Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis

被引:10
|
作者
Jiang, Jiabao [1 ]
Chen, Jialei [1 ]
Xing, Fei [1 ]
Liu, Hao [1 ]
Xiang, Zhou [1 ]
机构
[1] Sichuan Univ, West China Hosp, Orthoped Res Inst, Dept Orthoped, Chengdu, Sichuan, Peoples R China
关键词
Femoral neck system; Cannulated screw; Femoral neck fracture; Internal fixation; Systematic review; HIP; FIXATION; MULTICENTER; MANAGEMENT;
D O I
10.1186/s12891-023-06378-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundRecently, some studies on the efficacy of the femoral neck system (FNS) in treating femoral neck fractures (FNFs) have been published. Therefore, a systematic review was performed to clarify the efficacy and safety of FNS versus cannulated screws (CS) for the treatment of FNFs.MethodThe PubMed, EMBASE, and Cochrane databases were systematically searched for studies comparing FNS and CS fixations in FNFs. Intraoperative indicators, postoperative clinical indicators, postoperative complications, and postoperative scores were compared between the implants.ResultsA total of eight studies were included in the study, involving 448 FNFs patients. The results showed that patients in FNS group were significantly lower than the CS group in the number of X-ray exposures (WMD = -10.16; 95% CI, -11.44 to -8.88; P < 0.001; I-2 = 0%), fracture healing time (WMD = -1.54; 95% CI, -2.38 to -0.70; P < 0.001; I-2 = 92%), length of femoral neck shortening (WMD = -2.01; 95% CI, -3.11 to -0.91; P < 0.001; I-2 = 0%), femoral head necrosis (OR = 0.27; 95% CI, 0.08 to 0.83; P = 0.02; I-2 = 0%), implant failure/cutout (OR = 0.28; 95% CI, 0.10 to 0.82; P = 0.02; I-2 = 0%), and Visual Analog Scale Score (WMD = -1.27; 95% CI, -2.51 to -0.04; P = 0.04; I-2 = 91%). And the Harris Score was significantly higher in the FNS group than in the CS group (WMD = 4.15; 95% CI, 1.00 to 7.30; P = 0.01; I-2 = 89%).ConclusionsBased on this meta-analysis, FNS shows better clinical efficacy and safety in treating FNFs compared to CS. However, due to the limited quality and number of included studies and the high heterogeneity of the meta-analysis; large samples and multicenter RCTs are needed to confirm this conclusion in the future.Trial registrationPROSPERO CRD42021283646.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Internal Fixation Versus Hemiarthroplasty for Nondisplaced Femoral Neck Fractures: A Systematic Review and Meta-Analysis
    Sattari, Shahab Aldin
    Guilbault, Ryan
    MacMahon, Aoife
    Salem, Hytham S. S.
    Khanuja, Harpal S. S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (05) : E219 - E226
  • [42] Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients
    Hu, Huaijian
    Cheng, Jingbo
    Feng, Mingli
    Gao, Zhihua
    Wu, Jingwei
    Lu, Shibao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [43] Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients
    Huaijian Hu
    Jingbo Cheng
    Mingli Feng
    Zhihua Gao
    Jingwei Wu
    Shibao Lu
    Journal of Orthopaedic Surgery and Research, 16
  • [44] Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study
    Tang, Yunfeng
    Zhang, Zhen
    Wang, Limin
    Xiong, Wei
    Fang, Qian
    Wang, Guanglin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [45] Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study
    Yunfeng Tang
    Zhen Zhang
    Limin Wang
    Wei Xiong
    Qian Fang
    Guanglin Wang
    Journal of Orthopaedic Surgery and Research, 16
  • [46] Cannulated screws versus hemiarthroplasty for displaced intracapsular femoral neck fractures in demented patients
    van Dortmont, LMC
    Douw, CM
    van Breukelen, AMA
    Laurens, DR
    Mulder, PGH
    Wereldsma, JCJ
    van Vugt, AB
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 2000, 89 (02) : 132 - 137
  • [47] Internal Fixation Versus Arthroplasty for the Treatment of Nondisplaced Femoral Neck Fractures in the Elderly: A Systematic Review and Meta-Analysis
    Richards, John T.
    Overmann, Archie L.
    O'Hara, Nathan N.
    D'Alleyrand, Jean-Claude
    Slobogean, Gerard P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (01) : 42 - 48
  • [48] Femoral neck fractures in non-geriatric patients: femoral neck system versus cannulated cancellous screw
    Guy Romeo Kenmegne
    Chang Zou
    Yue Fang
    Xuanhong He
    Yixiang Lin
    Yijie Yin
    BMC Musculoskeletal Disorders, 24
  • [49] Femoral neck fractures in non-geriatric patients: femoral neck system versus cannulated cancellous screw
    Kenmegne, Guy Romeo
    Zou, Chang
    Fang, Yue
    He, Xuanhong
    Lin, Yixiang
    Yin, Yijie
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [50] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Yoram A. Weil
    Feras Qawasmi
    Meir Liebergall
    Rami Mosheiff
    Amal Khoury
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 661 - 667