Long-term outcomes following transcatheter aortic valve implantation with the Portico self-expanding valve

被引:3
|
作者
Giordano, Arturo [1 ,2 ]
Mas-Peiro, Silvia [3 ]
Fichtlscherer, Stephan [3 ]
Schaefer, Andreas [4 ]
Beyer, Martin [4 ]
Maisano, Francesco [5 ]
Ascione, Guido [5 ]
Buzzatti, Nicola [5 ]
Teles, Rui [6 ]
Brito, Joao [6 ]
Albuquerque, Francisco [6 ]
Sondergaard, Lars [7 ]
Vanhaverbeke, Maarten [7 ]
Quagliana, Angelo [7 ]
Costa, Giuliano [8 ]
Barbanti, Marco [8 ]
Ferraro, Paolo [1 ,2 ]
Morello, Alberto [1 ,2 ]
Cimmino, Michele [1 ,2 ]
Albanese, Michele [1 ,2 ]
Pepe, Martino [9 ]
Bardi, Luca [1 ,2 ]
Giordano, Salvatore [10 ]
Cittadini, Antonio [11 ]
Corcione, Nicola [1 ,2 ]
Biondi-Zoccai, Giuseppe [12 ,13 ]
机构
[1] Pineta Grande Hosp, Unita Operativa Interventist Cardiovasc, Castel Volturno, Italy
[2] St Lucia Hosp, Unita Operativa Emodinam, San Giuseppe Vesuviano, Italy
[3] Goethe Univ Hosp, Dept Cardiol, Frankfurt, Germany
[4] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Hamburg, Germany
[5] Ist Sci San Raffaele, Dept Cardiac Surg IRCCS, Milan, Italy
[6] Hosp Santa Cruz, Div Cardiol, Carnaxide, Portugal
[7] Rigshospitalet, Heart Ctr, Copenhagen, Denmark
[8] AOU Policlin G Rodolico San Marco, Div Cardiol, Catania, Italy
[9] Univ Bari, Dept Emergency & Organ Transplantat, Div Cardiol, Bari, Italy
[10] Magna Graecia Univ Catanzaro, Dept Med & Surg Sci, Div Cardiol, Catanzaro, Italy
[11] Federico II Univ Naples, Dept Med & Translat Sci, Naples, Italy
[12] Sapienza Univ Rome, Dept Medicosurg Sci & Biotechnol, Latina, Italy
[13] Mediterranea Cardioctr, Naples, Italy
关键词
Aortic stenosis; Portico; Transcatheter aortic valve implantation; Transcatheter aortic valve replacement; NEW-GENERATION DEVICES; REPLACEMENT; STENOSIS; SYSTEM;
D O I
10.1007/s00392-023-02252-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimTranscatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve.MethodsWe retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed.ResultsA total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 & PLUSMN; 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05).ConclusionsPortico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 50 条
  • [21] Pacemaker Requirements following Self-Expanding Transcatheter Aortic Valve Replacement
    Goldsweig, Andrew M.
    Al-Ani, Ahmed
    Almomani, Ahmed
    CARDIOLOGY, 2020, 145 (01) : 35 - 37
  • [22] The next step in transcatheter aortic valve implantation: Transcatheter aortic valve replacement (TAVR) with BASILICA in a patient with a degenerated self-expanding transcatheter heart valve
    Sciborski, Krzysztof
    Telichowski, Artur
    Mak, Marek
    Wysokinska-Kordybach, Agnieszka
    Klausa, Filip
    Cielinski, Grzegorz
    Kustrzycka-Kratochwil, Dorota
    Banasiak, Waldemar
    KARDIOLOGIA POLSKA, 2021, 80 (02) : 233 - 234
  • [23] Long-Term Structural Valve Deterioration of Balloon-Expandable vs. Self-Expanding Transcatheter Aortic Valve Replacement
    Reddy, P. K.
    Zheng, L.
    Khayat, E.
    Snigur, G.
    Sawant, V.
    Cellamare, M.
    Satler, L.
    Ben-Dor, I.
    Rogers, T.
    Sadeghpour, A.
    Waksman, R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (04) : S68 - S68
  • [24] Transcatheter implantation of self-expanding valve for failed stentless aortic root bioprosthesis
    Smolka, Grzegorz
    Ochala, Andrzej
    Pysz, Piotr
    Jasinski, Marek
    KARDIOLOGIA POLSKA, 2013, 71 (06) : 664 - 664
  • [25] Impact of repositioning on brain injury following transcatheter aortic valve replacement with a self-expanding valve
    Fan, Jiaqi
    Chen, Jun
    Zhu, Gangjie
    Xu, Yeming
    Ng, Stella
    Dai, Hanyi
    Zhou, Dao
    Yidilisi, Abuduwufuer
    Qi, Xinrui
    Liu, Xianbao
    Wang, Jian'an
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [26] Thrombocytopenia following transcatheter aortic valve implantation in portico and Evolute recipients
    Totaro, Antonio
    Sacra, Cosimo
    Missiroli, Bindo
    Massetti, Massimo
    Testa, Gianluca
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (SUPPL G)
  • [27] Impact of Repositioning on Brain Injury Following Transcatheter Aortic Valve Replacement With a Self-Expanding Valve
    Chen, Jun
    Liu, Xianbao
    Wang, Jianan
    Fan, Jiaqi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B349 - B349
  • [28] Impact of Transient Conduction Disturbances on Long-term Outcomes Following Transcatheter Aortic Valve Implantation
    Okita, Shogo
    Kitahara, Hideki
    Matsuura, Kaoru
    Matsumiya, Goro
    Kobayashi, Yoshio
    CIRCULATION, 2024, 150
  • [29] Self-Expanding Prostheses for Transcatheter Aortic Valve Replacement
    Kumar, Robert
    Latib, Azeem
    Colombo, Antonio
    Ruiz, Carlos E.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 56 (06) : 596 - 609
  • [30] Long term follow up of percutaneous treatment for degenerated Mitroflow prosthesis with self-expanding transcatheter aortic valve implantation
    Pascual, Isaac
    Alemendarez, Marcel
    Alvarez Velasco, Rut
    Adeba, Antonio
    Hernandez-Vaquero, Daniel
    Lorca, Rebeca
    Diaz, Rocio
    Alperi, Alberto
    Cubero-Gallego, Hector
    Rozado, Jose
    Moris, Cesar
    Avanzas, Pablo
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (15)