
    Stutman, Dan
    Finkenthal, Michael
    Moldovan, Nicolae
    APPLIED OPTICS, 2010, 49 (25) : 4677 - 4686
  • [35] Phase retrieval for non-ideal in-line phase contrast x-ray imaging
    Guo, Baikuan
    Gao, Feng
    Zhao, Huijuan
    Zhang, Limin
    Li, Jiao
    Zhou, Zhongxing
    QUANTITATIVE PHASE IMAGING III, 2017, 10074
  • [36] Phase retrieval method for in-line phase contrast x-ray imaging and denoising by regularization
    Lee, Ping-Chang
    OPTICS EXPRESS, 2015, 23 (08): : 10668 - 10679
  • [37] X-ray phase contrast imaging and noise evaluation using a single phase grating interferometer
    Rizzi, J.
    Mercere, P.
    Idir, M.
    Da Silva, P.
    Vincent, G.
    Primot, Jerome
    OPTICS EXPRESS, 2013, 21 (14): : 17340 - 17351
  • [38] Three-dimensional phase-contrast X-ray microtomography with scanning-imaging X-ray microscope optics
    Takeuchi, Akihisa
    Uesugi, Kentaro
    Suzuki, Yoshio
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 793 - 800
  • [39] Phase-Contrast and Dark-Field Imaging - Advanced Contrast Modalities in X-Ray Radiology
    Pfeiffer, F.
    Bech, M.
    Jensen, T.
    Bunk, O.
    Donath, T.
    David, C.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 262 - 265
  • [40] Advantages of intermediate X-ray energies in Zernike phase contrast X-ray microscopy
    Wang, Zhili
    Gao, Kun
    Chen, Jian
    Hong, Youli
    Ge, Xin
    Wang, Dajiang
    Pan, Zhiyun
    Zhu, Peiping
    Yun, Wenbing
    Jacobsen, Chris
    Wu, Ziyu
    BIOTECHNOLOGY ADVANCES, 2013, 31 (03) : 387 - 392