Applications of scintillators in optical-fiber-based detectors

被引:18
作者
Watanabe, Kenichi [1 ]
机构
[1] Kyushu Univ, Dept Appl Quantum Phys & Nucl Engn, 744 Motooka, Nishi Ku, Fukuoka 8190395, Japan
关键词
ionizing radiation; scintillator; optical fiber; nuclear reactor physics experiment; radiation therapy; radiation resistance; ENERGY BEAM DOSIMETRY; NEUTRON DETECTOR; SENSOR; MONITOR; FLUX; LI;
D O I
10.35848/1347-4065/ac90a5
中图分类号
O59 [应用物理学];
学科分类号
摘要
This article presents the fundamentals and an overview of the optical-fiber-based scintillation detectors, which consist of a scintillator and an optical fiber light guide. This type of detector is preferentially used in special applications. In these applications, only a scintillator probe is placed in a severe environment, while a photodetector stays in a mild environment. Additionally, a detector should not disturb an irradiated field. As examples, applications in nuclear reactor physics experiments, medical uses, such as radiation therapies, and severe radiation conditions are reviewed.
引用
收藏
页数:8
相关论文
共 63 条
[1]   Dosimetric Characterization of an Inorganic Optical Fiber Sensor for External Beam Radiation Therapy [J].
Alharbi, Majed ;
Gillespie, Sean ;
Woulfe, Peter ;
McCavana, Pat ;
O'Keeffe, Sinead ;
Foley, Mark .
IEEE SENSORS JOURNAL, 2019, 19 (06) :2140-2147
[2]   A real-time method to simultaneously measure linear energy transfer and dose for proton therapy using organic scintillators [J].
Alsanea, Fahed ;
Therriault-Proulx, Francois ;
Sawakuchi, Gabriel ;
Beddar, Sam .
MEDICAL PHYSICS, 2018, 45 (04) :1782-1789
[3]   USE OF A GAMMA-RAY PINHOLE CAMERA FOR INVIVO STUDIES [J].
ANGER, HO .
NATURE, 1952, 170 (4318) :200-201
[4]   Plastic scintillation dosimetry and its application to radiotherapy [J].
Beddar, A. S. .
RADIATION MEASUREMENTS, 2006, 41 :S124-S133
[5]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[6]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[7]  
Birks J.B., 1964, THEORY PRACTICE SCIN
[8]   A systematic characterization of the low-energy photon response of plastic scintillation detectors [J].
Boivin, Jonathan ;
Beddar, Sam ;
Bonde, Chris ;
Schmidt, Daniel ;
Culberson, Wesley ;
Guillemette, Maxime ;
Beaulieu, Luc .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (15) :5569-5586
[9]   Temperature variations as a source of uncertainty in medical fiber-coupled organic plastic scintillator dosimetry [J].
Buranurak, S. ;
Andersen, C. E. ;
Beierholm, A. R. ;
Lindvold, L. R. .
RADIATION MEASUREMENTS, 2013, 56 :307-311
[10]   Characterization of the Exradin W1 scintillator for use in radiotherapy [J].
Carrasco, P. ;
Jornet, N. ;
Jordi, O. ;
Lizondo, M. ;
Latorre-Musoll, A. ;
Eudaldo, T. ;
Ruiz, A. ;
Ribas, M. .
MEDICAL PHYSICS, 2015, 42 (01) :297-304