Limited utility of adding 3T cervical spinal cord MRI to monitor disease activity in multiple sclerosis

被引:4
|
作者
Lim, Timothy Reynold U. [1 ]
Kumaran, Sunitha P. [1 ]
Suthiphosuwan, Suradech [1 ]
Espiritu, Adrian, I [2 ,3 ,4 ]
Jones, Ashley [2 ]
Lin, Amy Wei [1 ]
Oh, Jiwon [2 ,5 ]
Bharatha, Aditya [1 ,6 ]
机构
[1] Univ Toronto, St Michaels Hosp, Dept Med Imaging, Div Neuroradiol, Toronto, ON, Canada
[2] Univ Toronto, St Michaels Hosp, Dept Med, Div Neurol, Toronto, ON, Canada
[3] Univ Philippines Manila, Coll Med, Dept Neurosci, Manila, Philippines
[4] Univ Philippines Manila, Coll Med, Dept Clin Epidemiol, Manila, Philippines
[5] Johns Hopkins Univ, Dept Neurol, Baltimore, MD USA
[6] Univ Toronto, St Michaels Hosp, Dept Med Imaging, Div Neuroradiol, 30 Bond St, Toronto, ON M5B1W8, Canada
基金
美国国家卫生研究院;
关键词
Multiple sclerosis; MRI; spinal cord; disease monitoring; NEDA; NO EVIDENCE; LESIONS; RECOMMENDATIONS; GUIDELINE; BRAIN; MS;
D O I
10.1177/13524585241228426
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Performing routine brain magnetic resonance imaging (MRI) is widely accepted as the standard of care for disease monitoring in multiple sclerosis (MS), but the utility of performing routine spinal cord (SC) MRI for this purpose is still debatable. Objective: This study aimed to measure the frequency of new isolated cervical spinal cord lesions (CSLs) in people with MS (pwMS) undergoing routine brain and cervical SC-MRI for disease monitoring and determine the factors associated with the development of new CSLs and their prognostic value. Methods: We retrospectively identified 1576 pwMS who underwent follow-up 3T brain and cervical SC-MRI over a 9-month period. MRI was reviewed for the presence of new brain lesions (BLs) and CSLs. Clinical records were reviewed for interval relapses between sequential scans and subsequent clinical relapse and disability worsening after the follow-up MRI. Results: In 1285 pwMS (median interval: 13-14 months) who were clinically stable with respect to relapses, 73 (5.7%) had new CSLs, of which 49 (3.8%) had concomitant new BLs and 24 (1.9%) had new isolated CSLs only. New asymptomatic CSLs were associated with > 3 prior relapses (p = 0.04), no disease-modifying therapy (DMT) use (p = 0.048), and > 3 new BLs (p < 0.001); > 3 new BLs (OR: 7.11, 95% CI: 4.3-11.7, p < 0.001) remained independently associated with new CSLs on multivariable analysis. Having new asymptomatic CSLs was not independently associated with subsequent relapse or disability worsening after the follow-up MRI (median follow-up time of 26 months). Conclusion: Routine brain and cervical SC-MRI detected new isolated CSLs in only < 2% of clinically stable pwMS. Developing new asymptomatic CSLs was associated with concomitant new BLs and did not confer an independent increased risk of relapse or disability worsening. Performing SC-MRI may not be warranted for routine monitoring in most pwMS, and performing only brain MRI may be sufficient to capture the vast majority of clinically silent disease activity.
引用
收藏
页码:505 / 515
页数:11
相关论文
共 50 条
  • [31] Demyelinating lesions in the cervical cord in multiple sclerosis 10 years after onset of the disease. Correlation between MRI parameters and clinical course
    Bonek, Robert
    Orlicka, Katarzyna
    Maciejek, Zdzislaw
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2007, 41 (03) : 229 - 233
  • [32] Brain MRI Lesion Load at 1.5T and 3T versus Clinical Status in Multiple Sclerosis
    Stankiewicz, James M.
    Glanz, Bonnie I.
    Healy, Brian C.
    Arora, Ashish
    Neema, Mohit
    Benedict, Ralph H. B.
    Guss, Zachary D.
    Tauhid, Shahamat
    Buckle, Guy J.
    Houtchens, Maria K.
    Khoury, Samia J.
    Weiner, Howard L.
    Guttmann, Charles R. G.
    Bakshi, Rohit
    JOURNAL OF NEUROIMAGING, 2011, 21 (02) : e50 - e56
  • [33] Whole Brain Volume Measured from 1.5T versus 3T MRI in Healthy Subjects and Patients with Multiple Sclerosis
    Chu, Renxin
    Tauhid, Shahamat
    Glanz, Bonnie I.
    Healy, Brian C.
    Kim, Gloria
    Oommen, Vinit V.
    Khalid, Fariha
    Neema, Mohit
    Bakshi, Rohit
    JOURNAL OF NEUROIMAGING, 2016, 26 (01) : 62 - 67
  • [34] Quantification of Global Cerebral Atrophy in Multiple Sclerosis from 3T MRI Using SPM: The Role of Misclassification Errors
    Dell'Oglio, Elisa
    Ceccarelli, Antonia
    Glanz, Bonnie I.
    Healy, Brian C.
    Tauhid, Shahamat
    Arora, Ashish
    Saravanan, Nikila
    Bruha, Matthew J.
    Vartanian, Alexander V.
    Dupuy, Sheena L.
    Benedict, Ralph H. B.
    Bakshi, Rohit
    Neema, Mohit
    JOURNAL OF NEUROIMAGING, 2015, 25 (02) : 191 - 199
  • [35] Diffusion tensor imaging of the cervical spinal cord in healthy adult population: normative values and measurement reproducibility at 3T MRI
    Brander, Antti
    Koskinen, Eerika
    Luoto, Teemu M.
    Hakulinen, Ullamari
    Helminen, Mika
    Savilahti, Sirpa
    Ryymin, Pertti
    Dastidar, Prasun
    Ohman, Juha
    ACTA RADIOLOGICA, 2014, 55 (04) : 478 - 485
  • [36] Fast and Accurate Semi-Automated Segmentation Method of Spinal Cord MR Images at 3T Applied to the Construction of a Cervical Spinal Cord Template
    El Mendili, Mohamed-Mounir
    Chen, Raphael
    Tiret, Brice
    Villard, Noemie
    Trunet, Stephanie
    Pelegrini-Issac, Melanie
    Lehericy, Stephane
    Pradat, Pierre-Francois
    Benali, Habib
    PLOS ONE, 2015, 10 (03):
  • [37] T1-vs. T2-based MRI measures of spinal cord volume in healthy subjects and patients with multiple sclerosis
    Kim, Gloria
    Khalid, Fariha
    Oommen, Vinit V.
    Tauhid, Shahamat
    Chu, Renxin
    Horsfield, Mark A.
    Healy, Brian C.
    Bakshi, Rohit
    BMC NEUROLOGY, 2015, 15
  • [38] Pulse-Triggered DTI Sequence with Reduced FOV and Coronal Acquisition at 3T for the Assessment of the Cervical Spinal Cord in Patients with Myelitis
    Hodel, J.
    Besson, P.
    Outteryck, O.
    Zephir, H.
    Ducreux, D.
    Monnet, A.
    Chechin, D.
    Zins, M.
    Rodallec, M.
    Pruvo, J. P.
    Vermersch, P.
    Leclerc, X.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) : 676 - 682
  • [39] Detection of Spinal Cord Multiple Sclerosis Lesions Using a 3D-PSIR Sequence at 1.5 T
    Peters, Soenke
    Neves, Fernando Bueno
    Huhndorf, Monika
    Gaertner, Friederike
    Stuerner, Klarissa
    Jansen, Olav
    Ravesh, Mona Salehi
    CLINICAL NEURORADIOLOGY, 2024, 34 (02) : 403 - 410
  • [40] Quantitative magnetic resonance spectroscopy in the entire human cervical spinal cord and beyond at 3T
    Henning, Anke
    Schaer, Michael
    Kollias, Spyros S.
    Boesiger, Peter
    Dydak, Ulrike
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1250 - 1258