Fit and Retention of Cobalt-Chromium Removable Partial Denture Frameworks Fabricated with Selective Laser Melting

被引:4
作者
Rues, Stefan [1 ]
Tasaka, Akinori [2 ]
Fleckenstein, Isabella [1 ]
Yamashita, Shuichiro [2 ]
Rammelsberg, Peter [1 ]
Boehm, Sophia [1 ]
Schwindling, Franz Sebastian [3 ]
机构
[1] Heidelberg Univ Hosp, Dept Prosthodont, D-69120 Heidelberg, Germany
[2] Tokyo Dent Coll, Dept Removable Prosthodont & Gerodontol, Tokyo 1010061, Japan
[3] Med Univ Innsbruck, Dept Prosthet Dent, A-6020 Innsbruck, Austria
关键词
accuracy; fit; retention; cobalt-chromium; removable partial denture; selective laser melting; FITTING IMPLANT SUPERSTRUCTURES; FORCE; PROSTHESES; ACCURACY;
D O I
10.3390/jfb14080416
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To evaluate fit and retention of cobalt-chromium removable partial denture (RPD) frameworks fabricated with selective laser melting (SLM). Methods: Three types of framework for clasp-retained RPDs were virtually designed and fabricated using SLM (n = 30). For comparison, 30 additional frameworks were produced using conventional lost-wax casting. A biomechanical model was created, incorporating extracted teeth mounted on flexible metal posts. Using this model, horizontal constraint forces resulting from a misfit were measured using strain gauges, while vertical forces were not recorded. The constraint force components and resultant forces were determined for all abutment teeth, and the maximum retention force during RPD removal from the model was also assessed. For statistical evaluation, the two fabrication methods were analyzed by calculating the means and standard deviations. Results: The average horizontal constraint forces showed similar values for both fabrication methods (SLM: 3.5 +/- 1.0 N, casting: 3.4 +/- 1.6 N). The overall scatter of data for cast RPDs was greater compared to those fabricated using SLM, indicating a better reproducibility of the SLM process. With regard to retention, the intended retention force of 5-10 N per abutment tooth was not attained in one of the cast groups, while it was consistently achieved in all SLM groups. Conclusions: This in vitro study found that SLM is a promising option for the manufacture of cobalt-chromium RPD frameworks in terms of fit and retention.
引用
收藏
页数:14
相关论文
共 32 条
  • [1] Accuracy of CAD-CAM-fabricated removable partial dentures
    Arnold, Christin
    Hey, Jeremias
    Schweyen, Ramona
    Setz, Juergen M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) : 586 - 592
  • [2] Bajunaid Salwa O, 2019, J Contemp Dent Pract, V20, P476
  • [3] Biomechanical Testing of Two-Unit Bridges and a Comparison of Replacement Retention Depending on a Cementation Medium, Replacement Position, and Gap Size
    Balogova, Alena Findrik
    Rajt'ukova, Viktoria
    Chromy, Lubos
    Somos, Andrej
    Izarikova, Gabriela
    Hudak, Radovan
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (04)
  • [4] 3D metal printing in dentistry: An in vitro biomechanical comparative study of two additive manufacturing technologies for full-arch implant-supported prostheses
    Barbin, Thais
    Veloso, Daniele Valente
    Silva, Leticia Del Rio
    Borges, Guilherme Almeida
    Camacho Presotto, Anna Gabriella
    Ricardo Barao, Valentim Adelino
    Mesquita, Marcelo Ferraz
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 108
  • [5] Becker H, 1983, Zahnarztl Prax, V34, P281
  • [6] Retention force and fatigue strength of overdenture attachment systems
    Botega, DM
    Mesquita, MF
    Henriques, GEP
    Vaz, LG
    [J]. JOURNAL OF ORAL REHABILITATION, 2004, 31 (09) : 884 - 889
  • [7] Adaptation of removable partial denture frameworks fabricated by selective laser melting
    Chen, Hu
    Li, Hong
    Zhao, Yijiao
    Zhang, Xinyue
    Wang, Yong
    Lyu, Peijun
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03) : 316 - 324
  • [8] Assessing the Accuracy of Casting and Additive Manufacturing Techniques for Fabrication of a Complete Palatal Coverage Metal Framework
    Forrester, Keaton
    Sheridan, Ryan
    Phoenix, Rodney D.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (07): : 811 - 817
  • [9] Gintaute Aiste, 2020, Swiss Dent J, V130, P229
  • [10] Noncontact intraoral measurement of force-related tooth mobility
    Goellner, Matthias
    Holst, Alexandra
    Berthold, Christine
    Schmitt, Johannes
    Wichmann, Manfred
    Holst, Stefan
    [J]. CLINICAL ORAL INVESTIGATIONS, 2010, 14 (05) : 551 - 557