Dielectrophoresis-assisted 65-GHz LC-oscillator array CMOS chips for label-free and sensitive detection of microorganism cells

被引:2
作者
Chen, Siyao [1 ,2 ]
Yamashige, Yoshihisa [1 ,2 ,3 ]
Mitsunaka, Takeshi [4 ]
Kondo, Naoshi [1 ]
Shiraga, Keiichiro [1 ,5 ]
Ogawa, Yuichi [1 ]
机构
[1] Kyoto Univ, Grad Sch Agr, Sakyo Ku, Kyoto 6068502, Japan
[2] Kyoto Univ, Distinguished Doctoral Program Platforms WISE, Yoshida Honmachi,Sakyo Ku, Kyoto 6068501, Japan
[3] Japan Soc Promot Sci, Tokyo, Japan
[4] Sharp Semicond Innovat Corp, Tenri, Nara 6328567, Japan
[5] Japan Sci & Technol Agcy, PRESTO, Kawaguchi 3320012, Japan
基金
日本学术振兴会;
关键词
Bacteria detection; CMOS; Dielectrophoresis; Lab-on-a-chip; LC oscillator; Sensitive measurement; HIGH-THROUGHPUT; IMPEDANCE DETECTION; BACTERIA DETECTION; CANCER-CELLS; SEPARATION; BIOSENSOR; QUANTIFICATION; MANIPULATION; IMMUNOSENSOR; PLATFORM;
D O I
10.1016/j.sna.2023.114286
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we propose a miniature, sensitive, and label-free method for detecting Escherichia coli (E. coli) and Saccharomyces cerevisiae (yeast) by using a complementary metal-oxide-semiconductor (CMOS) chip with die-lectrophoresis (DEP)-assisted LC-oscillator arrays. Each of the 62 x 24 arrayed sensor elements on the CMOS chip comprises a 65-GHz LC oscillator that senses the dielectric change due to the presence of the microorganisms. Given the non-uniform sensitivity of the LC oscillator, the DEP electrodes fabricated to be placed at the most sensitive position of the LC-oscillator were used to collect microorganisms and thereby enhance the measurement sensitivity. The AC electric field of DEP above 2 MHz interferes with the 65-GHz LC oscillator circuit in the designated vicinity. With appropriate DEP settings, each sensor element can achieve a limit of detection of two E. coli cells or one yeast cell. Quantitative enumeration reaches a single-cell resolution at small microorganism numbers. The results of this study confirmed that the novel approach of combining DEP technique and LC-oscillator array can perform high-sensitivity detection of microorganisms. Further, the realization of large-scale paralleled measurement makes the proposed CMOS biosensor a potential candidate as a rapid and low-cost lab-on-a-chip sensor for food inspection and clinical diagnosis.
引用
收藏
页数:10
相关论文
共 70 条
  • [1] Ameri A, 2019, 2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), P174, DOI [10.1109/TRANSDUCERS.2019.8808748, 10.1109/transducers.2019.8808748]
  • [2] Ameri A, 2019, SYMP VLSI CIRCUITS, pC314, DOI [10.23919/VLSIC.2019.8778194, 10.23919/vlsic.2019.8778194]
  • [3] Electrochemical immunosensors for Salmonella detection in food
    Araujo Melo, Airis Maria
    Alexandre, Dalila L.
    Furtado, Roselayne F.
    Borges, Maria F.
    Figueiredo, Evania Altina T.
    Biswas, Atanu
    Cheng, Huai N.
    Alves, Carlucio R.
    [J]. APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2016, 100 (12) : 5301 - 5312
  • [4] Babay M, 2019, EUR MICROW CONF, P168, DOI [10.23919/eumc.2019.8910746, 10.23919/EuMC.2019.8910746]
  • [5] Borgatti M, 2008, INT J MOL MED, V21, P3
  • [6] Detection of bacterial metabolism in lag-phase using impedance spectroscopy of agar-integrated 3D microelectrodes
    Butler, Derrick
    Goel, Nishit
    Goodnight, Lindsey
    Tadigadapa, Srinivas
    Ebrahimi, Aida
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 129 : 269 - 276
  • [7] Visual and high-throughput detection of cancer cells using a graphene oxide-based FRET aptasensing microfluidic chip
    Cao, Lili
    Cheng, Liwei
    Zhang, Zhengyong
    Wang, Yi
    Zhang, Xianxia
    Chen, Hui
    Liu, Baohong
    Zhang, Song
    Kong, Jilie
    [J]. LAB ON A CHIP, 2012, 12 (22) : 4864 - 4869
  • [8] High-density impedance-sensing array on complementary metal-oxide-semiconductor circuitry assisted by negative dielectrophoresis for single-cell-resolution measurement
    Chung, Jaehoon
    Chen, Yu
    Kim, Seong-Jin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 266 : 106 - 114
  • [9] Resonant dielectrophoresis and electrohydrodynamics for high-sensitivity impedance detection of whole-cell bacteria
    Couniot, Numa
    Francis, Laurent A.
    Flandre, Denis
    [J]. LAB ON A CHIP, 2015, 15 (15) : 3183 - 3191
  • [10] Isolation and concentration of bacteria from blood using microfluidic membraneless dialysis and dielectrophoresis
    D'Amico, L.
    Ajami, N. J.
    Adachi, J. A.
    Gascoynecde, P. R. C.
    Petrosino, J. F.
    [J]. LAB ON A CHIP, 2017, 17 (07) : 1340 - 1348