Novel biomimetic Prussian blue nanocubes-based biosensor for Tau-441 protein detection

被引:26
作者
Ben Hassine, Amira [1 ]
Raouafi, Noureddine [1 ]
Moreira, Felismina T. C. [2 ,3 ,4 ,5 ]
机构
[1] Univ Tunis El Manar, Tunis Fac Sci, Lab Analyt Chem & Electrochem, Sensors & Biosensors Grp, Tunis El Manar 2092, Tunisia
[2] ISEP, Polytech Inst, Sch Engn, BioMark Sensor Res, P-4249015 Porto, Portugal
[3] Minho Univ, Ctr Biol Engn, CEB, P-4710057 Braga, Portugal
[4] LABBELS Associate Lab, Guimaraes, P-4710057 Braga, Portugal
[5] Polytech Sch Porto, Sch Engn, R Dr Antonio Bernardino Almeida,431, P-4249015 Porto, Portugal
关键词
Alzheimer; Tau-441; Molecular imprinting polymer; Prussian blue nanocubes; Biosensor; Electrochemical; TAU-PROTEIN; CEREBROSPINAL-FLUID; HUMAN SERUM; BIOMARKER; POLYMERS; SENSOR;
D O I
10.1016/j.jpba.2023.115251
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tau protein is a promising biomarker for early diagnosis of Alzheimer's disease. Therefore, there is an urgent need to develop a simple and effective method for its detection. To this end, an innovative sensing device was developed using a carbon screen-printed electrode (C-SPE) decorated with graphene oxide/Prussian Blue nanocubes (GO/PBNCs) for the selective and sensitive determination of Tau-441 protein. The molecular imprinting polymer (MIP) was built on the GO/PBNCs/C-SPE by electropolymerizing 3-aminophenol (3-AMP) in the presence of the target protein using chronoamperometry, and the template was subsequently removed from the polymer matrix with oxalic acid. In parallel, a non-imprinted material (NIP) was also prepared in the absence of the target for comparison purposes. Scanning electron microscopy and transmission electron microscopy, were used to study the morphology of the modified electrode and electrochemical techniques were used to monitor the stepwise assembly of the sensor. Under optimized conditions, the sensing platform exhibited a linear range within 1.09 and 2.18 nmol/L and a detection limit of 0.01 pmol/L in spiked phosphate buffer solution (PBS). The MIP sensor showed minimal interference with uric acid and bovine albumin. The simplicity of production, affordable cost and promising performance make this sensor a potential strategic sensing platform for the detection of chemical and biological molecules.
引用
收藏
页数:7
相关论文
共 36 条
[1]   Diagnostic accuracy of cerebrospinal fluid biomarkers measured by chemiluminescent enzyme immunoassay for Alzheimer disease diagnosis [J].
Agnello, Luisa ;
Piccoli, Tommaso ;
Vidali, Matteo ;
Cuffaro, Luca ;
Lo Sasso, Bruna ;
Iacolino, Giorgia ;
Giglio, Vincenza Rosaria ;
Lupo, Federica ;
Alongi, Pierpaolo ;
Bivona, Giulia ;
Ciaccio, Marcello .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (04) :313-317
[2]   Voltammetric behavior of tiopronin on carbon paste electrode modified with nanocrystalline Fe50Ni50 alloys [J].
Baghayeri, Mehdi ;
Maleki, Behrooz ;
Zarghani, Rahele .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 44 :175-182
[3]   Novel Electrochemical Molecularly Imprinted Polymer-Based Biosensor for Tau Protein Detection [J].
Ben Hassine, Amira ;
Raouafi, Noureddine ;
Moreira, Felismina T. C. .
CHEMOSENSORS, 2021, 9 (09)
[4]   Molecular imprinting: perspectives and applications [J].
Chen, Lingxin ;
Wang, Xiaoyan ;
Lu, Wenhui ;
Wu, Xiaqing ;
Li, Jinhua .
CHEMICAL SOCIETY REVIEWS, 2016, 45 (08) :2137-2211
[5]   A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV) [J].
Dai, Yifan ;
Molazemhosseini, Alireza ;
Liu, Chung Chiun .
BIOSENSORS-BASEL, 2017, 7 (01)
[6]   Electrosynthesized molecularly imprinted polymers for protein recognition [J].
Erdossy, Julia ;
Horvath, Viola ;
Yarman, Aysu ;
Scheller, Frieder W. ;
Gyurcsanyi, Robert E. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 :179-190
[7]   Imprinting Technology in Electrochemical Biomimetic Sensors [J].
Frasco, Manuela F. ;
Truta, Liliana A. A. N. A. ;
Sales, M. Goreti F. ;
Moreira, Felismina T. C. .
SENSORS, 2017, 17 (03)
[8]   Sensing CA 15-3 in point-of-care by electropolymerizing O-phenylenediamine (oPDA) on Au-screen printed electrodes [J].
Gomes, Rui S. ;
Moreira, Felismina T. C. ;
Fernandes, Ruben ;
Sales, M. Goreti F. .
PLOS ONE, 2018, 13 (05)
[9]   Electrochemical biosensors -: Sensor principles and architectures [J].
Grieshaber, Dorothee ;
MacKenzie, Robert ;
Voeroes, Janos ;
Reimhult, Erik .
SENSORS, 2008, 8 (03) :1400-1458
[10]   Levels of nonphosphorylated and phosphorylated tau in cerebrospinal fluid of Alzheimer's disease patients - An ultrasensitive bienzyme-substrate-recycle enzyme-linked Immunosorbent assay [J].
Hu, YY ;
He, SS ;
Wang, XC ;
Duan, QH ;
Grundke-Iqbal, I ;
Iqbal, K ;
Wang, JZ .
AMERICAN JOURNAL OF PATHOLOGY, 2002, 160 (04) :1269-1278