Optimization of phase contrast imaging with a nano-focus x-ray tube

被引:3
|
作者
Dierks, Hanna [1 ]
Dreier, Till [2 ,3 ]
Krueger, Robin [2 ,4 ]
Bech, Martin [2 ]
Wallentin, Jesper [1 ]
机构
[1] Lund Univ, Dept Phys, Synchrotron Radiat Res & NanoLund, POB 118, S-22100 Lund, Sweden
[2] Lund Univ, Dept Med Radiat Phys, Clin Sci Lund, S-22185 Lund, Sweden
[3] Excillum AB, Jan Stenbecks Torg 17, S-16440 Kista, Sweden
[4] Tech Univ Berlin, Inst Opt & Atomare Phys, Hardenbergstr 36, D-10623 Berlin, Germany
关键词
TOMOGRAPHY;
D O I
10.1364/AO.491669
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Propagation-based phase contrast imaging with a laboratory x-ray source is a valuable tool for studying samples that show only low absorption contrast, either because of low density, elemental composition, or small feature size. If a propagation distance between sample and detector is introduced and the illumination is sufficiently coherent, the phase shift in the sample will cause additional contrast around interfaces, known as edge enhancement fringes. The strength of this effect depends not only on sample parameters and energy but also on the experimental geometry, which can be optimized accordingly. Recently, x-ray lab sources using transmission targets have become available, which provide very small source sizes in the few hundred nanometer range. This allows the use of a high magnification geometry with a very short source-sample distance, while still achieving sufficient spatial coherence at the sample position. Moreover, the high geometrical magnification makes it possible to use detectors with a larger pixel size without reducing the image resolution. Here, we explore the influence of magnification on the edge enhancement fringes in such a geometry. We find experimentally and theoretically that the fringes become maximal at a magnification that is independent of the total source-detector distance. This optimal magnification only depends on the source size, the steepness of the sample feature, and the detector resolution. A stronger influence of the sample feature on the optimal magnification compared to low-magnification geometries is observed.
引用
收藏
页码:5502 / 5507
页数:6
相关论文
共 50 条
  • [21] A phase retrieval algorithm for polychromatic x-ray in-line phase contrast imaging
    Guo, Xue-jun
    Liu, Xiao-lin
    Gu, Mu
    Ni, Chen
    Liu, Bo
    Huang, Shi-ming
    2012 INTERNATIONAL WORKSHOP ON IMAGE PROCESSING AND OPTICAL ENGINEERING, 2012, 8335
  • [22] Optimization of X-ray Phase Contrast Imaging System toward High-Sensitivity Measurements of Biological Organs
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 255 - 260
  • [23] Contrast transfer function in grating-based x-ray phase-contrast imaging
    Huang, Jianheng
    Du, Yang
    Lin, Danying
    Liu, Xin
    Niu, Hanben
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 747 : 13 - 18
  • [24] Constrained Reconstructions in X-ray Phase Contrast Imaging: Uniqueness, Stability and Algorithms
    Maretzke, Simon
    Hohage, Thorsten
    NANOSCALE PHOTONIC IMAGING, 2020, 134 : 377 - 403
  • [25] A quantitative, non-interferometric X-ray phase contrast imaging technique
    Munro, Peter R. T.
    Rigon, Luigi
    Ignatyev, Konstantin
    Lopez, Frances C. M.
    Dreossi, Diego
    Speller, Robert D.
    Olivo, Alessandro
    OPTICS EXPRESS, 2013, 21 (01): : 647 - 661
  • [26] Regularized Newton methods for x-ray phase contrast and general imaging problems
    Maretzke, Simon
    Bartels, Matthias
    Krenkel, Martin
    Salditt, Tim
    Hohage, Thorsten
    OPTICS EXPRESS, 2016, 24 (06): : 6490 - 6506
  • [27] Grating-based X-ray phase contrast for biomedical imaging applications
    Pfeiffer, Franz
    Herzen, Julia
    Wiliner, Marian
    Chabior, Michael
    Auweter, Sigrid
    Reiser, Maximilian
    Bamberg, Fabian
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (03): : 176 - 185
  • [28] Non-absorption grating approach for X-ray phase contrast imaging
    Du, Yang
    Liu, Xin
    Lei, Yaohu
    Guo, Jinchuan
    Niu, Hanben
    OPTICS EXPRESS, 2011, 19 (23): : 22669 - 22674
  • [29] Noise in x-ray grating-based phase-contrast imaging
    Weber, Thomas
    Bartl, Peter
    Bayer, Florian
    Durst, Juergen
    Haas, Wilhelm
    Michel, Thilo
    Ritter, Andre
    Anton, Gisela
    MEDICAL PHYSICS, 2011, 38 (07) : 4133 - 4140
  • [30] X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials
    Vedantham, Srinivasan
    Karellas, Andrew
    MEDICAL PHYSICS, 2013, 40 (04)