Statistical analysis of similarity of plasma parameters profiles at quasi-stationary stage of discharge in JET tokamak

被引:0
作者
Kukushkin, A. B. [1 ,2 ]
Sdvizhenskii, P. A. [1 ]
Flanagan, J. [3 ]
Kos, D. [3 ]
Neverov, V. S. [1 ]
Szepesi, G. [3 ]
Taylor, D. M. A. [3 ]
JET Contributors [4 ]
机构
[1] Natl Res Ctr, Kurchatov Inst, Moscow 123182, Russia
[2] Natl Res Nucl Univ MEPhI, Moscow 115409, Russia
[3] Culham Sci Ctr, CCFE, Abingdon OX14 3DB, England
[4] Culham Sci Ctr, EUROfus Consortium, JET, Abingdon OX14 3DB, England
基金
俄罗斯基础研究基金会;
关键词
tokamak; flat-top; plasma parameter profiles; statistical analysis; self-similarity;
D O I
10.1088/1361-6587/acd71e
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A statistical analysis is carried out of the similarity of profiles of plasma parameters: electron temperature T (e), density n (e), and pressure P (e), at the stage of quasi-stationary plasma current (the so called flat-top stage) of about 9000 discharges in the JET tokamak, among the discharges from #84458 to #99419 that covers almost the entire database of successful discharges in the JET ITER-like wall machine. For all these parameters, the existence of universal profiles is shown as functions of the normalized minor radius of the plasma column rho. The discharge universal profiles (DUPs) are obtained by dividing the space-time-dependent profile by its value at the center of the plasma column or by the space-averaged value of this parameter in the region rho <= rho (max) = 0.5-1, and subsequent averaging over time at the flat-top stage of each discharge. The machine universal profiles (MUPs) are obtained by averaging over time of flat-top stage of all discharges. It is shown that for 86% of the discharges, the time-averaged relative root-mean-square deviation of P (e) profile from the DUP is less than 20% at rho <= 0.8, and for the MUP, it is less than 17%. A similar picture is observed for the profiles of T (e) and n (e)/root T (e). An auxiliary heating, P (aux) > 1 MW or 10 MW, was present at, respectively, 44% and 21% of the total duration of the flat-top stage of discharges. It is shown that large, similar to 100% in magnitude, jumps of T (e) at rho = 0, caused by the switch-on of auxiliary heating, can be described with a similar to 20% accuracy by the jumps of the space-averaged temperature if the DUP is used to describe the stationary shape of the temperature spatial profile. The results obtained illustrate the degree of plasma self-organization in tokamaks.
引用
收藏
页数:15
相关论文
共 16 条
  • [1] Biskamp D., 1986, Comments on Plasma Physics and Controlled Fusion, V10, P165
  • [2] Coppi B., 1980, Comments on Plasma Physics and Controlled Fusion, V5, P261
  • [3] Dnestrovskij Yu N., 2002, IAEA FUS EN C LYON F, pp TH/P1
  • [4] Dnestrovskij Yu N., 2015, SELF ORG HOT PLASMAS
  • [5] Dnestrovskij Yu N., 2005, PLASMA PHYS REP+, V31, P529, DOI [10.1134/1.1992581, DOI 10.1134/1.1992581]
  • [6] Interpretation of tokamak self-consistent pressure profiles
    Dyabilin, K. S.
    Razumova, K. A.
    [J]. NUCLEAR FUSION, 2015, 55 (05)
  • [7] AXISYMMETRIC FINITE-BETA MINIMUM ENERGY EQUILIBRIA OF WEAKLY TOROIDAL DISCHARGES
    EDENSTRASSER, JW
    SCHUURMAN, W
    [J]. PHYSICS OF FLUIDS, 1983, 26 (02) : 500 - 507
  • [8] INVESTIGATION OF PLASMA-CONFINEMENT ON SOVIET TOKAMAKS
    ESIPTCHUK, YV
    RAZUMOVA, KA
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1986, 28 (9A) : 1253 - 1261
  • [9] Relaxed MHD states of a multiple region plasma
    Hole, M. J.
    Mills, R.
    Hudson, S. R.
    Dewar, R. L.
    [J]. NUCLEAR FUSION, 2009, 49 (06)
  • [10] THE TOKAMAK EQUILIBRIUM PROFILE
    HSU, JY
    CHU, MS
    [J]. PHYSICS OF FLUIDS, 1987, 30 (04) : 1221 - 1224