Fit and Retention of Cobalt-Chromium Removable Partial Denture Frameworks Fabricated with Selective Laser Melting

被引:4
作者
Rues, Stefan [1 ]
Tasaka, Akinori [2 ]
Fleckenstein, Isabella [1 ]
Yamashita, Shuichiro [2 ]
Rammelsberg, Peter [1 ]
Boehm, Sophia [1 ]
Schwindling, Franz Sebastian [3 ]
机构
[1] Heidelberg Univ Hosp, Dept Prosthodont, D-69120 Heidelberg, Germany
[2] Tokyo Dent Coll, Dept Removable Prosthodont & Gerodontol, Tokyo 1010061, Japan
[3] Med Univ Innsbruck, Dept Prosthet Dent, A-6020 Innsbruck, Austria
关键词
accuracy; fit; retention; cobalt-chromium; removable partial denture; selective laser melting; FITTING IMPLANT SUPERSTRUCTURES; FORCE; PROSTHESES; ACCURACY;
D O I
10.3390/jfb14080416
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To evaluate fit and retention of cobalt-chromium removable partial denture (RPD) frameworks fabricated with selective laser melting (SLM). Methods: Three types of framework for clasp-retained RPDs were virtually designed and fabricated using SLM (n = 30). For comparison, 30 additional frameworks were produced using conventional lost-wax casting. A biomechanical model was created, incorporating extracted teeth mounted on flexible metal posts. Using this model, horizontal constraint forces resulting from a misfit were measured using strain gauges, while vertical forces were not recorded. The constraint force components and resultant forces were determined for all abutment teeth, and the maximum retention force during RPD removal from the model was also assessed. For statistical evaluation, the two fabrication methods were analyzed by calculating the means and standard deviations. Results: The average horizontal constraint forces showed similar values for both fabrication methods (SLM: 3.5 +/- 1.0 N, casting: 3.4 +/- 1.6 N). The overall scatter of data for cast RPDs was greater compared to those fabricated using SLM, indicating a better reproducibility of the SLM process. With regard to retention, the intended retention force of 5-10 N per abutment tooth was not attained in one of the cast groups, while it was consistently achieved in all SLM groups. Conclusions: This in vitro study found that SLM is a promising option for the manufacture of cobalt-chromium RPD frameworks in terms of fit and retention.
引用
收藏
页数:14
相关论文
共 32 条
  • [11] Process parameter optimization for removable partial denture frameworks manufactured by selective laser melting
    Hwang, Seyeon
    An, Sangsup
    Robles, Ubaldo
    Rumpf, Raymond C.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (01) : 191 - 198
  • [12] Prognosis of double crown-retained removable dental prostheses compared with clasp-retained removable dental prostheses: A retrospective study
    Ishida, Keita
    Nogawa, Toshifumi
    Takayama, Yoshiyuki
    Saito, Masayasu
    Yokoyama, Atsuro
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (03) : 268 - 275
  • [13] Reduction in anisotropic response of corrosion properties of selective laser melted Co-Cr-Mo alloys by post-heat treatment
    Kajima, Yuka
    Takaichi, Atsushi
    Kittikundecha, Nuttaphon
    Htat, Hein Linn
    Cho, Hla Htoot Wai
    Tsutsumi, Yusuke
    Hanawa, Takao
    Wakabayashi, Noriyuki
    Yoneyama, Takayuki
    [J]. DENTAL MATERIALS, 2021, 37 (03) : E98 - E108
  • [14] Bone Adaptation Induced by Non-Passively Fitting Implant Superstructures: A Randomized Clinical Trial
    Karl, Matthias
    Taylor, Thomas D.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (02) : 369 - 375
  • [15] Karl M, 2009, INT J ORAL MAX IMPL, V24, P689
  • [16] Korber K H, 1983, ZWR, V92, P38
  • [17] Microstructure, mechanical properties, and retentive forces of cobalt-chromium removable partial denture frameworks fabricated by selective laser melting followed by heat treatment
    Lee, Wei-Fang
    Wang, Jia-Chang
    Hsu, Ching-Ying
    Peng, Pei-Wen
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01) : 115 - 121
  • [18] Biological complications of removable dental prostheses in the moderately reduced dentition: a systematic literature review
    Moldovan, Ovidiu
    Rudolph, Heike
    Luthardt, Ralph G.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2018, 22 (07) : 2439 - 2461
  • [19] Tactile sensitivity of vital and endodontically treated teeth
    Schneider, Birte-Juliane
    Freitag-Wolf, Sandra
    Kern, Matthias
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (11) : 1422 - 1427
  • [20] Internal porosities, retentive force, and survival of cobalt-chromium alloy clasps fabricated by selective laser-sintering
    Schweiger, Josef
    Gueth, Jan-Frederik
    Erdelt, Kurt-Juergen
    Edelhoff, Daniel
    Schubert, Oliver
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (02) : 210 - 216